SOLICITATION NOTICE
16 -- Aircraft Pallet Storage System
- Notice Date
- 7/17/2023 11:43:20 AM
- Notice Type
- Solicitation
- NAICS
- 332999
— All Other Miscellaneous Fabricated Metal Product Manufacturing
- Contracting Office
- 11TH COAST GUARD DISTRICT OFFICE ALAMEDA CA 94501 USA
- ZIP Code
- 94501
- Solicitation Number
- 20290PR230000242
- Response Due
- 7/21/2023 9:00:00 PM
- Archive Date
- 08/06/2023
- Point of Contact
- Jared Osborne, Phone: 9166437669
- E-Mail Address
-
Jared.A.Osborne@uscg.mil
(Jared.A.Osborne@uscg.mil)
- Description
- STATEMENT OF WORK Aircraft Pallet Storage Rack Installation For Building 1106 or 1032 USCG Air Station Sacramento 1.0 GENERAL REQUIREMENTS 1.1 PROJECT DESCRIPTION The purpose of this statement of work (SOW) is to describe the specifications and scope of aircraft pallet storage system installation for Air Station Sacramento�s Hangar. The pallet rack system will provide proper organization of HC27J accessories. 1.1.1 Technical Point of Contact (POC): LT Kenneth F. Hunkus (916-643-7666) 1.2 LOCATION 1.2.1 Work to be conducted at USCG Air Station Sacramento. 6037 Price Ave McClellan, CA 95652 Building #1106 1.3 AIR STATION AND LOCAL REGULATIONS 1.3.1 The work site is on Government property. All rules and regulations issued by the Commanding Officer covering safety, vehicle operation, and sanitation must be always observed by the Contractor and his employees. 1.3.2 All personnel employed on site shall keep within the limits of the work and shall not enter any restricted area unless required or escort by a unit member. The Contractor�s equipment shall be conspicuously marked for identification. 1.3.3 The Contractor shall control its employee�s traffic on site. Parking for workers shall be at a suitable location as directed by the Technical POC. 1.3.4 The Contractor shall coordinate work with the technical POC to minimize any disruption to normal unit operations. 1.4 DAMAGE TO GOVERNMENT PROPERTY 1.4.1 Any damage caused to Government or private property shall be corrected at the Contractor�s expense. 1.5 SAFETY AND SECURITY 1.5.1 The Contractor shall provide all necessary safety equipment to protect the work site area. All work shall be performed in accordance with O.S.H.A. Safety standards to prevent injury to housing occupants, by-passers, or workforce. 1.5.2 Contractor shall comply with Federal and State of California safety and health regulations. When standards differ, the more stringent shall apply. All accidents and property damage shall be reported to the Technical POC. 1.5.3 The Contractor shall be responsible for the security of their material, tools, and equipment. The Government shall not be responsible for their loss. 1.5.4 The Contractor shall comply with all rules and regulations issued by the National Fire Protection Association covering the use and storage of flammable mixtures or material which might constitute a fire hazard. 2.0 EQUIPMENT 2.1 Contractor shall provide whatever equipment necessary to complete the inspection and service of unit boilers. 3.0 SCOPE OF WORK 3.1 Provide all equipment, and materials, to complete the installation of aircraft pallet rack system: (Install Optional) 1. 2 Shelves high, 5 shelves wide, anchored to concrete with ability to remove and reinstall in a separate location. 2. The bottom shelf of the rack must be capable of storing six pallets of the following dimensions: 88�x108�x12�. The shelf must be capable of having those pallets loaded and unloaded by forklift. 3. The top shelf of the rack must be capable of storing five aircraft pallets of the following dimensions: 88�x108�x60�. The rack must be capable of having those pallets loaded and unloaded by forklift. 4. Each shelf must be capable of supporting at minimum 5,000 pounds 5. Install aircraft pallet rack storage system in the following location: Southwest corner of the hangar building 1106 or southwest corner of building 1032 as directed by unit�s POC. 3.2 Delivery/Services shall be accomplished between the hours of 0800-1530, MondayFriday, not to include federal holidays except as designated by the contracting officer or official representative. 3.3 Contractor shall coordinate with the technical POC to schedule a date and time for delivery. 3.3.1 Project is to be completed within 07 days of the contract being awarded or as soon as parts arrive. 3.4 The government shall use a 100% surveillance method. Inspection of work shall be performed at the time the Contractor is at the site performing its services and prior to contractor leaving the site. 3.5 The Contractor shall remove all debris, rubbish, and hazardous waste from the job site. 3.6 The Contractor shall keep the Contracting Officer and /or technical POC fully informed on the daily progress of the work, from the start through completion of this inspection. 3.7 Unsatisfactory performance shall result in work being re-accomplished at no cost to the government. 3.8 It is the contractor�s responsibility to verify all measurements/dimensions listed above prior to submitting a quote/proposal. 3.9 Point of contact is LT Kenneth F. Hunkus (916-643-7666) ALL QUOTES MUST BE SENT ONLY TO�:� Jared.A.Osborne@uscg.mil (916) 643-7678 Christopher.A.Bahn@uscg.mil� 916 643 7674
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/26698f23eca342df8523ba0fae10d00c/view)
- Place of Performance
- Address: McClellan, CA 95652, USA
- Zip Code: 95652
- Country: USA
- Zip Code: 95652
- Record
- SN06751594-F 20230719/230717230052 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |