Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 19, 2024 SAM #8240
SOLICITATION NOTICE

Z -- PA056 LANCASTER USARC HVAC

Notice Date
6/17/2024 1:49:21 PM
 
Notice Type
Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
W2SD ENDIST PHILADELPHIA PHILADELPHIA PA 19103-0000 USA
 
ZIP Code
19103-0000
 
Solicitation Number
W912BU-24-R-0032
 
Response Due
6/24/2024 2:00:00 PM
 
Archive Date
07/09/2024
 
Point of Contact
Henry Barron, Phone: 2156566855, Cherita Williams, Phone: 2156566775
 
E-Mail Address
Henry.D.Barron@usace.army.mil, cherita.l.williams@usace.army.mil
(Henry.D.Barron@usace.army.mil, cherita.l.williams@usace.army.mil)
 
Small Business Set-Aside
8A 8(a) Set-Aside (FAR 19.8)
 
Description
The Lancaster USARC is located at 1135 Ranck Mill RD, Lancaster, PA 17602 and consists of two buildings which are the USARC Training Building and the Organizational Maintenance Shop (OMS). Work under this contract shall occur at the Training Building. Design and construct a HVAC system, associated power distribution circuits, and suspended ceiling systems at the Training Building. Remove the portions indicated of the existing HVAC system, associated power distribution circuits, and the suspended ceiling system. Provide temporary heating and cooling when one, both, or the other are unavailable due to construction activities. Complete an energy model, based on the final design, to report energy reductions in accordance with the applicable criteria. Proposals that offer betterments that impact energy efficiency must be supported by a life-cycle cost analysis. Design and construction includes, but is not limited to, the following equipment: split Direct Expansion (DX) variable air volume air handling units; condensing units; piping; ductwork; insulation; Variable Air Volume (VAV) boxes; hydronic terminal units; Direct Digital Control (DDC) system; conduit; conductors; overcurrent protection; safety disconnect switches; acoustical ceiling tiles; and suspended ceiling grid system. See Parts 4, 5, and 6 for technical requirements. See Appendix D for as-built drawings and Appendix E for site photographs. These are provided for information only and shall be field verified after award. As-builts are available upon request after award in Adobe PDF format. Provide as-built drawings in accordance with Section 01 78 00. See Appendix C for demolition and new work drawings (which include a suggested zoning plan). Appendix F provides a control system design guide which shall be followed to complete the design. EDIT: 17 June 2024- AMENDMENTS 0002 AND 0003 TO THE SOLICATION WERE ADDED TO SAM.GOV.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/d084ffdefd784b22a1f32c49b3eaab29/view)
 
Place of Performance
Address: Lancaster, PA 17602, USA
Zip Code: 17602
Country: USA
 
Record
SN07099486-F 20240619/240617230117 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |