SOLICITATION NOTICE
59 -- 4 SOPS B300 mod 12 Conduit Install
- Notice Date
- 7/3/2024 12:43:19 PM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- FA2550 50 CONS PKP SCHRIEVER SFB CO 80912-2116 USA
- ZIP Code
- 80912-2116
- Solicitation Number
- FA255024Q0022
- Response Due
- 7/26/2024 12:00:00 PM
- Archive Date
- 08/10/2024
- Point of Contact
- Melanie A. Briggs, Phone: 7195673898, Alejandro Castellanos, Phone: 7195676185
- E-Mail Address
-
melanie.briggs.2@spaceforce.mil, alejandro.castellanos@spaceforce.mil
(melanie.briggs.2@spaceforce.mil, alejandro.castellanos@spaceforce.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- 4 SOPS needs to have 2in diameter conduit installed within MOD 12 South, building 400. �The contractor will install new plenum rated conduit in the MOD 12 South sub floor between the bldg. 400, second floor cable vault and the MOD 12 South server room (room 17). They will install new wall penetration (also referred to as a window) from the cable vault in the sub floor between MOD 12 South and the cable vault. This penetration can go along the MOD 12 South East perimeter wall. There is a potential to use an existing window within room 14. The contractor will install two new floor penetrations within the server room where the conduit exits the sub floor at racks 006 and 011. These penetrations should be big enough for the conduit (or flex tube) and additional server rack cabling outside the conduit. Approximately 4inx4in is needed for the cables outside the conduit. They will install plenum rated conduit for BLACK cables from racks 006 and 011 in the MOD 12 South server room to seat 52. The contractor will install plenum rated conduit for RED cables from racks 006 and 011 in the MOD 12 South server room to seat 52. They will install two new 3-inch floor penetrations at seat 52 for the BLACK and RED conduits. The contractor will install one new 3-inch floor penetration at seat 52 for cabling outside of the conduit (or flex tubing).�
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/ccc3264d9edb40b1a1629403329950f4/view)
- Place of Performance
- Address: Colorado Springs, CO 80912, USA
- Zip Code: 80912
- Country: USA
- Zip Code: 80912
- Record
- SN07117461-F 20240705/240703230115 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |