SOLICITATION NOTICE
Y -- Construct Redundant Electrical Supply, Buckley SFB, CO
- Notice Date
- 7/17/2024 4:58:55 AM
- Notice Type
- Presolicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- W071 ENDIST OMAHA OMAHA NE 68102-4901 USA
- ZIP Code
- 68102-4901
- Solicitation Number
- W9128F24R0066
- Response Due
- 7/17/2024 12:00:00 PM
- Archive Date
- 08/01/2024
- Point of Contact
- Scott Dwyer, Shawn Adkins, Phone: 4029952091
- E-Mail Address
-
Scott.Dwyer@usace.army.mil, shawn.a.adkins@usace.army.mil
(Scott.Dwyer@usace.army.mil, shawn.a.adkins@usace.army.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- An an estimated date of 17 July, 2024, this office will issue a solicitation for Construct Redundant Electrical Supply, Buckley Space Force Base, Colorado. Colorado. This solicitation will use trade-off source selection procedures under Best-value continuum. Proposals will be tentatively due on 21 August 2024. No amount is to be charged for solicitation documents. This soclitation is a SMALL BUSINESS SET-ASIDE. This project will be executed using a design-bid-build (DBB) project delivery method. Estimate of the magnitude of this project is between $5M - $10M. PROJECT DESCRIPTION: This project will replace end of life cable and switchgear considered to be at the end of their useful life and install a redundant, new backup commercial power feed of same capacity to the PL-1, which will improve resiliency by creating the redundancy mandated by Uptime Institute (UTI) Tier IV Standards in accordance with (IAW) Paragraph 12 of AFI 32-062, AFSPC Supplement. This project will also eliminate several existing high risks, single points of failure, any one of which may cause lengthy risk to mission reliability. Listed below are goals for the project: Install a new external ATO feed line for the Replacement and Redundant feeder line to connect to inside the PL-1 area. Will need to source work with local power utility (XCEL). Replace the primary power feed line inside the PL-1 area Provide new redundant power feed line to the PL-1 area. Provide new ATO-Type switchgear lineups Demolish the existing ""igloo"" switchgear area. Remove the existing primary power feed line inside the PL-1 area.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/1fc66779c8e2432b8fb10fb91701c830/view)
- Place of Performance
- Address: Aurora, CO 80011, USA
- Zip Code: 80011
- Country: USA
- Zip Code: 80011
- Record
- SN07131837-F 20240719/240717230119 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |