Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 01, 2023 SAM #8009
SPECIAL NOTICE

66 -- DPG Julabo Equipment

Notice Date
10/30/2023 7:23:33 AM
 
Notice Type
Justification
 
Contracting Office
W6QM MICC-DUGWAY PROV GRD DUGWAY UT 84022-5000 USA
 
ZIP Code
84022-5000
 
Solicitation Number
W911S6-24-P-0001
 
Archive Date
11/29/2023
 
Point of Contact
Mark Pratt, Phone: 4358312094
 
E-Mail Address
mark.s.pratt4.civ@army.mil
(mark.s.pratt4.civ@army.mil)
 
Award Number
W911S6-24-P-0001
 
Award Date
10/05/2024
 
Description
Purchase of 4 Presto A85 208-230V/3PPE/60Hz Highly Dynamic Temperature Control Systems with 1-year warranties for each, and 9 Magio MS-100F 115V/60Hz Refrigerated/Heating Circulator with 1-year warranties for each. On September 01, 2023, a broken water line caused flooding inside the Closed System Chamber (CSC) at the Bushnell Materiel Test Facility (BMTF) which houses three test fixtures for the West Desert Test Center. Approximately 4600 gallons of water filled the CSC covering everything on the chamber floor. Thirteen Julabo temperature control systems were exposed to 12 inches of water. The smaller temperature control systems were nearly completely submerged. After cleaning the flood in the CSC, each temperature control system was inspected for damages. Noticeable corrosion was observed on the electrical component boards inside the temperature control systems. None of the units were functional. With up coming tests set to begin the first part of December, it is vital that the proper temperature control systems are installed and programmed within the current system to function properly. If the temperature control systems are not in place, the test fixtures will not function as designed and the temperature/humidity requirements for the upcoming tests will not be met. The Chemical Test Division has made great efforts to standardize the systems on each test fixture to cut costs and increase interoperability of test fixtures. The current test fixtures use Julabo temperature control systems for fixture temperature and humidity control. Each temperature control systems are remotely controlled and operated by the test fixture control software. Replacing the temperature control systems with that of another vendor would require additional work to reprogram the test fixture control software. This would require additional time and money to accomplish and would result in falling behind in schedule and costing more money to reprogram the fixture control software.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/22e1fdec251644d4b04e0bd3a17b886d/view)
 
Record
SN06870851-F 20231101/231030230044 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers