SAMDAILY.US - ISSUE OF JULY 21, 2024 SAM #8272
SOURCES SOUGHT

59 -- CT Scan Uninterrupted Power Supply

Notice Date
7/19/2024 12:53:33 PM
 
Notice Type
Sources Sought
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
 
ZIP Code
98662
 
Solicitation Number
36C26024Q0762
 
Response Due
7/26/2024 12:00:00 PM
 
Archive Date
08/25/2024
 
Point of Contact
Nazanin Kreiner, Contract Specialist, Phone: (208) 429-2033
 
E-Mail Address
nazanin.kreiner@va.gov
(nazanin.kreiner@va.gov)
 
Awardee
null
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following in support of the Jonathan M. Wainwright VAMC Jonathan M. Wainwright VAMC has a need for a 125 kVA Three-Phase, On-Line Double Conversion, Uninterruptible Power Supply (UPS) to be purchased for the computed tomography (CT) scanner at the VHAWWW imaging department. SALIENT CHARACTERISTICS ITEM 125 kVA Three-Phase, On-Line Double Conversion, Uninterruptible Power Supply (UPS) DELIVERY LOCATION & COSTS Jonathan M. Wainwright VAMC ATTN: B86 Construction 77 Wainwright Drive Walla Walla, WA 99362 ACCESSORIES or OPTIONS Staco P/N: FLU-125-00-S Philips Healthcare: 989801210159 INSTALLATION INFO Unit to be installed in B86 as part of construction project prior to relocation of CT system. DIMENSIONS Height: 75 Inches Width: 31.4 Inches Depth: 33.5 Inches Weight: 1,742 Pounds MAINTENANCE NEEDS The UPS will be serviced under the existing CT service contract. No new/additional service contracts will be required to support the UPS. IS TRAINING REQUIRED? No PERFORMANCE REQUIREMENTS Up to 98% Efficient Lower energy costs and carbon footprint Compact & Reliable Requires either front, top or bottom access, so it can be placed against a wall to minimize footprint. Cooler operation extends internal component life. AC Input Performance High input power factor of 0.99. Low input current distortion of <= 3%. Power walk-in function that ensures progressive rectifier start-up. IGBT and Digital Signal Processor (DSP) Reduces the impact of the UPS on the local supply. Simplifies installation where there is limited power capacity in the form of available electrical supply rating or generator size. Dual Input Main power and secondary emergency standby power increase resilience of single or parallel system configuration. High Performance Filter Protects upstream power supply sources from harmonics and reactive power generated by the loads power. Menu Select Display User friendly display is easy to see and intuitive to use. Parallel up to 8 Units Provides redundancy for mission critical applications with no additional hardware. Seismic Certified For environments requiring seismic certification, the P Series UPS is available with an optional OSHPD Certified mounting system which makes the UPS and Battery Cabinet(s) OSHPD Certified. Nationwide Service Program Factor trained service personnel maximize equipment life. Full Two Year Warranty JUSTIFICATION A reliable UPS is required to ensure the operability and integrity of the CT scanning system. The UPS will function for a full 30 minutes after any power loss, allowing the CT scanner to be properly taken off line in the event of prolonged power outages. Additionally, the UPS will filter the power to the CT scanner preventing damage due to dirty power issues and power fluctuations/loss. DEPARTMENT Radiology POWER NEEDS Input Voltage: 480V, 3-Phase Input Current (Max): 160A TECHNOLOGY NEEDS None MATERIAL and COLOR ADDITIONAL INFORMATION Product Information: Link Potential candidates having the capabilities necessary to provide the above stated supplies at a fair and reasonable price are invited to respond to this Sources Sought Notice via e-mail to Nazanin Kreiner at nazanin.kreiner@va.gov no later than July 26, 2024, 1:00PM Mountain Time. No telephone inquiries will be accepted. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: Company name, address, SAM UEI and business size; point of contact name, phone number, and e-mail address; whether services are presently offered on a current GSA Federal Supply Schedule contract. NAICS Code 335311 Size Standard: 800 employees is applicable to determine business size standard. Any questions or concerns may also be directed via email to Nazanin Kreiner at nazanin.kreiner@va.gov. Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/4f5cf5612f274604b6bd13ea55737353/view)
 
Place of Performance
Address: Jonathan M. Wainwright VAMC ATTN: B86 Construction 77 Wainwright Drive, Walla Walla 99362
Zip Code: 99362
 
Record
SN07136554-F 20240721/240719230114 (samdaily.us)
 
Source
SAM.gov Link to This Notice