Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 15, 2024 SAM #8115
SOURCES SOUGHT

65 -- Cart Washer

Notice Date
2/13/2024 10:01:46 AM
 
Notice Type
Sources Sought
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
262-NETWORK CONTRACT OFFICE 22 (36C262) Gilbert AZ 85297 USA
 
ZIP Code
85297
 
Solicitation Number
36C26224Q0580
 
Response Due
2/21/2024 10:00:00 AM
 
Archive Date
03/22/2024
 
Point of Contact
Hestia Sim, Contract Specialist
 
E-Mail Address
Hestia.Sim@va.gov
(Hestia.Sim@va.gov)
 
Awardee
null
 
Description
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Responses to this sources sought notice must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential businesses interested and capable of providing the supplies described below. VA Greater Los Angeles Healthcare System Sterile Processing Service (SPS) located in 11301 Wilshire Boulevard, Los Angeles, CA 90073 is looking for a contractor to provide cart washer. Cart Washer is to help with high-capacity reprocessing needs in an energy-efficient design from utensils to surgical tables. The system is to deliver the reliable cleaning needed to prevent cross-contamination and keep patient safes at VA. Refer to below Statement of Work for detailed requirements. STATEMENT OF WORK This project is part of the Department of Veterans Affairs Greater Los Angeles Veterans Health Care System Located at: 11301 Wilshire Blvd., Los Angeles, CA 90073 INTRODUCTION This shall be a firm fixed-price contract to order Cart Washers equipment including installation service in order to safely to clean and disinfect transport carts, containers, bowls, basins, and bulky items in the Sterile Processing Service. SCOPE OF WORK: This statement of work (SOW) describes the requirement for the need of the Cart Washers system for the GLA Healthcare System. The SOW will include delivery, installation, and training for this new equipment. PRODUCT DESCRIPTION VAMC West Los Angeles Sterile Processing Service uses chemical sterilizers and high-level disinfection equipment in Sterile Processing to sterilize instruments that come into contact with patients. solutions to deliver the highest levels of cleaning and efficiency. The cart washer can safely clean and disinfect transport carts, containers, bowls, basins, and other bulky items, and with a dedicated instrument program cycle and instrument wash cart, the 9125E can back up instrument washers during peak hours or unexpected washer downtime. With Getinge 9100E, you can choose from multiple modes of operation: standard water and detergent use, or efficiency mode. Efficiency mode reduces the consumption of water, detergents, and energy for cost-effective operation. The increased throughput and reduced operating costs ensure that you maximize the return on your investment. The Getinge 9100E Cart Washer provides: Effective cleaning coverage with 128 spray nozzles; Improved air barrier that reduces demands on building ventilation with an improved air barrier that helps maintain differential pressure between zones; Re-Use technology reducing utilities, water, and detergent consumption with 9100E re-use technology; Getinge 9100 Centric intuitive interface providing safe and easy operation with smart and intuitive Centric user interface. Salient Characteristics of Cart Washer: The cart washer must be plug and play and fit WxDxH = 960 x 2500 x 2000 mm (37.8 x 98.4 x 78.7 ). The cart washer must have Laminated Safety Glass Doors Four laminated layers of safety tempered glass must provide a full-size viewing door to the loading and unloading side of the chamber. Laminated glass provides excellent sound and heat abatement, as well as an extra measure of operator safety. Power operated door glides effortlessly across the chamber opening to store completely behind the barrier wall panel. The cart washer must have Compressed Gasket Seal Power operated doors must separate from the door gasket during opening and closing. Air cylinders automatically compress the glass door against the chamber gasket, providing a positive seal to air and water leakage. When door is opened, the air cylinders release the glass door pressure against the door gasket, separating the seal before the door slides open. The cart washer must have a Double Door Pass Through Doors at each end of the chamber must promote a convenient and aseptic flow of goods from a soiled work area to a clean prep & pack area. Door interlocks assure integrity of barrier wall by allowing only one door to be open at any given time. The cart washer must have Automatic Cart Transition Plate An automated door sill or cart transition plate remains separated from the chamber floor when the door is moving. When the door is opened and completely stored, the transition plate must automatically slides across the door track to provide a smooth transition for wheeled loading carts and racks. The cart washer must have a Level Chamber Floor Chamber must be fitted with removable sections of floor grates that provide drainage to the sump as well as a level walking and rolling surface to facilitate loading and unloading of materials. The cart washer must have Gross Debris Filters Two sets of gross debris filter screens are located beneath floor panels to filter water entering the sump and are easily removed for cleaning. The cart washer must have Chamber Guardrails Removable rails must be fitted over the length of the chamber to prevent loads from contacting the reciprocating spray manifolds. Rail mounting positions must be adjustable in height to accommodate various loads. Additional adjustable, floor mounted rails are provided to guide process cartwheels into the chamber and restrict rolling of loads during floor tilt. The cart washer must have Top Mounted Filling Valves. Two air-operated valves are mounted on top of the chamber for connection to building hot and cold-water supply. Filling through top of chamber eliminates dead legs and provides the air-break to protect potable water from cross-contamination. The cart washer must have Shallow Sump Low profile of the sump = holds 32 gallons (120 liters) of water. 