65 -- WATER PURFICATION SYSTEM HCC1 LAB
- Notice Date
- 2/7/2024 12:02:28 PM
- Notice Type
- Sources Sought
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- 246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
- ZIP Code
- 23667
- Solicitation Number
- 36C24624Q0414
- Response Due
- 2/13/2024 7:00:00 AM
- Archive Date
- 02/23/2024
- Point of Contact
- John P Harmsen, Contract Specialist, Phone: 757-722-7961
- E-Mail Address
-
john.harmsen@va.gov
(john.harmsen@va.gov)
- Awardee
- null
- Description
- VA Chesapeake Community Based Outpatient Clinic (CBOC) Chesapeake HCC1 Salient Characteristics Water Purification System that is capable of producing not less than 200 liters of water per hour, fitted with deionization capabilities MODEL MEDICA-R 200 Make-up rate @15°C 200 l/hr Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1) Organics (TOC) - typical 250 Softener or use very low RO recovery3 Free chlorine: Cl2ppm 0.5 Cylinder of carbon sized correctly to obtain 0.5 Cylinder of carbon sized correctly to obtain 30 20 inch cartridge depth filter or use very low RO recovery (4) Fouling index: FI 20 Back washable media filter with a minimum flow rate of 20 l/min Iron/manganese: Fe/Mn ppm 0.05 20 inch cartridge depth filter (5) >0.1 Back-washable Fe filter (6) Organics: TOC ppm C 3 Cylinder of carbon sized correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C) - Flowrate: (requirement at 15°C) 20 l/min Drain requirements: (gravity fall with air gap) 45 l/min Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning, 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required) Must include: Installation, Commissioning, Training Electrical Requirements Mains Input: 115V, 60Hz System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA Electrical protection rating 20 amps Noise level during recirculation <70dBA ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters. -The floor drain must be a minimum of 3"" and meet all applicable building codes and system requirements -Actual Unit measurement 32"" Wide x35""Deep x72""High VA Chesapeake Community Based Outpatient Clinic (CBOC) Chesapeake HCC1 Page 10 of 10 - - - - Qty: 1 - Finishes/Options - Image PATHOLOGY AND LABORATORY LAB-C1012(1) Department, Room, Quantity
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/50d80859ab0f459cb3a84498dcc2de5b/view)
- Place of Performance
- Address: VAMC Hampton 100 Emancipation Dr, Hampton 23667
- Zip Code: 23667
- Zip Code: 23667
- Record
- SN06958817-F 20240209/240207230052 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |