46 -- WATER PURFICATION SYSTEM HCC1 LAB

Notice Date
2/29/2024 6:50:46 AM
 
Notice Type
Presolicitation
 
NAICS
333310 —
 
Contracting Office
246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
 
ZIP Code
23667
 
Solicitation Number
36C24624Q0414
 
Response Due
3/6/2024 7:00:00 AM
 
Archive Date
03/11/2024
 
Point of Contact
John P Harmsen, Contract Specialist, Phone: 757-722-7961
 
E-Mail Address
john.harmsen@va.gov
(john.harmsen@va.gov)
 
Awardee
null
 
Description
VA Chesapeake Community Based Outpatient Clinic (CBOC) Chesapeake HCC1 Salient Characteristics Water Purification System that is capable of producing not less than 200 liters of water per hour, fitted with deionization capabilities MODEL MEDICA-R 200 Make-up rate @15°C 200 l/hr Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1) Organics (TOC) - typical 250 Softener or use very low RO recovery3 Free chlorine: Cl2ppm 0.5 Cylinder of carbon sized correctly to obtain 0.5 Cylinder of carbon sized correctly to obtain 30 20 inch cartridge depth filter or use very low RO recovery (4) Fouling index: FI 20 Back washable media filter with a minimum flow rate of 20 l/min Iron/manganese: Fe/Mn ppm 0.05 20 inch cartridge depth filter (5) >0.1 Back-washable Fe filter (6) Organics: TOC ppm C 3 Cylinder of carbon sized correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C) - Flowrate: (requirement at 15°C) 20 l/min Drain requirements: (gravity fall with air gap) 45 l/min Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning, 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required) Must include: Installation, Commissioning, Training Electrical Requirements Mains Input: 115V, 60Hz System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA Electrical protection rating 20 amps Noise level during recirculation <70dBA ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters. -The floor drain must be a minimum of 3"" and meet all applicable building codes and system requirements -Actual Unit measurement 32"" Wide x35""Deep x72""High VA Chesapeake Community Based Outpatient Clinic (CBOC) Chesapeake HCC1 Page 10 of 10 - - - - Qty: 1 - Finishes/Options - Image PATHOLOGY AND LABORATORY LAB-C1012(1) Department, Room, Quantity
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/01da7c306c6e4ab1b6ba3d64e13ecc93/view)
 
Record
SN06981776-F 20240302/240229230102 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.