Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF OCTOBER 14, 2023 SAM #7991
SOURCES SOUGHT

H -- Medical Gas Annual Inspection

Notice Date
10/12/2023 10:25:10 AM
 
Notice Type
Sources Sought
 
NAICS
541350 — Building Inspection Services
 
Contracting Office
NETWORK CONTRACT OFFICE 19 (36C259) Greenwood Village CO 80111 USA
 
ZIP Code
80111
 
Solicitation Number
36C25924Q0019
 
Response Due
10/19/2023 8:00:00 AM
 
Archive Date
01/17/2024
 
Point of Contact
Tiffani Perkins, Contract Specialist, Phone: 918-577-3261
 
E-Mail Address
tiffani.perkins@va.gov
(tiffani.perkins@va.gov)
 
Awardee
null
 
Description
Last Updated: 2/22/2023 Last Updated: 2/22/2023 Oklahoma City Veterans Affairs Health Care System (OKC VA HCS) Performance Work Statement (PWS) Annual Medical Gas Inspection & Certification Service GENERAL: This project is for a contractor to provide medical gas inspection and certification services in accordance with NFPA 99, Health Care Facilities Code, current edition as well as the terms and conditions stated within this SOW annually for the Oklahoma City VA Health Care System, Oklahoma City, Oklahoma. The contractor is fully responsible for verifying and validating all information contained within this statement of work. Contractor must fully evaluate the condition of the existing structures and verify the current condition of the project site. All measurements/quantities provided in this document are approximate and are to be used for reference only. The contractor will be responsible for taking on-site measurements and verifying all quantities and distances. All materials/fasteners/etc. must be new and provided by the contractor unless otherwise specified. The contractor shall abide by all Safety, Security and Infection Control Policies and Procedures of the Oklahoma City VA HCS. VA facilities are tobacco free. No smoking is permitted on VA property. The contractor is responsible for their subcontractor s compliance with this policy. All work must conform to, and comply with, the latest edition/version of ALL applicable VA, federal, state, and local laws, rules, regulations, codes, and standards. BACKGROUND: This facility is approximately 1,000,000 square feet with 10 floors containing the equipment and outlets to be inspected and certified. All work will be performed within the facility. The medical gas system is comprised of: 1) 2 Master Alarm Panels Amico Medical Gas Alarms monitoring: Oxygen Primary Liquid Level Low Oxygen Secondary Liquid Low Head Pressure Oxygen Secondary Liquid Supply In Use Oxygen Secondary Liquid Low Head Pressure Oxygen Line Pressure High Oxygen Line Pressure Low In House Oxygen Emergency Reserve Cylinder in Use In House Oxygen Emergency Reserve Cylinder, Low Nitrous Oxide Reserve Cylinders in Use Nitrous Oxide Line Pressure High Nitrous Oxide Line Pressure Low Nitrogen Reserve Cylinders in Use Nitrogen Line Pressure High xiv. Nitrogen Line Pressure Low xv. Carbon Monoxide Level High Medical Air High Dew Point Medical Air Line Pressure High Medical Air Line Pressure Low Medical Air Compressor Maintenance Required Medical Vacuum Low Medical Air Line Pressure Low Medical Air Compressor High Temp Shutdown Medical Air High Dew Point Medical Air Lag Compressor in Use Medical Air Line Pressure High Carbon Monoxide Level High Oxygen Manifold Western Enterprises, Model FHM2-9-12V Medical Air PowerEx, Model MSH05044KS 6 Medical Air Dryer PowerEx, Model PMD71000AJ - 2 Medical Air PowerEx, Model MSQ05055428364 4 Medical Air Dryer PowerEx, Model MDD050850 2 Nitrous Oxide Manifold Western Innovator, Model WMS-13-37 Nitrogen Manifold Amico Corporation Oxygen Outlets 577 Medical Air Outlets 425 Medical Vacuum Outlets 630 Nitrous Oxide Outlets 36 Nitrogen Outlets 50 Waste Anesthetic Gases - 15 STATEMENT OF WORK: The contractor shall provide supervision, manpower, and materials to conduct a medical gas inspection and certification services in accordance with NFPA 99, Health Care Facilities Code. Contractor shall ensure each requirement listed in this PWS is satisfied and that constraints are honored and respected. If the contractor has any conflicts or challenges with these, they should consult the COR or CO. Contractor shall furnish all contract oversight, management, technically trained personnel, labor, equipment, tools, materials, supplies, insurances, and transportations necessary to provide scheduled Medical Gas Inspection and Certification Services If the contractor detects that any Government equipment or component being inspected under the contract is in need of reconditioning, repair, replacement (or disposal), details shall be submitted in writing to the COR. The Contractor shall not undertake or perform any reconditioning, repair, or replacement of equipment without prior authorization from the COR. The contractor shall provide the COR a copy of NITC Medical Gas Verifier 6030 licenses, required for person/people performing the services in this SOW prior to the conducting inspections. Either a paper or electronic version which may be emailed must be provided within: 15 business days of contract award and 15 business days after any contract option year awards The inspector shall carry the license with him/her during the entire duration of the inspection. The Contractor must provide the COR with certification attesting that all gauging and measurement equipment used to check and calibrate the subject items of equipment has been calibrated either according to the manufacturer s specifications or within the last twelve months against a standard that is traceable to the National Bureau of Standards. Such certification shall be provided with the service report submitted. The contractor shall provide the COR written confirmation that the Contractor has adequate insurance protection against negligent work and other forms of liability. The nature and level of protection must be acceptable to this VA. Either a paper version or emailed version must be provided to the COR within: 15 business days of contract award and 15 business days after any contract option year awards The contractor shall immediately report to the COR on all safety or operational related deficiencies during the inspection. The Contractor shall provide the COR with a Service Report detailing all tests performed, all findings, and all recommendations. The Service Report is to be signed and dated by designated Contractor POC and given to the COR within two weeks of performing the Inspection Service. The Service Report is to be submitted by email to the COR in addition to a printed copy. Contractor shall provide a statement describing their policy for charging of any additional fees due to rescheduling if equipment is not available at the time of the approved scheduled service call. Contractor shall contact the COR upon completion of inspection IMPORTANT NOTE: This Sources Sought is for information only (to determine the socioeconomic status of interested companies). No award will be made off of this posting. LIMITATIONS OF SUBCONTRACTING: The Limitations of Subcontracting may or may not apply to a resulting solicitation from this Market Research. Vendors are advised to familiarize themselves with Federal Acquisition Regulation parts 19.505(a)(2) and 19.505(b)(1) as it pertains to subcontracting limitations. Vendors are also advised to familiarize themselves with 13 CFR 125.6 and the penalties described in this regulation. Please communicate via e-mail to tiffani.perkins@va.gov by COB 10/19/2023 as to your company s interest and ability to perform service per this brief Scope of Work. If interested, please provide the following: Please state your company s business size as related to NAICS code 541350 As per the Limitations of Subcontracting: (see FAR 19.505) As Primary Contractor: what % of Total Contract Value will you retain? If using a Subcontractor: what % of Total Contract Value will go to them? Please provide SAMs Unique Entity Identifier number If you have an FSS/GSA contract that includes this service Provide FSS/GSA contract number if applicable   In order for you company s information to be counted in relation to this Market Research all above questions must be answered.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/8347557c93af46fb8d8750eaf56c1d82/view)
 
Place of Performance
Address: Department of Veterans Affairs Oklahoma City VA Health Care System 921 NE 13th St, Oklahoma City 73104
Zip Code: 73104
 
Record
SN06858689-F 20231014/231012230052 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.