Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 10, 2023 SAM #8018
SOLICITATION NOTICE

20 -- USCGC BISCAYNE BAY COIL REPLACEMENT

Notice Date
11/8/2023 4:29:48 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
SFLC PROCUREMENT BRANCH 2(00085) ALAMEDA CA 94501 USA
 
ZIP Code
94501
 
Solicitation Number
70Z08524Q00512
 
Response Due
11/17/2023 8:00:00 AM
 
Archive Date
11/17/2023
 
Point of Contact
ERIC FOSTER, Phone: 5104375431, Nathan Damon, Phone: 7573342691
 
E-Mail Address
ERIC.T.FOSTER@USCG.MIL, Nathan.S.Damon@uscg.mil
(ERIC.T.FOSTER@USCG.MIL, Nathan.S.Damon@uscg.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z0-8524-Q-00512 and is issued as a request for quotations (RFQ). This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a total small business set aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be�received on/before 0800am Pacific Time, Nov 18th, 2023, and will be reviewed by the Government. �� The United States Coast Guard Surface Force Logistics Center has a requirement for the following: The CTR shall provide: �TECHNICAL SERVICES FOR COIL REPLACEMENT USCGC BISCAYNE BAY Background.� Two boiler heater coils replace in fan space. Scope. The scope of this work is on the USCGC BISCAYNE BAY and consists of: There are two �� in copper fittings on each unit that need to be sweated in. The units are bolted in-line with the air ducting and have an electric pre-heater attached to each unit. Ships force would be able to unwire and tag-out the electric units as an interference. The major restrictive aspect for this job is its location in the fan space, the overhead is 45� and it is accessed via a 25�x30� door. After both units are installed approximately 230 gallons of boiler water will need to be removed and replaced with Dow Frost HD Glycol 94%. We have the procedures for the boiler water replacement provided by Coast Guard Yard below. Please let me know if there is anything else that I can provide to better outline the scope of work for this project. Objective. �The objective of this requirement is to Remove and renew the 2 coils and return the system to fully functional. Tasks. The contractor shall Drain the entire boiler system completely, using the drain valves located on the bottom of each boiler where the relief valve ties into. Once that is complete, secure those two valves so the Dow frost doesn�t empty into the bilge. Next, there should be a low point drain located in the pilot house, use that for your fill point. We use 2ea 55gal barrels of Dow frost and the system holds about 230 gals, just a FYI. Once you add the Dow frost I use a garden hose to fill the system back up because you get more PSI from shore tie versus through the backflow preventer which is only set at 14 PSI. I tie the garden hose into the low point drain in the E/R on the supply side off of the 3� trunk line that goes into Aux space. I then use the pilot house and aft fan room as the two high points to bleed all of the air out (garden hose to a bucket). Once everything is filled and topped off just jog the one recirc pump in E/R for about 5 sec clips 15/20 times and that allows all the air to bleed out through the auto air vents located throughout the entire system. DO NOT, run them for long periods of time reasoning being it just makes it harder to get the air out of the system. Lastly once that is complete everything should be satisfied and running smoothly. Government furnished property.� Two coils to be installed .If further GFP is required, it will be incorporated via contract modification. Security Requirement. Base access is required.� Vendor shall have a valid driver�s license and show identification.� Cutter personnel will make arrangements to ensure contractor has access to base. Place of performance- Cutter's home pier, USCGC Biscayne Bay 1075 Huron St, St. Ignace, Mi. 49781 906-643-6437 � Ship 906-630-5747 � Ship Cell Period of performance- Start 20 NOV, 2021 Questions and quotes shall be emailed to Eric.T.Foster@uscg.mil and Nathan.S.Damon@uscg.mil. Contractors are responsible for verifying receipt of quotes. INTERESTED VENDORS PLEASE SIGN AN OFFICIAL QUOTE WITH A SAM.GOV REGISTERED DUNS NUMBER AND EMAIL TO Eric.T.Foster@USCG.MIL and Nathan.S.Damon@uscg.mil.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/92b86bb98e02445faa4e7e3d29366db4/view)
 
Place of Performance
Address: Saint Ignace, MI 49781, USA
Zip Code: 49781
Country: USA
 
Record
SN06879765-F 20231110/231108230057 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.