SOURCES SOUGHT
47 -- Sources Sought for BLDG 340 Scrubber Duct
- Notice Date
- 7/28/2023 12:10:51 PM
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- W6QK CCAD CONTR OFF CORPUS CHRISTI TX 78419-5260 USA
- ZIP Code
- 78419-5260
- Solicitation Number
- PANRSA-23-P-0000-012953
- Response Due
- 8/4/2023 1:30:00 PM
- Archive Date
- 08/19/2023
- Point of Contact
- Harold ""Jay"" Russell Jr., Phone: 3619617831, Dawyn M. Martinez
- E-Mail Address
-
harold.w.russell.civ@army.mil, dawyn.m.martinez.civ@army.mil
(harold.w.russell.civ@army.mil, dawyn.m.martinez.civ@army.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- The Army Contracting Command-Redstone Arsenal-Corpus Christi Army Depot(CCAD), Corpus Christi, Texas is issuing this sources sought to identify potential small business concerns having an interest and capability to supply the materials specified herein. Results of this market research will contribute to determining the method of procurement.� Based on responses to this sources sought notice/market research, this requirement may be set-aside for small businesses (in full or in part) or procured through full and open competition. All small business set-aside categories will be considered.� Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding submissions. THIS SOURCES SOUGHT IS FOR INFORMATIONAL PURPOSES ONLY.� THIS IS NOT A REQUEST FOR QUOTE (RFQ) TO BE SUBMITTED.� IT DOES NOT CONSTITUTE A SOLICITATION AND SHALL NOT BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT.� RESPONSES IN ANY FORM ARE NOT OFFERS AND THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT.� NO FUNDS ARE AVAILABLE TO PAY FOR PREPARATION OF RESPONSES TO THIS ANNOUNCEMENT.� ANY INFORMATION SUBMITTED BY RESPONDENTS IS STRICTLY VOLUNTARY. Background: Bldg 340 scrubber duct (vertical run from scrubber to exhaust fan) collapsed (sucked in) and is in need of replacement. This is adversely impacting Bldg 340 (Plating Shop) production operations and requires expedient attention and repair. It is felt that the duct section was not adequately designed for the application. It is believed that summer heat and exhaust fan suction led to its collapse. Duct is of UV protected polypropylene construction. Specification for Replacement Duct Section: 1) Polypropylene or other vendor recommended and CCAD approved material of construction which would be compatible with acidic or basic scrubber solutions. 2) Scrubber section material of construction shall be UV protected. 3) Scrubber duct section shall be designed to withstand or exceed twelve (12) inches wg of vacuum or otherwise reinforced to prevent a collapse from reoccurring. Duct reinforcement bands or other strengthening means may be employed as deemed prudent in the design. Mechanical Specifications: Replacement duct 42"" ID UVWPP; slip ring 42"" ID Scope of Work: 1) Provide all equipment and labor for removing and replacing damaged duct section. 2) CCAD shall provide replacement duct section. 3) Note: Bolt holes in flanges of new duct section would be drilled in the field to match existing mating flange.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/05214b51625a4a1e8914de6d0f17131e/view)
- Place of Performance
- Address: Corpus Christi, TX 78419, USA
- Zip Code: 78419
- Country: USA
- Zip Code: 78419
- Record
- SN06768846-F 20230730/230728230053 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |