Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 17, 2023 SAM #8025
SOLICITATION NOTICE

Y -- B-21 Weapons Generation Facility - Site F (WGF-F)

Notice Date
11/15/2023 8:52:21 AM
 
Notice Type
Solicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
W071 ENDIST OMAHA OMAHA NE 68102-4901 USA
 
ZIP Code
68102-4901
 
Solicitation Number
W9128F23R0017
 
Response Due
11/29/2023 12:00:00 PM
 
Archive Date
11/14/2024
 
Point of Contact
Shawn Adkins, Phone: 4029952091, Jeffrey Wyant, Phone: 4029952071
 
E-Mail Address
shawn.a.adkins@usace.army.mil, jeffrey.w.wyant@usace.army.mil
(shawn.a.adkins@usace.army.mil, jeffrey.w.wyant@usace.army.mil)
 
Awardee
null
 
Description
****Amendment 0007**** Extends the proposal due date to 29 November 2023 and updates the acceptance period to 29 December 2023.****Amendment 0006**** Updates SPECS/Drawings and removes option CLIN 0008 from the solicitation. ****Amendment 0005**** Updates SPECS/Drawings and adds instructions to obtain FIO documents. ****Amendment 0004**** Updates to SPECS/Drawings and extends the proposal due date to 31 August 2023.****Amendment 0003**** Updates to SPECS/Drawings, as well as updated WD SD20230027 Building. Proposal due date remains 18 August 2023.****Amendment 0002 - Requesting Volume II proposals.***** Construct a 52,210 sq ft Weapons Generation Facility (WGF) that is a hardened facility within a protective zone, with consolidated storage, maintenance, inspection, and administrative functions using best practices from similar Department of the Navy and Department of Energy facilities currently in use. Project will construct a fire suppression system, all utilities, pavements, communication, site improvements, Security Forces Fire Team Facility (F2F), Entry Control Point (ECP)/Shelter and associated support facilities to provide a complete and useable facility. Overhead bridge cranes will be constructed for maintenance purposes in each maintenance bay. All construction will meet requirements for essential facility system nuclear design certification. The project will comply with all applicable DoD, Air Force, and base design standards. The project will use local materials and construction techniques where cost effective. The Contractor must design facilities as permanent construction in accordance with the DoD Unified Facilities Criteria (UFC) 1-200-01, General Building Requirements and UFC 1-200-02, High Performance and Sustainable Building Requirements. This project will comply with DoD antiterrorism/force protection requirements per UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings and include cybersecurity measures per UFC 4-010-06, Cybersecurity of Facility-Related Control Systems.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/102aa7c37eb24a4baef78881112b9702/view)
 
Record
SN06885911-F 20231117/231115230055 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.