41 -- Equipment, Mobile Chiller, Battle Creek

Notice Date
1/3/2024 7:26:05 AM
 
Notice Type
Solicitation
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25024Q0195
 
Response Due
1/5/2024 11:00:00 AM
 
Archive Date
02/04/2024
 
Point of Contact
Noah R Bruck, Contract Specialist
 
E-Mail Address
Noah.Bruck@va.gov
(Noah.Bruck@va.gov)
 
Awardee
null
 
Description
1. Description. Purchase 80 Ton Chiller and trailer. 2. Background. Battle Creek VAMC requires the purchase of Purchase of a new 80 Ton CGAM air cooled chiller with pumping package that will be mounted on a new furnished trailer. The Chiller will be used as a backup chiller source for HVAC systems for various buildings as needed during service issues. 3. Scope. Purchase new Trane 80 Ton CGAM air cooled chiller with pumping package (Brand Name or Equal) mounted on a mobile trailer. Vendor will mount the chiller on the new tailer. 4. Specific Tasks. Purchase new Trane 80 Ton CGAM air cooled chiller with pumping package mounted on a trailer. Offers shall supply authorized distributor letters from the manufacturer along with their submission to be considered for award. The following minimum requirements must be met: (1) 80-ton CGAM air cooled chiller, including: Air-Cooled Scroll Packaged Chiller 80 nominal tons 60 hertz 460 volt 3 phases High efficiency/performance Full factory refrigerant charge (R-454B) With factory installed freeze protection Refrigerant isolation valves (discharge valve) UL listed to US and Canadian safety standard ASHRAE 90.1 all versions up to 2016 AHRI certified Factory installed flow switch - set point 60 cm/sec Std cooling (40 to 65F/4.44 to 18C) Grooved pipe connection Factory insulation 0.75"" Wide ambient (0 to 125F/-18 to 52C) Lanced aluminum fins Across the line starter/direct on line Single point connection main line unit power-ancillary items require other power Circuit breaker Enclosure type UL 1995 rated for outdoor applications BACnet interface External chilled/hot water and demand limit setpoint - 4-20mA Default A short circuit rating Elastomeric isolators With water strainer factory installed Comprehensive acoustic package Architectural louvered panels (2) Integral pumping and piping package including: Integral Piping Package with: -Pump: Taco 275 GPM at 150 ft H2O, 20 HP, Water, TEFC, Shaft Grounding Ring, Drip Cap -Suction Diffuser -¾ Thread-O-Let on Pump Suction Line with Cap -1 TR200 VFD 20 HP with 3-Contactor Bypass in NEMA 3R Enclosure --Non-Fused Disconnect Switch --Pump Line-Off-Auto Switch --Hand-Off-Auto Switch with Status Indicator Light --Door mount VFD Display with Weather Cover -Lever Operated Grooved Isolation and pump bypass Butterfly Valves -4 Schedule 40 Grooved/Welded Steel Pipe, Valves, and Fittings -Connection Pressure and Temperature Gauges -150 PSI Pressure Relief Valve with Manual Test -Differential Pressure Gauge Manifolds with 0-160psi Gauge: --Suction Guide Inlet, Pump Suction, Pump Discharge --Evaporator Strainer Inlet, Evaporator Inlet/Strainer Outlet, Evaporator Outlet -Supply and Return Connections: -4 Victaulic -Gear Operated Butterfly Valves -Temperature and Pressure Gauges -Insulation on hydronic piping Cam Lock Main Power Connections with Covers 120/60/1 20A Shore Power Connection (controls, & compressor heaters) -Electrical interlock on HV control panel door -Back-feed Prevention -RC Snubber 460x120V 3kVA Transformer to Power Convenience outlet and Evaporator heaters -Evaporator Heaters Off-Auto Switch with Indicator Light Extended Vent and Drain Lines to side of unit Miscellaneous Components -200 Flex Hose -2 50 ft & 4 25 ft Sections with grooved ends -6 4 grooved couplings -Qty 16 (4 per phase plus ground) - 50 M->F Cam lock 2/0 AWG Power Cables -2 Storage Boxes for Power Cables and Hoses -Chiller mounted (bolted) to owner furnished trailer (delivered to Vendor to have chiller installed) 1-year parts warranty (1-year parts warranty is not covered by 12/36 delayed startup protection) Freight to customer site Unit tested prior to shipment. Provide new mobile trailer at correct size and weight to support the chiller. Chiller to be mounted on the trailer for delivery to the VA.     5. Delivery Schedule. Offerors shall provide estimated delivery lead times upon submission.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/4541f0cc7b5044aea28a9d804b12dc19/view)
 
Record
SN06925849-F 20240105/240103230044 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.