Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 15, 2023 SAM #8053
SOURCES SOUGHT

Y -- USACE SPK Design Build Construction � T-7A Egress Facility � Hill AFB, UT

Notice Date
12/13/2023 3:13:22 PM
 
Notice Type
Sources Sought
 
NAICS
236210 — Industrial Building Construction
 
Contracting Office
W075 ENDIST SACRAMENTO SACRAMENTO CA 95814-2922 USA
 
ZIP Code
95814-2922
 
Solicitation Number
W9123824S0008
 
Response Due
1/12/2024 9:00:00 AM
 
Archive Date
01/27/2024
 
Point of Contact
Heidi May, Amelia Bryant
 
E-Mail Address
heidi.may@usace.army.mil, amelia.k.bryant@usace.army.mil
(heidi.may@usace.army.mil, amelia.k.bryant@usace.army.mil)
 
Description
This Sources Sought Notice is being issued for market research purposes to determine the availability, capability, and interest of small business firms for a potential Government requirement. NO SOLICITATION IS AVAILABLE; requests for a solicitation will go unanswered. No award will be made from this Notice. Responses will be used to determine potential acquisition strategies, understand current market capabilities, and to gain knowledge of potential sources. � GENERAL SCOPE: Design and construct a one-story egress facility (approximately 12,000SF) for depot-level repairs for the new T-7 advanced pilot trainer campus. Major functional components for the egress facility include canopy storage and repair for 16 canopies, seat storage and repair for 32 seats, staging and storage, common area, and office space. The project will include utilities, pavements, parking (approximately 3,804SY), site preparation, site improvements and all necessary supporting facilities for a complete and usable facility. Additionally, the facility will be designed as permanent construction in accordance with the Department of Defense Unified Facilities Criteria 1-200-01, General Building requirements. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facility Criteria 4-010-01. This design shall conform to criteria established in the Air Force Corporate Facilities Standards, the Installation Facilities Standards, but will not employ a standard facility design because there is no Air Force standard facility design for this project, and there is no applicable standard design from United States Army Corps of Engineers. Sustainable principles, to include life-cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with Unified Facility Criteria 1-200-02, High Performance and Sustainable Building Requirements. This includes preparation of a life-cycle cost analysis for energy consuming systems, renewable energy generating systems, whenever life-cycle cost effective is selected as the reason any requirement of Unified Facility Criteria 1-200-02 is partially compliant or not applicable. Facility is sited in accordance with the Installation Development Plan and is within a compatible land use area. This project does not fall within or partly within the 100-year flood plain. The anticipated requirement may result in a solicitation being issued approximately May 2024. If solicited, the Government intends to award the contemplated requirement as a firm-fixed-price contract by approximately December 2024. In accordance with Defense Federal Acquisition Regulation Supplement (DFARS) 236.204(i), the Government currently estimates the magnitude of construction for this project to be between $10,000,000 and $25,000,000. The North American Industrial Classification System (NAICS) code for the potential requirement is anticipated to be 236210 � Industrial Building Construction. The small business size standard for this NAICS, as established by the United States Small Business Administration, is $45,000,000.00 annual revenue. �The Product Service Code for the potential requirement is anticipated to be Y1EB, Construction of Maintenance Buildings If there is a reasonable expectation that at least two (2) responsible small business concerns under this NAICS can provide the anticipated services at fair market prices, the Contracting Officer is required to set the acquisition aside for small business concerns. If competition is set-aside for small businesses, FAR 52.219-14, Limitations on Subcontracting, requires that general construction small business Contractors self-perform at least fifteen percent (15%) of the cost of the contract, not including the cost of materials. If no set aside is made, the requirement is competed with full and open competition, and the awarded Contractor is not a small business, the Contractor is required to perform the percent of work identified in the solicitation under FAR 52.236-1, Performance of Work by the Contractor. Contractors with the skill, capabilities, workload capacity, and ability to obtain bonding to complete the project described above (either through self-performance and/or Subcontractor management) are invited to provide capability statements to the point of contact listed below. Other than small businesses are also encouraged to submit Capability Statements. � CAPABILITY STATEMENT: Responses must be limited to ten (10) 8.5 x 11 pages with a minimum font size of point 10. Please provide the following information: Company name, System for Award Management Unique Entity Identification number (SAM UEID) or Employer Identification Number�(EIN), address, point of contact, phone number, and e-mail address. Experience and capability to complete contracts of similar magnitude and complexity to the potential requirement, including at least three (3) examples of comparable work performed within the past six (6) years. Each example should include a brief description of the project, description of the work performed (identification of self-performance and/or Subcontractor management), customer name, customer satisfaction, timeliness of performance, dollar value of the project and whether there were any challenges experienced during the project (delays, investigations, health and safety issues, labor shortages, management/organizational issues, etc.). Business size and socioeconomic type for the applicable NAICS (ex: Woman-Owned Small Business, Serviced-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), certified Historically Underutilized Business Zone (HUBZone), 8(a) Participant, small business, or other than small business (large business)). Bonding capability (in the form of a Surety letter). Please submit all capabilities statements, information, brochures, and/or marketing material as one (1) document, limited to the page maximum above. Responses will not be considered an offer, proposal, or bid for any solicitation that may result from this Notice. Moreover, responses will not restrict the Government to an ultimate acquisition approach. This Notice is for information and planning purposes only. Respondents will not be notified of the results of any review conducted or the capability statements received. Please provide responses and/or questions by e-mail to the Contract Specialist, Heidi May, at heidi.may@usace.army.mil by 0900 / 9:00 AM (PST) Thursday, 12 Jan 2024. Please include the Sources Sought Notice number, �W9123824S0008� in the subject line.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/d2c5e379bf7c4cf1980f651feb8f3dfe/view)
 
Place of Performance
Address: Hill AFB, UT 84056, USA
Zip Code: 84056
Country: USA
 
Record
SN06911760-F 20231215/231213230046 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.