SOURCES SOUGHT
65 -- Equipment, Radiofrequency Puncture Generator, Ann Arbor VAMC
- Notice Date
- 7/28/2023 11:42:21 AM
- Notice Type
- Sources Sought
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
- ZIP Code
- 45428
- Solicitation Number
- 36C25023Q0983
- Response Due
- 8/4/2023 9:00:00 AM
- Archive Date
- 09/03/2023
- Point of Contact
- Contract Specialist, James Howard
- E-Mail Address
-
james.howard3@va.gov
(james.howard3@va.gov)
- Awardee
- null
- Description
- This is a SOURCES SOUGHT only pertaining to brand name or equal item(s) for the Battle Creek VA Medical Center, Battle Creek, MI. Information collected during this Sources Sought may be used in a set aside. If a solicitation is issued, the Government will do so in accordance with the latest Federal Acquisition Circular (FAC). The North American Industry Classification System (NAICS) number is 339112. The NAICS size is 1,000 employees. Any contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and be able to be located through SBA - Dynamic Small Business Search. Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with in VetCert at Veteran Small Business Certification (sba.gov) as an SDVOSB or VOSB. Contractors that deem themselves capable of meeting the requirement shall provide the below information to James Howard, Contract Specialist, at james.howard3@va.gov no-later-than Friday, August 4, 2023 at 12:00PM, EDT, referencing 36C25023Q0983. Responses shall include: (1) Business Name and Address, (2) Contract Number items are covered under, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) SAM UEI and NAICS code (5) Business Size SMALL or LARGE (6) Type of Business: service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) Information for the product you would propose and which if any of the salient characteristics below it does not meet. (8) Where the proposed product is manufactured. (9) A concern that is not a manufacturer of the supply shall provide the manufacturers name and size standard and an authorized distributor letter. (10) If the concern is the manufacture and the sole distributor, please provide documentation to that effect. If the concern is the manufacturer and has authorized distributors, please provide a list of the authorized distributors as well. (11) Current lead time of equipment that will be proposed. Contractor must be registered with https://www.sam.gov To be considered SDVOSB/VOSB, must be registered in VetCert at Veteran Small Business Certification (sba.gov). FOB is Destination. Delivery is to: Ann Arbor VA Medical Center 2215 Fuller Rd Ann Arbor, MI 48105 REQUIREMENTS: Baylis (Boston Scientific) Radiofrequency Puncture Generator (RFP-100A) Required for Transeptal access procedures RF Energy: 468 kHz, Sinusoidal / Maximum output power of 50 W Delivery modes: Pulsed RF or Constant RF Duty Cycle: Durations from 300 or 1000 msĀ± 5 ms Count-Up Timer: Settable from 1-10 s (Device dependent) / Display resolution: 1 s Current Rating: 5.0 A, 50-60 Hz Input voltage: 100-240 VAC Dimensions: 11.25 W x 15.6 D x 7 H Weight: 20 lbs Power cord length: 10 ft Additional Accessories RFP-100A Foot Switch (RFA-FS) Duomode Cable (RFX-BAY-DUO)
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/a8e582d0188a4028b66acf5a3cadca0a/view)
- Place of Performance
- Address: Department of Veterans Affairs Ann Arbor VA Medical Center 2215 Fuller Rd, Ann Arbor 48105
- Zip Code: 48105
- Zip Code: 48105
- Record