6-inch (150 mm) high base frame can be floor mounted with ramps or recessed in a shallow 6-inch-deep pit. The cart washer must provide High-Volume/Low-Pressure Wash Solution from the sump is pressurized by a 5.1 HP (3.8 kW) pump with a flow rate of 105 gallons/minute (400 liters/minute) to minimize shifting of the load and potential damage. The cart washer must have Booster Heater Solutions from the wash pump are forced through a powerful steam to water heat exchanger to rapidly elevate process water temperature at a rate of 12°-18°F/ minute (7°-10°C/minute). Wash and rinse temperatures must be adjustable from 120°-194°F (49°-90°C). The cart washer must have a Self-Cleaning Debris Filter Solutions from the booster heater are forced through a canister containing a removable fine mesh filter, to prevent debris from reaching spray nozzles. Upon completion of the wash cycle, the flow through the filter is reversed and debris is back-flushed into the drain to minimize manual cleaning. The cart washer must have Oscillating Jet-Spray Manifold Oscillating, lateral sweeping, vertical jet-spray manifolds with 128 spray jets evenly distributed throughout the chamber provide full load coverage during the entire cycle for optimum cleaning. Both tubes and jets must be easily removable without tools for easy maintenance. The cart washer must have Automatic Chemical Dispensing Two peristaltic chemical dosing pumps are provided standard with flow meters for volume-based injection of chemicals in the wash and rinse phases to ensure accurate dosing. Pumps must be self-priming and dosing levels are controlled by cycle parameters. The cart washer must have a Drain Pump A 0.4 HP (30W) drain pump with a capacity of 37 gallons/minute (140 liters/minute) pumps wash and rinse solutions to an effluent tank for handling prior to gravity draining into the building waste system. The cart washer must have Drain Tempering. The cart washer Brushless Fan Motor. The cart washer must have Steam Coil Drying Heater. The cart washer must have Forced Air Drying. The cart washer must have Non-Recirculated Drying Air. The cart washer must have Energy Efficient Heat Exchanger. The cart washer must have Building Exhaust Connection. The chamber vent tube must be 6.25-inch (160 mm) diameter and is designed to require building exhaust to evacuate a blend of ambient air in the machine space with exhaust from the machine vent tube. Provide a 2-inch air gap between the building exhaust vent and the machine vent tube. The total building exhaust shall be 700-1200 CFM. This action helps dry the moist air moving into the building exhaust and helps reduce the temperature in the machine space. The cart washer must have a Smooth surfaces and slope angle allow the pipe system and chamber to completely drain, eliminating the risk for residuals and dirt to be carried over to the next process. QUANTITIES LINE ITEM DESCRIPTION Part# QTY 0001 Getinge WASHER DISINFECTOR 9125E 9125E-001 1 EA 0002 INCLINED DOOR, PASSTROUGH: 9100E XZWA000722 1 EA 0003 PERFORMANCE DRYER XZWA000727 1 EA 0004 STEAM HEATED OTHER THAN 400V: 9100E XZWA000728 1 EA 0005 DEONIZED WATER DiW VALVE: 9100E XZWA000730 1 EA 0006 WATER DOCKING FOR WASH CARTS: 9100E XZWA000732 1 EA 0007 BOOSTER TANK XZWA000733 1 EA 0008 1 REUSE TANK 150L XZWA000735 1 EA 0009 DETERGENT PUMP 3,4 XZWA000740 1 EA 0010 FLOWMETER PUMP 1, 2, 3, 4: 9100E XZWA000743 1 EA 0011 DRAIN COOLING XZWA000750 1 EA 0012 USB STORAGE XZWA000755 1 EA 0013 A/C IN ELECTRICAL ENCLOSURE: 9100E XZWA000758 1 EA 0014 INST. KIT CW+HW+DiW, ST HEAT: 9100E XZWA000763 1 EA 0015 SEISMIC ANCHORAGE XZWA000764 1 EA 0016 TRIM PANEL PIT MOUNTED 6001823801 2 EA 0017 Audible and visual alarm add-on kit for 9100/9027- series washer-disinfectors to indicate cycle completion. MP224 1 EA 0018 Seismic Anchoring Level 3 (88T AGS) ZSUS6630-S-ANCHOR3 1 EA 0019 MP197 CONDENSATE COOLING TANK FOR 9100 WASHER-DISINFECTORS D020021 1 EA 0020 Getinge Online Subscription Connecting Getinge Online to the Infection Control devices in your facility brings life cycle and preventative maintenance data together for ease of equipment management, service diagnosis and more rapid repair through an easy to read web-based format. Getinge Online, valued at $495 per unit, is included: (a) for the first year of the manufacturer s warranty period for any new equipment purchases (""""Warranty Period""""), and (b) in the first year of any Getinge Service Plan for existing equipment (""""Service Plan""""). At the end of the first year of either a Warranty Period or a Service Plan, should the customer wish to continue to use Getinge Online, they may purchase a subscription to Getinge Online for an additional annual charge of $495. Should the customer choose not to subscribe to Getinge Online, Getinge reserves the right to maintain connectivity to the device for remote diagnostic purposes only ZSUSONLINEPREM10 1 EA 0021 Installation and Removal of 9100-E Series Cart Washer ZSUS15610-IR-9100E 1 EA 0022 UNIVERSAL MANIFOLD WASH CART: UNIVERSAL MANIFOLD WASH CART 2000 w/ spray arms, 3 shelves, 2000x1985 mm 6001706701 1 EA 0023 INSTRUMENT WASH CART *Can only be ordered with new orders together with washers 6002116701 1 EA PERIOD OF PERFORMANCE The anticipated period of performance will be for 16-20 weeks starting on the date of award. The period of performance will end after all units have been installed and training has been completed. Vendor will provide installation and in-service training for the new monitors as well as how to change out the sensors. Vendor will ensure everything is installed and working properly while on site. DELIVERY Delivery will be coordinated with GLA Warehouse Bldg. 297 on the delivery date and time with the selected vendor. Vendor shall deliver materials to job in manufacturer's original sealed containers with brand name marked thereon. Vendor shall package to prevent damage or deterioration during shipment, handling, and storage. All delayed delivery arrangements, within 60 days, shall be at no additional cost to the Government. Locations: Building 500 Warehouse, Decon and Prep Room 0444C, Sterile Processing Service, VAMC West Los Angeles. INSTALLATION This equipment requires installation and will be delivered to each location and installed by the vendor. Installation must be performed by licensed and bonded installers. The SPS management will accompany the vendor to each location to ensure proper installation and to answer any questions. Upon the completion of each step in the installation process, the VA s corresponding trade professional shall inspect and give approval to continue. Installation should be completed after delivery to each location listed below: Building 500, Decon and Prep Room 0444C, Sterile Processing Service, VAMC West Los Angeles 11301 Wilshire Blvd, Los Angeles, CA 90073 TRAINING Vendor will provide installation and in-service training for the new cart washer as well as how to properly use the washer. Vendor will ensure everything is installed and working properly while on site. VENDOR FURNISHED ITEMS AND RESPONSIBILITIES The selected vendor shall furnish all items as described in the statement of work. Do not use VA dumpsters for disposal of scrap/waste without prior VA approval. The cabinets will need to be tagged and tracked in the BioMed/Logistics database upon delivery to each location and before prior to installation. The product must not be used without clearance from the SPS Management, or RMD Coordinators to ensure the product is properly installed. The contractor shall track manufacturing schedule and notify VA Contracting Officer and SPS Management with updates of estimated completion date by email. The Contractor shall provide a point of contact. INSPECTION AND ACCEPTANCE The Program Officer shall inspect the delivery and sign off all missing or damaged products in the form of a delivery manifest, vendor provided. The GLA Warehouse shall ensure all delivery of merchandise is completed and received satisfactorily prior to acceptance. Disputes shall be resolved by the Contracting Officer. INTERFERENCE TO NORMAL FUNCTION The selected vendor may be required to interrupt their work at any time so as not to interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of facility patients, personnel, equipment, and carts. In the event of an emergency, work performance may be stopped and rescheduled at no additional cost to the government. The selected vendor s personnel shall inform the Chief of Sterile Processing or the designee of the need to gain access to secured areas. If access is required to secure areas, prearranged scheduling will be made with the Chief of Sterile Processing or designee. Items being offered must be in compliance with the Buy American Act. If you are interested and are capable of providing the required supplies, please provide the following information. (1) Company Name, Address, Point of Contact (2) Size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (3) Is your company considered small under the NAICS code 339113 Surgical Appliance and Supplies Manufacturing (4) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract type and number. (5) If you are an FSS GSA/NAC or other federal contract holder, are the referenced items/solutions available on your schedule/contract? (6) Please provide general pricing and product lead time for your products/solutions for market research purposes. (7) Please submit a capability statement that addresses qualifications and verifies ability to perform work described above. The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought announcement. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service Disabled Veteran Owned Small Businesses. However, if there are insufficient Service Disabled Veteran Owned Small Business responses, an alternate set-aside or full and open competition may be determined. No sub-contracting opportunity is anticipated. The North American Classification System (NAICS) code for this acquisition is 339113 (800 employees). Responses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted. Responses must be received no later than 2/21/2024 10:00 AM Pacific Local Time. After review of the responses to this sources sought announcement, a solicitation may be published on the beta.sam.gov or GSA eBuy websites. Responses to this sources sought announcement will not be considered adequate responses to the solicitation. All interested offerors must respond to the solicitation in addition to responding to this sources sought announcement. Prospective bidders must be authorized re-sellers in order to participate in the solicitation process. Notice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov. Additionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses must be registered with U.S. Small Business Administration (SBA) located at http://veterans.certify.sba.gov.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/714f5422a67c4c2d99fbb5fc8c09bae5/view)
 
Place of Performance
Address: Department of Veterans Affairs VA Los Angeles Healthcare System Sterile Processing Service 11301 Wilshire Blvd, Los Angeles 90073, USA
Zip Code: 90073
Country: USA
 
Record
SN06965024-F 20240215/240213230047 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.