Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 02, 2023 SAM #8040
SOURCES SOUGHT

W -- FY24 Excimer Laser System (Base plus 2 option year)

Notice Date
11/30/2023 11:05:40 AM
 
Notice Type
Sources Sought
 
NAICS
532490 — Other Commercial and Industrial Machinery and Equipment Rental and Leasing
 
Contracting Office
242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
 
ZIP Code
12208
 
Solicitation Number
36C24224Q0150
 
Response Due
12/7/2023 12:00:00 PM
 
Archive Date
02/05/2024
 
Point of Contact
Charles Collins, Contracting Officer, Phone: (518)626-7200
 
E-Mail Address
Charles.Collins@va.gov
(Charles.Collins@va.gov)
 
Awardee
null
 
Description
Sources Sought Notice The Department of Veterans Affairs Network Contracting Office 2 is issuing this Sources Sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support this requirement for Lease of the Excimer Laser System at the VA NYHHS Manhattan Campus Surgical Service 423 East 23nd Street New York, NY 10010. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 532490. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. STATEMENT OF WORK STATEMENT OF WORK FOR EXCIMER LASER RENTAL Introduction/Background The VA New York Harbor Healthcare System is dedicated to providing quality health care and security to veterans using the abilities of all employees supported by our commitment to education and research. The Excimer Laser System is used to extract infected pacer leads as an alternative to sternotomy and exploratory cardiotomy. Philips Spectranetics manufacture and markets the only Excimer Laser System approved in the United States for use in minimally invasive interventional procedures within the cardiovascular system. The Philips Spectranetics CVX-300 excimer laser in conjunction with proprietary optical fiber catheters is the only excimer laser system approved for use in the removal of cardiac pacemaker and defibrillator leads. An excimer laser produces pulsed bursts of ultraviolet (UV) light energy that are capable of vaporizing plaque and calcium into tiny particles, the majority of which are smaller than a red blood cell, that are easily absorbed into the blood stream. This energy is transmitted along flexiglass fibers encased in catheters, which can be passed through arteries and veins. The UV light energy is then focused on the blockages that need to be treated. The Excimer CV Laser is currently on site at the VA NY Harbor Healthcare System. Objectives The VA NYHHS Manhattan Campus is requesting a base year plus 2 option year, flat-rate rental agreement for the Philips Spectranetics CVX-300 excimer laser for the removal of cardiac pacemaker and defibrillator leads. Requirements The Phillips/Spectranetics LASER system (and GlideLight/CavaClear extraction sheaths) is the only non-mechanical option for transvenous lead extraction, IVC filters, and other chronic foreign bodies.  This is the only laser atherectomy option available for patients with large thrombus burden during acute myocardial infarction and patients with calcified disease behind acutely placed coronary stents. This equipment is required for coronaries and peripheral vascular cases as well as devise extraction there are no other alternatives. The excimer laser is a pulsed laser with the following specifications: Active medium: XeCI Wavelength: 308NM Catheter Output Fluence: 30-80 mJ/mm Repetition Rate Range: 25 80 Hz Pulse Width: 125-200 ns, FWHM Weight: 560 lbs/295 kg Length: 49 in/ 125 cm Height: 35 in/ 89 cm- unit 7-9 in/ 18-2 cm control panel Width: 25 in/ 62 cm Power Requirements: 200-230V ~ Single Phase 50/60 Hz 16 Amp Environmental Specifications Operating Temperature: 12 C to 30 C (54 F to 86 F) Storage temperature: 0 degrees C to 60 degrees C (32 F to 140 F) Operating Humidity: 5 to 95% relative humidity, non-condensing Storage Humidity: 5 to 95% relative humidity, non-condensing System footswitch is IPX8 rated Accessories: power cord, footswitch, interlock plug, safety glasses and Spectranetics approved fiber optic catheters Period of performance: Base year plus two (2) option years Other Requirements: The vendor shall be responsible for determination of and compliance with federal and state or local shipping requirements and other factors necessary to ship items at the desired locations. Place of Delivery The products will be delivered at the following sites: VA NYHHS Manhattan Campus Surgical Service Attn: Stanley Read 423 East 23nd Street New York, NY 10010 Security This equipment does not store patient information or connect to the VA computer system. Acceptance Procedures Prior to acceptance of the goods or services provided under this contract, inspection and testing will be performed by the Government in accordance with this clause. (a) Upon delivery the toners shall be turned over to the hospital for use. The contractor shall furnish, upon completion of installation, a written notice of readiness for inspection for the Contracting Officer or the COR when applicable. Recalls The Vendor shall immediately notify all affected VA Medical Centers and designated POC in the event of a instrument recall, removal, required adjustment, or required modification that is suggested or mandated by the Vendor, distributor, manufacturer, or any regulatory or government agency. The following information shall be included in this notification: A complete item description and identification (to include lot and serial numbers where applicable); Administrative identification data including order numbers and order date; Reasons for recall, removal, adjustment, or modification; and Instructions for appropriate corrective action.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/010a526f4c204f6ab68aeefc3cc7f078/view)
 
Place of Performance
Address: Department of Veterans Affairs New York Harbor Healthcare System Manhattan Campus 423 E 23rd St, New York 10010
Zip Code: 10010
 
Record
SN06899743-F 20231202/231130230053 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.