Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 14, 2023 SAM #8052
SOLICITATION NOTICE

65 -- Equipment, Endoscope Re-Processor, NIHCS

Notice Date
12/12/2023 4:48:12 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25024Q0173
 
Response Due
12/22/2023 9:00:00 AM
 
Archive Date
01/06/2024
 
Point of Contact
Alice A Clark, Contract Specialist, Phone: (269) 223-5048
 
E-Mail Address
alice.clark@va.gov
(alice.clark@va.gov)
 
Awardee
null
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as a Request for Quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular #2023-02 (February 14, 2023). This solicitation is for a firm fixed price: Open market brand name or equal. The associated North American Industrial Classification System (NAICS) code for this procurement is 339112, with a small business size standard of 1,000. The FSC/PSC is 6515. The Northern Indiana Veteran Affairs Medical Center, 2121 Lake Ave., Fort Wayne, IN 46805-5100 is seeking to purchase two endoscope reprocessor machines, to include installation and a service agreement. This solicitation also includes the deinstallation of the two current Medivators Advantage Plus endoscope reprocessing machines and their proper disposal. All interested companies shall provide quotations for the following list of items: (Note: freight not to exceed $250 for the entire order. If needed, include any additional cost of freight with your pricing.) Item # Manufacturer/Description/Part/ QTY Price   Model Number   ADV1007 Advantage Plus, Single Use Rapicide PA, 110 Volt, Air Compressor 2   CGS10132 Service Agreement 2   INS1004 Installation Agreement 2   Deinstall Medivators Advantage Plus Endoscope Reprocessors 2   Disposal Medivators Advantage Plus Endoscope Reprocessors 2   Freight Cost is included in each quote     Statement of Work The VA facility is requesting two FDA approved endoscope reprocessors that are high-quality, high-level disinfection systems that are fully automated, and computer based. Each endoscope reprocessor machine must be able to run two scopes independently of each other in two separate compartments, with two separate sets of data for each scope s cycle. Resultant contract must include installation and training of VA staff, immediately following installation. Contractor is required to decommission and remove the current two devices ( old devices ) prior to installation of the two new devices. Contractor is required to decontaminate old devices and dispose of old devices in accordance with all Federal, state, and local environmental laws. The endoscope reprocessors should have an average reprocessing time of approximately 35 minutes which is inclusive of leak testing, washing, disinfecting, rinsing and final alcohol and air purge. A. Water Supply and Drain Requirements Installation must not require any additional plumbing, any additional mechanical hook ups, any additional electrical work, or renovations of VA property. Contractor must have capability to utilize existing property, plumbing, hookups and electrical for the new devices. (please reference photo below) Machines should be able to accommodate a water supply between 90 to 50 degrees Fahrenheit Machines should be able to accommodate a water pressure no less than 30 PSI and no more than 90 PSI Machines should be able to have a water flow rate no higher than 1.5 gallons per minute (GPM) for both hot and cold water Machines should be able to accommodate a mixing valve 3 feet from the device Machines should have a pre-filter system to allow pure water to reach the instruments being disinfected in the device Machines should be able to accommodate a water hardness between 100-150 ppm Machines should have a vented drain system capable of draining no more than 4 GPM Machines should have a drain line that can reach up to 3 feet long B. Ventilation Machines should be able to be used in a room with at least 10 air exchanges per hour C. Electrical Requirements Machines should be able to withstand power consumptions of less than 1500 watts. Machines should be able to withstand heat loads of less than 2500 BTU per hour Machines should operate uninterrupted with power losses up to 0.5 seconds and have system alarms D. Unit Dimensions Weigh around 500 pounds per unit Height of less than 80 inches per unit Width of less than 70 inches per unit Depth of no more than 50 inches per unit E. Information Technology The endoscope reprocessor must have a windows based software