Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 22, 2024 SAM #8212
SOLICITATION NOTICE

J -- FY24: GVL Boiler Remote Alarm Panel Install

Notice Date
5/20/2024 12:59:30 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24824Q0925
 
Response Due
5/31/2024 9:00:00 AM
 
Archive Date
07/30/2024
 
Point of Contact
Yolanda Glover, Contract Specialist, Phone: 352-381-5712
 
E-Mail Address
yolanda.glover@va.gov
(yolanda.glover@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
The Purpose of this Amendment is to: Extend the closing date to 05/31/2024 at 12:00 PM EST. Answer questions for RFQ# 36C24824Q0925. Question: Is this a brand new contract? Answer: Yes Question: Is there an incumbent performing these services? Answer: No Question: Provide the current / previous contract number? Answer: N/A Question: Is there an actual start date for the project? Answer: No Question: DA Steam Relief Valve Is this the relief valve directly on the DA tank(DASV), or the on the steam line feeding the DA tank, after the PRV (SRFPRV)? Answer: On the DA Tank Contractor stated-à( Per VHA safety device manual 8th edition, the DASV on the DA tank is required to have a capacity of approximately 1000 lb/hr., and setpoint pressure 5psig higher than normal DA Tank pressure, while the SRFPRV is required to have setpoint 5 psig higher than DASV, which may place it higher than the requested 15psig setpoint).  Question: In absence of project specific plans and specs, will the new remote alarm panel be required to meet Master TIL 23 09 11, pp2.3.J. Annunciator? Answer: Yes Question: Is the intent to have the remote panel be a stand-alone unit, or will it need to communicate alarm states back to plant master or SCADA workstation? Answer: Needs to communicate with the SCADA Question: Are there additional contacts on the existing, local DA & Surge tank alarms that can be used for the remote panel, or will additional devices be required to be installed? Answer: No Question: Does the existing MSA CP Monitoring system have the expansion capability to accept the two new CO sensors, or will it need to be updated with the additional channels?   Answer: Unknown.  System is out for repairs.  Cannot provide details on it. Question: What is the manufacturer s model number of the existing MSA CP Monitoring system? Answer: Unknown.  System is out for repairs.  Cannot provide details on it. Contractor stated--à(There are several controllers listed that are discontinued, so support for these older models may not be available.) Question: Is this CLIN for the wire required for the project, or is it for spares?  Answer: Wire required for the project Contractor stated--à(The CLIN line item 5 requests separate pricing for qty(1) roll of wire.  This does not specify the type of wire, number of conductors, length of spool, etc ) Question: Is this conduit for the installation portion of the project?  Answer: Exact measurements should be taken by contractor.  But Qty (10) is in 10 sections.  Therefore the total length is approx. 100 Contractor stated-à(The CLIN line item 4 requests separate pricing for Qty(10) conduit.  This line item does not specify length of each conduit, or size.) Question: Is the pricing for the wire and conduit to be removed from CLIN 2 & 3, and only include as parts the devices, hangers, fittings, and other misc. parts required for the installation? Answer: Pricing should include parts required for installation of conduit and wiring. Contractor stated-à(CLIN line items 2 & 3 requests pricing to include parts, labor and freight.  The conduit and wire pricing for CLIN line items 4 & 5, would be included in the Parts portion of CLIN 2 & 3.)
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/af8d7bb1627b444fa314f17ae38547d6/view)
 
Place of Performance
Address: Malcolm Randall VAMC 1601 SW Archer Road, Gainesville, FL 32608, USA
Zip Code: 32608
Country: USA
 
Record
SN07069942-F 20240522/240520230050 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.