Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 17, 2024 SAM #8268
SOLICITATION NOTICE

66 -- GCxGC Mass Spectrometry System

Notice Date
7/15/2024 3:26:12 PM
 
Notice Type
Presolicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
NAVAL AIR WARFARE CENTER CHINA LAKE CA 93555-6018 USA
 
ZIP Code
93555-6018
 
Solicitation Number
N6893624Q0127
 
Response Due
7/29/2024 12:00:00 PM
 
Archive Date
07/29/2025
 
Point of Contact
Brandi Smith, Phone: 7606080281, Scott Hansen, Phone: 7607934451
 
E-Mail Address
brandi.c.smith6.civ@us.navy.mil, scott.c.hansen.civ@us.navy.mil
(brandi.c.smith6.civ@us.navy.mil, scott.c.hansen.civ@us.navy.mil)
 
Description
The Naval Air Warfare Center, Weapons Division, China Lake, CA, intends to issue an RFQ on an other than full and open basis to LECO Corporation, in accordance with FAR 6.302-1, only one responsible source and no other supplies or services will satisfy agency requirements. The acquisition is for one LECO GC-HRT+ 4D system (High Resolution Time of Flight with GCxGC Mass Spectrometry System). The system shall be comprised of the following: LECO GC-HRT+ 4D system (High Resolution Time of Flight with GCxGC Mass Spectrometry system) with current Agilent GC, Split/Splitless injector, Inert Flowpath, and liquid nitrogen (LN2) cooled GCxGC thermal modulator.� ��� �The GCxGC system must be fully integrated, providing control of the GC, thermal modulator, secondary column oven, detectors, GCxGC data processing software. ��� �The GCxGC system must be capable of detecting 100 fg of octafluoronaphthalene (OFN) injected and analyzed in EI GCxGC mode. ��� �The GCxGC system should have a second dimension retention time reproducibility of no greater than �10 milliseconds. ��� �The GCxGC system should have an isolated secondary oven that can be controlled and programmed directly through the main data system. The secondary oven must be independently programmable from the main GC oven to enable adjustment of second dimension retention times in order to reduce/eliminate coelutions and wraparound. ��� �The mass analyzer must be capable of routine and sustained acquisition with a mass accuracy of 1 ppm or better. This will be in full mass range mode and be independent of acquisition speed or mass range. The mass accuracy should typically apply to any m/z, from a S/N of greater than 100 to a point below saturation with standard data processing methods. ��� �To accommodate the capability for performing GCxGC and ultra-fast GC the system must be capable of acquisition at not less than 200 full mass range, written-to-disk spectra per second. The full range of acquisition speeds must be 1 to 200 spectra per second. ��� �The system must have a spectral dynamic range of at least 105 (100,000) to allow for analysis and detection of isotopes and low level analytes in the acquired spectra, including trace analytes in the presence of high level analytes. Multimode source.� ��� �Multi-Mode Source� (MMS�) is a dual chamber (one for chemical ionization, one for electron ionization) design which can seamlessly switch between 3 modes of ionization (positive and negative chemical ionization and positive electron ionization). PAL3 Series II GC AutoSampler for Liquid and Headspace injections. ��� �A liquid autosampler and static headspace autosampler from a single software platform. Data System and applications software. Delivery and Installation. One-year vendor warranty, including technical support, parts, labor, and travel/shipping from date of installation. The contractor shall conduct training on the operation and maintenance of the complete LECO GC-HRT+ 4D system. This training shall be in sufficient detail such that, once completed, the trainees will have proficiency to operate and maintain the LECO GC-HRT+ 4D system with minimum reliance upon the contractor development team. The contractor shall provide hands-on training for both hardware and software elements of the delivered LECO GC-HRT+ 4D system. This notice of intent is not a request for competitive proposals; however, any firm believing it can fulfill the requirement identified above may submit a written response to be received at the Contracting Office no later than 14 days after the date of publication of this notice, which shall be considered by the agency. The written response shall reference solicitation number N6893624Q0127 and provide a capability statement that clearly indicates the firm�s experience, assets, background, and ability to perform the required work without compromising the quality, accuracy, reliability, and schedule. The Government will consider all information received via email to the Contract Specialist and Contracting Officer by 29 July 2024 at 12:00 PM PST. A determination by the Government not to compete this procurement based upon responses to this notice is solely within the discretion of the Government. The Government will not pay for any information received. No telephone responses will be accepted. Any submissions or questions shall be submitted via email to the point of contacts listed below. Interested firms must be registered in the System for Award Management (SAM) database at https://sam.gov/ to start doing business with the federal government. �
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/59b15c7b50cb4a7db588781f222e51b4/view)
 
Record
SN07128913-F 20240717/240715230113 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.