program that continuously monitors all parameters, system sensors and verification testing including but not limited to: control of machine draining, control of the pre-rinse and final rinse requirements and execution of the proper self-disinfection cycle, compromised endoscope sheath (leak detection), disconnected or improperly connected channels, channel blockage, reservoir temperatures, open chamber, deviation from maximum/minimum cycle step times, electrical power supply at incorrect cycle phase, disinfection contact times, inadequate and unsatisfactory completion of self-disinfection phase. Results must be recorded in the data management storage system for patient safety and quality assurance reporting. Be equipped with a PC-based computer running Windows 10 Include a computer with at least 1 processor such as Intel i3-4330 CPU @ 3.5 GHz Should have a local storage capacity greater than 100 GB Should be able to be used without an internet connection. Should be a device that utilizes wireless communication Should have a storage capacity that lasts longer than 7 years Be able to store information such as users and endoscopes Be able to have security patches installed on the computer, if necessary Include anti-virus software and be HIPPA compliant To allow for remote diagnostics from an internet connection, if required F. Training G. Warranty Delivery: Delivery shall be provided FOB Destination within 90 days after receipt of order (ARO). The full text of FAR provisions or clauses may be accessed electronically at http://acquisition.gov/comp/far/index.html. The following solicitation provisions apply to this acquisition: FAR 52.212-1 Instructions to Offerors Commercial Items (SEPT 2023) FAR 52.212-3 Offerors Representations and Certifications Commercial Items (NOV 2023) Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://www.sam.gov/portal in accordance with FAR 52.212-3, Offerors Representations and Certifications Commercial Items. If paragraph (j) of the provision is applicable, a written submission is required. www.sam.gov registration is required to be complete at time of submission of quote. FAR 52.204-7 System for Award Management (OCT 2018) FAR 52.204-16 Commercial and Government Entity Code Reporting (AUG 2020) The following contract clauses apply to this acquisition: FAR 52.212-4, Contract Terms and Conditions Commercial Items (NOV 2023) Addendum to FAR 52.212-4 FAR 52.252-2 Clauses Incorporated by Reference (FEB 1998) http://www.acquisition.gov/far/index.html (FAR) and http://www.va.gov/oal/library/vaar/index.asp (VAAR) FAR 52.204-13 System for Award Management Maintenance (OCT 2018) FAR 52.204-18 Commercial and Government Entity Code Maintenance (AUG 2020) VAAR 852.211-70 Equipment Operation and Maintenance Manuals (NOV 2018) VAAR 852.212-71 Gray Market and Counterfeit Items (FEB 2023) VAAR 852.232-72 Electronic Submission of Payment Requests (NOV 2018) VAAR 852.242-71 Administrative Contracting Officer (OCT 2020) VAAR 852.246-71 Rejected Goods (OCT 2018) End of addendum to 52.212-4 FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Products and Commercial Services (NOV 2023) FAR 52.211-6 Brand Name of Equal (AUG 1999) VAAR 852.252-70 Solicitation Provisions or Clauses Incorporated by Reference (JAN 2008) VAAR 852.272-70 Late Offers (NOV 2021) All quotes shall be sent to the Contracting Specialist, Alice Clark at alice.clark@va.gov Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13. Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government. The award will be made to the response most advantageous and the BEST VALUE to the Government. Responses should contain your best terms, conditions. Quoters shall list exception(s) and rationale for the exception(s), if any. Submission of your response shall be received not later than 12:00 PM EST ON DECEMBER 22, 2023. Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail by 12 PM EST on December 19, 2023, to the Point of Contact for this solicitation; Alice Clark, Contracting Specialist, NCO10 Contracting, alice.clark@va.gov. No phone called will be accepted during this solicitation.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/f21a198d6e654059af1583917352d4c8/view)
 
Place of Performance
Address: Veteran Affairs, Northern Indiana ATTN: SPS 2121 Lake Avenue, Fort Wayne, IN 46805-5100, USA
Zip Code: 46805-5100
Country: USA
 
Record
SN06910264-F 20231214/231212230047 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.