SOURCES SOUGHT
66 -- Sources Sought - Accelerated Summa Sampler System
- Notice Date
- 8/7/2023 10:10:57 AM
- Notice Type
- Sources Sought
- Contracting Office
- FA2396 USAF AFMC AFRL PZL AFRL PZLE WRIGHT PATTERSON AFB OH 45433-7541 USA
- ZIP Code
- 45433-7541
- Solicitation Number
- SS-AFRL-PZLEQ-2023-0017
- Response Due
- 8/17/2023 1:00:00 PM
- Archive Date
- 09/01/2023
- Point of Contact
- Andrew Hertel, Chris Stokes
- E-Mail Address
-
andrew.hertel.3@us.af.mil, chris.stokes.1@us.af.mil
(andrew.hertel.3@us.af.mil, chris.stokes.1@us.af.mil)
- Description
- Sources Sought � Accelerated Summa Sampler System - Sources Sought Description: The Air Force Research Laboratory (AFRL) is performing market research for the requirement of Accelerated Summa Sampler System. This is a Sources Sought (SS) / Request for Information (RFI). This is not a pre-solicitation or solicitation or Request for Proposal (RFP) and is not to be construed as any commitment by the Government. This notice does not obligate the Government to award a contract and or pay for any bid and/or proposal preparation costs. The Government will not accept proposals at this time. This notice is not an offer by the Government to enter into a contract. Interested Small Business concerns must identify to the contracting officer their interest and capability to satisfy the Government's requirement by closing date listed. Responses will allow the Government to conduct an initial review of market capabilities in support of requirements identified in attached Statement of Work document. Submission Details:�All interested parties are encouraged to submit a response to this SS/RFI announcement. Responses should address the following questions: 1. Company name, cage code, address, point of contact, phone number, and email address. 2. Identification of whether the company is currently designated as a Small Business as defined in FAR Part 19.1 and the appropriate category (i.e. 8a, HubZone, etc.). 3. Company description of relevant capability and experience to provide the identified item. A brief history of the organization. 4. Company's potential teammates/subcontractors (if required to ensure success). 5. What, if any, risks or unknowns would hinder industries ability to meet the requirements? The Government encourages you to submit any additional comments or suggestions that you would like to share. Capability package responses and questions shall be sent electronically to the primary and/or alternate Points of Contact. Be advised that all correspondence sent via e-mail shall contain a subject line that reads �Accelerated Summa Sampler System.� Note that e-mail filters at Wright-Patterson AFB are designed to filter e-mails without subject lines or with suspicious subject lines or contents (i.e., .exe, or .zip files).� Therefore, if this subject line is not included, the e-mail may not get through the e-mail filters.� Also be advised that .zip or .exe files are not allowable attachments and may be deleted by the e-mail filters at Wright-Patterson AFB.� If sending attachments with e-mail, ensure only .PDF, .doc, docx, xls, or .xsls documents are sent.� The e-mail filter may delete any other form of attachments. Primary Point of Contact: Andrew Hertel - andrew.hertel.3@us.af.mil Alternate Point of Contact: Chris Stokes - chris.stokes.1@us.af.mil Requirements/Salient Characteristics:� This is a one-time purchase where the vendors shall provide an Accelerated Summa Sampler system with the below requirements: GC interface kit for Thermo, including GC cover Transfer line mounting bracket GC cable GC interface kit for Agilent, including GC cover Transfer line mounting bracket GC cable Installation bundle, comprising Minicontroller KVM switch 2-6L cans with evaluation standards Air Tox; TO14A/TO-15/TO-15A; Soil Gas Bundle containing 7200A turnkey pre-concentrator with SC flow path, 3 stage, with liquid nitrogen modules installed Loop injection valve, installed Diaphragm pump 5 m USB cable 4 inlet heated transfer line or canister autosampler Million Air Autosampler with 0.1cc sample/calibration standard loop and 0.25 cc internal standard loop Silonite valve option 4 5400 Heaters for 3.5 inch L x � inch adsorbent Perkin Elmer tubes, 120 V 10 500 mL vacuum bottles, deactivated with silonite coated valves Oven cleaning system to accommodate up to twelve 6L or 3.2L canisters and 40 MiniCans or Bottle-Vacs 3100D control module with MD pump control 6 L oven 36/12 position manifold with MQT fittings a molecular drag pump 2-stage pump SL2 cable humidifier 3100 Controller and instrument mounting bracket Precision static diluter system operating at 90-250 VAC with full Silonite-D flow path, all 6 channels installed, a 5 m USB cable, and Win XP/Win7 and Win10 control software 4700 Controller and instrument mounting bracket Thermal transfer system with new flow control including 4-station thermal transfer system for transferring contents of a thermal desorption tube into a 500 ml bottle-vac. 2 �Extra long trays for 1L, 1.4l, and 2L minicans, 12 position Microbalve Can sampler, including 5 um silonite screw-on filter, sealing o-ring, sapphire, 1/4ODx 0.08� IDx 1.6� SS tube, Female microvalve 1/4� face-sealing flowmate to male QT valve silonite-coated 6 position canister tray for use with 7650-M and 7650-L 10 systems 6 position 6L canister tray alignment tool for use with 6 pos 6L canister tray 2 OS/76xx 18 position long trays for non-cooled 500 ml bottle 1.4L Silonite coated MiniCan and coated True Seal Valve 4 Short tray alignment pins 4-day Installation and familiarization with per diem, airfare and travel time��
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/ea6bb77d523349fbbb6eed460d580228/view)
- Place of Performance
- Address: Wright Patterson AFB, OH 45433, USA
- Zip Code: 45433
- Country: USA
- Zip Code: 45433
- Record
- SN06780014-F 20230809/230807230056 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |