Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 21, 2023 SAM #8059
SOURCES SOUGHT

65 -- Generator FT10

Notice Date
12/19/2023 1:11:37 PM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
 
ZIP Code
98662
 
Solicitation Number
36C26024Q0177
 
Response Due
12/29/2023 3:00:00 PM
 
Archive Date
02/27/2024
 
Point of Contact
Tracy Heath, Contract Specialist, Phone: 253-888-4903
 
E-Mail Address
tracy.heath@va.gov
(tracy.heath@va.gov)
 
Awardee
null
 
Description
SOURCES SOUGHT NOTICE This is a Sources Sought NOTICE (SSN) ONLY. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement, and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), other Small Businesses interested and capable of providing items requested, as well as any large business interested and capable. This REQUEST FOR INFORMATION/SOURCES SOUGHT NOTICE in support of the Mann-Grandstaff VA Medical Center, Spokane, WA is for market research purposes only to determine the availability of potential vendors with capabilities to provide the requirement described below. This Request for Information/Sources Sought Notice is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation. Results will be used to determine set-aside. The intended contract is a firm-fixed price supply purchase. Potential contractors shall provide, at a minimum, the following information: 1) Company name, address, and point of contact, phone number, e-mail address, and SAM.gov UEI number/code. 2) Anticipated North American Industry Classification System (NAICS) code is 339112 (Surgical & Medical Instrument Manufacturing). The largest a firm can be and still qualify as a small business for Federal Government programs is no more than 1,000 Employees. Please indicate whether you are a Small Business, SDVOSB, VOSB, Small Business Manufacturer, Other Small Business, or Large Business, and whether you are the manufacturer of the item listed below. 3) The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this sources sought notice. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application in the System for Award Management (SAM). 4) Any Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetCert Registry located at Veteran Small Business Certification (sba.gov). 5) If not a manufacturer, only authorized representatives/providers/distributors of the manufacturer will be considered. Equipment must be new, no used or refurbished equipment accepted. Please provide a proof of authorized dealer or reseller letter from manufacturer. 6) If you are the manufacturer, do you have any designated or authorized distributors? If so, please provide their name, telephone, point of contact and size status (if available). 7) This is a brand name only requirement. Please identify manufacturer name (OEM) and manufacturer part number, as well as any warranty information. Please provide a courtesy quote in response to this request to evaluate price reasonableness for any set-aside determination. Please provide the country of origin. It is the intent of the VA to use the information gathered for market research purposes only. If a formal solicitation is released, it will be posted via the Contracting Opportunities website located at www.sam.gov or GSA eBuy. DESCRIPTION OF THE REQUIREMENT: The Department of Veterans Affairs is looking to obtain information on vendors who can provide the products as outlined below. This is an Unrestricted/Open Market Brand Name Only Request for Information/Sources Sought Notice. Delivery address: Mann-Grandstaff VA Medical Center Warehouse Bldg. 14 4815 N. Assembly St. Spokane, WA 99205 Items: Electrosurgical Energy Platform: 1 VLFT10GEN Generator FT10 Electrosurgical Energy Platform Cart: 1 VLFTCRT Cart FT10 Electrosurgical Energy Platform Footswitch s: 1 E6008 Standard Footswitch 1 E6019 DOM BIP Footswithc for Force Gen X1 Standard Warranty shall apply to all parts listed. Salient Characteristics: ValleyLab FT10 Generator Physical Specifications should be Name Brand: Height: 6.7"" (17 cm) Width: 14.1"" (35.8 cm) Depth: 18.2"" (46.25 cm) Weight: 22.3 lbs. (10,1 kg) Performance equal to: sealing times: (1-4 seconds vs. 3-6 seconds with ForceTriad ) Lower max jaw temperature Automatic power settings require minimal setup and minimize the need for further handling during surgery. Simple, intuitive controls and information displays. ES Settings: Soft coag TissueFect Tissue Sensing: Reads Tissue: 434,000 times per second. Bipolar Cable Compensation: Low Power Setting Ranges: Off, 1 15 W Peak Voltage: 133 V Medium Power Setting Ranges:16 40 W Peak Voltage: 214 V High Power Setting Ranges: 45 95 W Peak Voltage: 462 V Software: Ethernet Connection (Has WIFI Capabilities) General: Output configuration: Isolated output Cooling: Natural convection and fan Display: 7 in. LCD touchscreen Connector Receptacles: LED illuminated connector readers on the LigaSure/Bipolar receptacle Enclosure: Magnesium Operating System: Linx Environmental Parameters: Operating Temperature: 50 to 104 °F (10 to 40 °C) Operating Humidity: 30% to 75% non-condensing Operating Atmospheric Pressure: 700 to 1060 millibars Transport and Storage Temperature: 14 to 140 °F (-10 to +60 °C) Transport and Storage Humidity: 25% to 85% non-condensing Transport and Storage Atmospheric Pressure: 500 to 1060 millibars Internal Memory: Storage Capacity: 8 GB Input Power: 100-127 VAC Line Voltage Full Regulation Range: 90 140 VAC Line Frequency: 47-63 Hz Max VA Nominal Line Voltage: 950 VA Max Mains Current: 9.5 ARMS Max Heat Dissipation: 180 W 220-240 VAC Line Voltage Full Regulation Range: 198-264 VAC Line Frequency: 47 63 Hz Max VA Nominal Line Voltage: 950 VA Max Mains Current: 4.8 ARMS Max Heat Dissipation: 180 W Leakage: Touch Current: 1kHz): Scaled with frequency per IEC 60601-1:2012, but does not exceed 10mA NC/SFC Patient Leakage Current: < 10 A NC, < 50 A SFC Total Patient Leakage Current: < 50 A NC, < 100 A SFC ValleyLab FT10 Cart Name Brand: The Universal Generator Cart for Valleylab FT10 Energy Platform is designed to provide an excellent placement for storage and transportation of your FT10 generator. This cart is intended to give the user a convenient device mobility and an organized workspace, with its flat, and stable upper surface, perfect to place your electrosurgery device, and sturdy lower trays that can be used to store all the parts and accessories needed for the treatment.  This generator cart is assembled with 4 heavy duty casters, 2 locking and 2 non-locking, and a handle to ensure ease in maneuvering. It has a cord management system, and it's made with rust resistant material. Dimensions: 39.5 W x 52.75 H x 47.7 D Weight: 100 lbs. Covidien Standard Footswitch 15-foot water resistant Monopolar Footswitch Brand Name: Monopolar Footswitch is a standard monopolar footswitch for full-powered electrosurgical generators. Highlights: Compatible with ValleyLab FT10 Eletrosurgical energy platform. Water resistant built & strain relief connector. High quality cast aluminum 15 cord for added flexibility Divider bar between pedals Non-slip rubber base Covidien Bipolar Dome Footswitch 15-foot cord Brand name: This Step and go footswitch allow independent control of bipolar output during electrosurgery. Can be used in tandem with ValleyLab FT10 generators and can be activated from any angle. Bipolar Dome Footswitch must control bipolar output independently. Compatible with ValleyLab FT10 Electrosurgical energy platform. 15 cord for added range Activate from any angle. Control bipolar output. Foot-activated If your business is interested and capable, please send the capability statement outlined above, and a courtesy market research quote to Tracy.Heath@va.gov by 3:00pm PST on December 29, 2023. NO PHONE CALLS, PLEASE. Again, this is not a request for quote, and no solicitation is available at this time.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/3845d89fffb44c95ae12ce77aab0b3f1/view)
 
Place of Performance
Address: Mann-Grandstaff VA Medical Center Warehouse Bldg 14 4815 N. Assembly St., Spokane 99205, USA
Zip Code: 99205
Country: USA
 
Record
SN06917671-F 20231221/231219230056 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.