SOLICITATION NOTICE
61 -- Telecom Equipment
- Notice Date
- 8/9/2023 9:35:20 AM
- Notice Type
- Combined Synopsis/Solicitation
- Contracting Office
- 250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
- ZIP Code
- 45428
- Solicitation Number
- 36C25023Q1019
- Response Due
- 8/17/2023 1:30:00 PM
- Archive Date
- 10/16/2023
- Point of Contact
- Morgan Stein, Contract Specialist, Phone: 937-268-6511
- E-Mail Address
-
Morgan.Stein@va.gov
(Morgan.Stein@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Awardee
- null
- Description
- Attachment 1: Combined Synopsis-Solicitation for Commercial Products and Commercial Services Description This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-01. This solicitation is set-aside for: Total SDVOSB Set-Aside The associated North American Industrial Classification System (NAICS) code for this procurement is 335311, with a small business size standard of 800. The FSC/PSC is 6150. The Cincinnati VA Medical Center has a requirement for Telecon Equipment. All interested companies shall provide quotations for the following: Item # Description/Part Number* Qty Price Per Unit Total Amount EA-3013-C Monitored eConnect PDU; Black; Vertical 10 $ $ ZPDS-208V30 A-L21-4L21-20R-CR Zonit Power Distribution 1 $ $ ZPDS-208V60 A-HW-6L21-20R Zonit Power Distribution 1 $ $ 52-20/L21-20 R-L21-20P-072B 6FT User Attached L21-20 Extension Cord Utilizing 5C10 SOOW 5 $ $ 52-13/C14-C1 5-048B 6FT IEC60320 C14 C15 16awg SJT 105c 13A 250V Power Cord - BLACK 12 $ $ SUBTOTAL Brand Name Or Equal (BNOE) offers will be considered. BNOE offers must provide documentation that the alternate item is of the same form, fit, and function as the listed items and related services, and will not require any adjustments, and include the following salient characteristics: NEED: Ten (10) rack-mounted power distribution units Specs: Amperage 20A Input Voltage 120/208 VAC, three-phase Input Connection One (1) L21-20 Output Voltage 208 VAC, single-phase Output Connections Thirty (30) C13 and six (6) C19 Output branch circuit protection Three (3) x 2P 20A hydraulic magnetic breakers Monitoring Inputs/Outputs LCD screen with ethernet, USB and environmental sensor ports with IP and serial monitoring and IP consolidation for PDU linking Mounting Tool-less Orientation Vertical Size 70.5 inches (1,791 mm) height x 2.2 inches (56 mm) width x 2.2 inches (56 mm) depth Basis of design Chatsworth eConnect PDU EA-3013-C NEED: One (1) zone power distribution unit, 60A Specs: Amperage 60A Input Voltage 208 VAC, three-phase Input Connections Two (2) 10 foot power cords, four-wire and ground, to terminate in hardwire boxes Output Connections Six (6) L21-20R Output branch circuit protection Individual 20A circuit breakers Size 2RU, 19 inch rack-mountable Basis of design Zonit ZPDS-208V60A-HW-6L21-20R NEED: One (1) zone power distribution unit, 30A Specs: Amperage 30A Input Voltage 208 VAC, three-phase Input Connections Two (2) 10 foot power cords, four-wire and ground, to terminate in L21-30P plugs Output Connections Four (4) L21-20R and six (6) NEMA 5-20 Size 2RU, 19 inch rack-mountable Basis of design Zonit ZPDS-208V30A-L21 4L21-20R-CR NEED: Five (5) power cords Specs: Amperage 20A Input Voltage 208 VAC, three-phase Input Connection L21-20R Output Voltage 208 VAC, three-phase Output Connections L21-20P Length Six (6) feet NEED: Twelve (12) jumper power cords Specs: Amperage 13A Input Voltage 208 VAC Input Connection C14 Output Voltage 208 VAC Output Connections C15 Length Four (4) feet (1.22m) Basis of design Cisco Systems CAB-C15-CBN Inspection will be made upon delivery and installation. Premature breakage or failures will be reported to the company for quality control correction as well as for replacement. Alternate submission: Offerors submitting alternate items must provide technical information sufficient for a lay person to determine acceptability. Information will not be paid for by the government nor returned to the supplying party. The information will be used to determine product acceptability. Lack of sufficient information for our staff to determine product acceptability will result in a negative determination. Any quote will then be found non-responsiveness to the solicitation and the quote will not be considered. New Equipment ONLY; NO remanufactured, used/refurbished, or ""gray market"" items. All items must be covered by the manufacturer's warranty. No product in development shall be considered. Authorized dealers: Experienced firms only who are authorized dealers will be considered in addition to the original equipment manufacturer. A letter from the manufacturer stating your company is an authorized dealer for the line items must be in possession by the due date and be available for submission, if requested. Equipment items, and related services will be delivered, as required, to: Cincinnati VA Medical Center 3200 Vine St. Cincinnati, OH 45220-2213 Period of Performance Delivery shall be provided no later than 50 days after receipt of order (ARO). FOB: Destination. The full text of FAR provisions or clauses may be accessed electronically at http://acquisition.gov/comp/far/index.html. The following solicitation provisions apply to this acquisition: FAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://www.sam.gov/portal in accordance with FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services. If paragraph (j) of the provision is applicable, a written submission is required. The following contract clauses apply to this acquisition: FAR 52.212-4, Contract Terms and Conditions Commercial Items FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders The following subparagraphs of FAR 52.212-5 are applicable: 52.232-33, Payment by Electronic Funds Transfer System for Award Management (Oct 2018) (31 U.S.C. 3332). All quotes shall be sent to the Contracting Specialist, Morgan Stein at Morgan.Stein@va.gov Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13. Comparative evaluation is the side by side pairwise comparison of quotes based on factors (price, past performance, speed of delivery) resulting in a Contracting Officer decision for the quote most favorable to the Government. The award will be made to the response most advantageous and the BEST VALUE to the Government. Responses should contain your best terms, conditions. To facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows: ""The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition."" OR ""The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:"" Submission of your response shall be received not later than 16:30 PM Eastern Time on August 17, 2023. No phone calls please. Quoters shall list exception(s) and rationale for the exception(s), if any. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f). Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact for this solicitation; Morgan Stein, Contracting Specialist, NCO10 Contracting, Morgan.Stein@va.gov
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/a105d39e703d4d4d8e4ee0d3ffe8ef29/view)
- Place of Performance
- Address: Cincinnati VA Medical Center 3200 Vine St., Cincinnati, OH 45220-2213, USA
- Zip Code: 45220-2213
- Country: USA
- Zip Code: 45220-2213
- Record
- SN06783742-F 20230811/230809230054 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |