SOURCES SOUGHT
66 -- Human in vivo tissue oxygen concentration monitor
- Notice Date
- 7/17/2024 5:21:17 AM
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- NATIONAL INSTITUTES OF HEALTH NIDA Bethesda MD 20892 USA
- ZIP Code
- 20892
- Solicitation Number
- 75N95024Q00444_SB
- Response Due
- 7/24/2024 6:00:00 AM
- Archive Date
- 08/08/2024
- Point of Contact
- Patricia da Silva, Phone: 3018271980, KJ Shaikh, Phone: 3014351777
- E-Mail Address
-
patricia.dasilva@nih.gov, KJ.Shaikh@nih.gov
(patricia.dasilva@nih.gov, KJ.Shaikh@nih.gov)
- Description
- This is a Small Business Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding: (1) the availability and capability of qualified small business sources; (2) whether they are small businesses; HUBZone small businesses; service-disabled, veteran-owned small businesses; 8(a) small businesses; veteran-owned small businesses; woman-owned small businesses; or small disadvantaged businesses; (3) their size classification relative to the North American Industry Classification System (NAICS) code for the proposed acquisition; and (4) availability of domestic sources manufactured in the United States in sufficient and reasonably available commercial quantities and of a satisfactory quality. For equipment/supply requirements, responses must include the place of manufacturing (i.e. address if supply/equipment is a domestic end product and include country of manufacture). For equipment/supply requirements, small businesses must also address the size status of the manufacturer under the applicable NAICS code (i.e. address Non-Manufacturer Rule). Your responses to the information requested will assist the Government in determining the appropriate acquisition method, including whether a set-aside is possible. An organization that is not considered a small business under the applicable NAICS code should not submit a response to this notice. This notice is issued to help determine the availability of qualified companies technically capable of meeting the Government requirement and to determine the method of acquisition.� It is not to be construed as a commitment by the Government to issue a solicitation or ultimately award a contract.� Responses will not be considered as proposals or quotes.� No award will be made as a result of this notice.� The Government will NOT be responsible for any costs incurred by the respondents to this notice.� This notice is strictly for research and information purposes only. Background:� The National Institutes of Health (NIH) is the nation�s leading medical research agency and the primary Federal agency whose mission is to seek fundamental knowledge about the nature and behavior of living systems and the application of that knowledge to enhance health, lengthen life, and reduce illness and disability, conducting, supporting, and making medical discoveries that improve people�s health and save lives. The age-associated loss of muscle strength and mass (sarcopenia) is a well-documented phenomenon and is closely associated with frailty and morbidity in the elderly. Current research is focused on comparing the degree to which age-related changes in blood perfusion, neuromuscular control, mitochondrial function, tissue oxygenation and other anatomical and physiological factors contribute to a decline in muscle strength and endurance. While various methods exist to indirectly assess muscle oxygen concentration or to detect relative changes in muscle oxygenation with age or exercise, invasive polarographic sensors (Clark-type electrodes) represent the gold standard for absolute oxygen concentration measurements in human tissue. Because measurements must be performed in human subjects, purchasing a FDA-cleared instrument is greatly preferred for human subject research protection considerations. Literature research indicated the the LICOX tissue oxygen monitor, while marketed for brain tissue oxygenation measurements in neurosurgery, is a reliable, established means of obtaining absolute oxygen concentration data in human muscle tissue. This monitor utilizes pre-sterilized, pre-calibrated, disposable electrodes, which promotes safety while avoiding measurement errors due to incorrect sensor calibration. Purpose and Objectives: The purpose of this requirement is to acquire a Human in vivo tissue oxygen concentration monitor. Literature research indicates the LICOX Brain Tissue Oxygen Monitor; Integra Life Sciences; Model LCX02 (monitor). Project requirements: Equipment must be FDA approved. Please see PURCHASE DESCRIPTION attached to this posting.� Capability statement /information sought. Companies that believe they possess the capabilities to provide the required products or services should submit documentation of their ability to meet each of the project requirements to the Contracting Officer. The capability statement must specifically address each of the project requirements separately.� Additionally, the capability statement should include 1) the total number of employees, 2) the professional qualifications of personnel as it relates to the requirements outlined, 3) any contractor GSA Schedule contracts and/or other government-wide acquisition contracts (GWACs) by which all of the requirements may be met, if applicable, and 4) any other information considered relevant to this program. Capability statements must also include the Company Name, Unique Entity ID from SAM.gov, Physical Address, and Point of Contact Information. The response must include the respondents� technical and administrative points of contact, including names, titles, addresses, telephone and fax numbers, and e-mail addresses. Interested companies are required to identify their type of business, applicable North American Industry Classification System (NAICS) Code, and size standards in accordance with the Small Business Administration. The government requests that no proprietary or confidential business data be submitted in a response to this notice. However, responses that indicate the information therein is proprietary will be properly safeguarded for Government use only. Capability statements must include the name and telephone number of a point of contact having authority and knowledge to discuss responses with Government representatives. Capability statements in response to this market survey that do not provide sufficient information for evaluation will be considered non-responsive. When submitting this information, please reference the solicitation notice number. One (1) copy of the response is required and must be in Microsoft Word or Adobe PDF format using 11-point or 12-point font, 8-1/2� x 11� paper size, with 1� top, bottom, left and right margins, and with single or double spacing. The information submitted must be in and outline format that addresses each of the elements of the project requirement and in the capability statement /information sought paragraphs stated herein.� A cover page and an executive summary may be included but is not required. The response is limited to ten (10) page limit.� The 10-page limit does not include the cover page, executive summary, or references, if requested. All responses to this notice must be submitted electronically to the Contract Specialist and Contracting Officer.� Facsimile responses are NOT accepted. The response must be submitted to Patricia da Silva at the e-mail address patricia.dasilva@nih.gov. The response must be received on or before July 24th, 2024, 09:00 AM, EDT. �Disclaimer and Important Notes:� This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization�s qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a presolicitation synopsis and solicitation may be published in www.sam.gov. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality: No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).�
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/602400311b024e7e9746f9fa1cdd4021/view)
- Place of Performance
- Address: Baltimore, MD 21224, USA
- Zip Code: 21224
- Country: USA
- Zip Code: 21224
- Record
- SN07133029-F 20240719/240717230129 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |