SOLICITATION NOTICE
Z -- Solicitation for Base-Wide Fire Alarm Transmission System
- Notice Date
- 8/21/2023 8:28:03 AM
- Notice Type
- Solicitation
- Contracting Office
- W6QK ACC-APG NATICK NATICK MA 01760-5011 USA
- ZIP Code
- 01760-5011
- Solicitation Number
- W911QY-23-R-1021
- Response Due
- 8/31/2023 11:00:00 AM
- Archive Date
- 09/15/2023
- Point of Contact
- Alexander M. Ponusky, Brandon Rivett
- E-Mail Address
-
alexander.m.ponusky.civ@army.mil, brandon.j.rivett.civ@army.mil
(alexander.m.ponusky.civ@army.mil, brandon.j.rivett.civ@army.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- AMENDMENT 1: Summary of Changes � W911QY-23-R-1021 Amendment 1 TE-01 � Design Requirements Updated Section 1.3.9.11 added building 65 Sections 1.3.6.4.15, 1.3.2.2, and 1.3.2.4 changed to reference TE-08 Design After Award Table 1.3.9-1 Notes added building 65 TE-08 Design After Award Added This document has been added to the Solicitation, and can be found under W911QY-23-R-1021, 1442 Solicitation Document. Contractor Q&A Added Answers from pre-Solicitation Notice and post-Site-Visit have been provided via Q&A Excel Document (see �20230809 � FA Transmission Bidder Q�s.xlsx�). Appendix B, NSSC FACP Locations Drawing Updated Appendix B has been updated to include building 65. External attachments 10, 11, and 12 have been renamed 11, 12, and 13 to allow for inclusion of TE-08. Redacted Justification and Approval (J&A) added for AES Equipment requirement. ORIGINAL SOLICITATION: This notice serves as formal Request for Proposal (RFP) from the Natick Contracting Division, for a base-wide fire alarm transmission system, with design-build construction and installation.� The purpose of this project is to provide Soldier Systems Center at Natick, Massachusetts, a reliable and code compliant means of transmitting fire alarm signals from existing fire alarm systems located in individual buildings, to a central receiving station located in Building 1. Currently, Natick uses a fiber optic cable loop to connect their Simplex fire alarm panels to the existing Simplex central receiver. This loop is not fully functional; there are five (5) legs in the loop that are non-functioning and unable to transmit, and there are four (4) building fire alarm panels which have not yet been connected to the loop. The Contractor must design and install a radio transceiver system that consist of transmitter panels and antennae at each building and central- station receiving equipment in Building 1. This system must be totally independent of the existing system and constructed in parallel without affecting the existing system�s operation. The existing Simplex receiving equipment and fiber optic cabling/equipment must not be demolished until the new radio system is operational and formal acceptance testing is complete.� The Government has determined that this acquisition will be set-aside 100% for small business concerns, with a single, Firm Fixed Price contract being issued. The Disclosure of Magnitude is estimated between $1M and $5M for this effort. The North American Industrial Classification System Code (NAICS code) is 236220 - Commercial and Institutional Building Construction, with a small business size standard of $45.0 Million. This announcement serves as formal solicitation associated with this effort - please see the supporting documentation provided with this notice for additional details. A site-visit is scheduled for 8 August 2023 @ 10am EST. All questions pertaining to the site-visit and solicitation are due by 2pm EST on 22 August 2023. Please refer to the formal solicitation in the attachments for other details. �
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/6a0d60457b2c4989b343d715ef9b0dc4/view)
- Place of Performance
- Address: Natick, MA 01760, USA
- Zip Code: 01760
- Country: USA
- Zip Code: 01760
- Record
- SN06799495-F 20230823/230821230052 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |