65 -- MAGPRO X100 STIMULATOR Transcranial Magnetic Stimulator

Notice Date
7/22/2024 10:42:37 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
RPO WEST (36C24W) MCCLELLAN CA 95652 USA
 
ZIP Code
95652
 
Solicitation Number
36C24W24Q0165
 
Response Due
7/26/2024 12:00:00 PM
 
Archive Date
08/10/2024
 
Point of Contact
Sonja Fields, Contract Specialist, Phone: 254-778-4811
 
E-Mail Address
sonja.fields@va.gov
(sonja.fields@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
STATEMENT OF WORK GENERAL: VA San Diego Spinal Cord Injury and Community Living Center has executed a new build that will meet the VA seismic criteria and meet VHA standard for long term care, 3350 La Jolla Village Drive, San Diego, CA 92161, has a requirement for transcranial magnetic stimulation system. The transcranial magnetic system will be used within the SCI clinic. Please submit all quotes to Sonja Fields (Sonja.fields@va.gov) by Friday 26 July 2024 2:00 PM CST. BACKGROUND: The VA San Diego Spinal Cord Injury (SCI) and Community Living Center (CLC) has a requirement for transcranial magnetic stimulation system. PURPOSE: The transcranial magnetic stimulation system is being used as a noninvasive form of brain stimulation in which a changing magnetic field is used to induce an electric current at a specific area of the brain through electromagnetic induction. The device is intended to be used to treat patients meeting clinical criteria for Major Depressive Disorder as defined in the Diagnostic and Statistical Manual of Mental Illnesses. SCOPE: VA San Diego Spinal Cord Injury and Community Living Center is requesting contractors to provide and install brand name or equal equipment that meets or exceed the physical, functional, and performance of the listed salient characteristics in this section. The equipment feature is essential to the technical requirements to meet the need of department. PHYSICAL CHARACTERISTICS: Equipment must have the physical characteristics to enable the government to perform the capabilities: TMS MagVenture Magnetic Stimulator System MagPro X100 with coils Magnetic Stimulator: MagPro X100 with MagOption 9016E0731 High performance magnetic stimulator designed primarily for research. Provide both biphasic and monophasic pulse waveforms, electronically reverse current direction, complex pulse firing patterns, stimulation parameters, theta burst, and high frequency stimulation up to 100 Hz. Possibility to combine waveforms and pulse modes Treatment coil MCF-B65 9016E0423 A butterfly-shaped coil, with static cooling, designed for protocols that require a high number of stimuli without external cooling. Equipped with a trigger button on the handle for ease of operation. Includes super flex arm for coil positioning (9016B0171), MEP Monitor (9016C0711), Isolation Transformer MagPro X/R (9016D0031), and XH Trolley (9016B0712) Quantity: 1 FUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Equipment must provide the functional and performance capability as listed above in section in above. SOFTWARE: N/A INSTALLATION AND TRAINING: Contractor is to provide installation of the equipment. Contractor is to provide a one-time training at installation of equipment. Training sessions will be coordinated with VA POC. WARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment. PERFORMANCE: All items to be delivered after receipt of purchase order not earlier than 12/1/2024 but not later than 12/20/2024. Delivery and receipt of the proposed items is anticipated to be directed to the location identified below. Confirmation of delivery location will be provided by the VA POC post-award. Delivery must be coordinated with VA POC prior to any attempts at delivery. Any item that has not been coordinated will be turned away and any additional charges will be the responsibility of the sender/transportation company. Vendor`s responsibility will include offloading the equipment from the truck, moving the equipment to the correct delivery location in the space, uncrating or unboxing the equipment then removing all trash, and setting up the equipment according to the manufacturer`s specification followed by testing the equipment to verify that it is operational. Equipment installation paperwork & warranty information must be handed to the approved government contact onsite. Vendor shall abide by all rules and regulations set forth by VA San Diego due to Coronavirus (COVID-19) and have their own personal protective equipment (PPE) in use for the time they are on VA San Diego campus grounds. Hours: Normal duty hours are 8:00 a.m. through 4:00 p.m., Monday through Friday, not including federal holidays. Whenever contact with a facility is required outside of normal duty hours, the Contractor shall coordinate these times with the designated COR, POC or designee. In accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following national holidays are observed and for the purpose of this contract are defined as Legal Federal official holidays New Year s Day January 1st Martin Luther King s Birthday Third Monday in January President s Day Last Monday in February Memorial Day Last Monday in May Juneteenth June 19th Independence Day July 4th Labor Day First Monday in September Columbus Day Second Monday in October Veteran s Day November 11th Thanksgiving Day Fourth Thursday in November Christmas Day December 25th Noncontract Charges: The contractor shall not perform any service that will result in additional charges without prior approval from the Contracting Officer. Payment: Payment will be made upon receipt of a properly prepared invoice which references the period for which payment is due, the contract number and/or assigned purchase order number. The invoice must include the correct payment address. Waste Removal: The contractor is responsible for removing and properly disposing of all waste related to the services provided on-site at all VA facilities. Failure to carry out the above procedures will be considered as a failure to document the service visit and will constitute a failure to perform. All shipping for parts will be included in the cost of the contract. PLACE OF DELIVERY: VA San Diego Spinal Cord Injury and Community Living Center 3350 La Jolla Village Drive, San Diego, CA 92161 SECURITY Information Security The vendor shall ensure adequate LAN/Internet, data, information, and system security in accordance with VA standard operating procedures and standard contract language, conditions laws, and regulations. The vendor s firewall and web server shall meet or exceed the government minimum requirements for security. All government data shall be protected behind an approved firewall. Any security violations or attempted violations shall be reported to the VA Project Manager and the VBA Headquarters Information Security Officer as soon as possible. The vendor shall follow all applicable VA policies and procedures governing information security, especially those that pertain to certification accreditation. The contractor shall follow The Veterans Affair Acquisition Regulation (VAAR) security clause VAAR- 852.273-75 SECURITY REQUIREMENTS FOR UNCLASSIFIED INFORMATION TECHNOLOGY RESOURCES sited in section C. Contract Clauses (a) The contractor and their personnel shall be subject to the same Federal laws, regulations, standards, and VA policies as VA personnel, regarding information and information system security. These include but are not limited to the Federal Information Security Management Act (FISMA), Appendix III of OMB Circular A-130, and guidance and standards, available from the Department of Commerce's National Institute of Standards and Technology (NIST). This also includes the use of common security configurations available from NIST's Web site at: http://checklists.nist.gov (b) To ensure that appropriate security controls are in place, Contractors must follow the procedures set forth in ""VA Information and Information System Security/Privacy Requirements for IT Contracts"" located at the following Web site: http://www.iprm.oit.va.gov Contract Personnel Security All contractor employees who require access to the Department of Veterans Affairs' computer systems shall be the subject of a background investigation and must receive a favorable adjudication from the VA Security and Investigations Center (07C). The level of background security investigation will be in accordance with VA Directive 0710 dated September 10, 2004, and is available at: http://www.va.gov/pubs/asp/edsdirec.asp (VA Handbook 0710, Appendix A, Tables 1 - 3). Appropriate Background Investigation (BI) forms will be provided upon contract (or task order) award and are to be completed and returned to the VA Security and Investigations Center (07C) within 30 days for processing. Contractors will be notified by 07C when the BI has been completed and adjudicated. These requirements are applicable to all subcontractor personnel requiring the same access. If the security clearance investigation is not completed prior to the start date of the contract, the employee may work on the contract while the security clearance is being processed, but the contractor will be responsible for the actions of those individuals they provide to perform work for the VA. In the event that damage arises from work performed by contractor personnel, under the auspices of the contract, the contractor will be responsible for resources necessary to remedy the incident. Project Name: San Diego SCI/CLC Project Location: Cat Code: VV JSN: M8173A Date Prepared: October 26, 2023 Brand Name or Equal Nomenclature: Transcranial Magnetic Stimulator Manufacturer: MagVenture Inc. Model Name: MagPro X100 System Dealer: Model Number: MagPro X100 Email: infousa@magventure.com 3rd Party Install: No Room Nbr(s): See Attached Phone: 1-888-624-7764 Dimensions: D 16.00 in W 9.00 in H 8.50 in D 406.4 mm W 228.6 mm H 215.9 mm 1: Plumbing: 7: Data: No 2: Electrical: SPECIAL ELECTRICAL REQUIREMENTS 8: Drops: DC: No EP: No Addl Outlets: Amps: Outlet Type: 9: Warranty: 2 yr 3: Medical Gas: 10: Training: Yes 4: Misc Gas: 11: Weight: 146.00 5: NonMed Gas: 12: Wall Blocking: No 6: Misc: Salient Characteristics A high performance magnetic stimulator primarily for research. The MagPro X100 with MagOption offers a wide range of stimulation parameters, theta burst and stimulation rates up to 100 Hz, and the possibility to combine waveforms and pulse modes. With the same features as the MagPro X100, it also provides half-sine waveforms, twin and dual pulses up to 50 pps (biphasic) and has a power mode with a 40% increase in intensity and pulse width. Diagnostic Use: The MagProX100 with MagOption is intended as an electro-physiological aid to assess diagnosis and to monitor diseases of the central and peripheral nervous system, based on the use of Motor Evoked Potentials (MEP). Therapeutic Use: Treatment of Major Depressive Disorder in adult patients who have failed to achieve satisfactory improvement from two prior antidepressant medications, at or above the minimal effective dose and duration in the current episode. System must consist of the following items as Basis Of Design (Meet or exceed) for effective treatment: -P/N 9016E0731: MagPro X100 with MagOption -P/N 9016E0423: Coil MCF-B65 -P/N 9016B0171: Super Flex Arm for Coil Positioning (long) -P/N 9016C0711: MEP Monitor Option (with 1.5mm cable and pack of electrodes) -P/N 9016D0031: Isolation Transformer MagPro X/R System -P/N 9016B0712: XH Trolley for MagPro & coil holder accessories Project Name: San Diego SCI/CLC Project Location: Cat Code: VV JSN: M8173A Date Prepared: October 26, 2023 Image Finishes/Options
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/27b94447cfe545a1bf05c0873db0e982/view)
 
Place of Performance
Address: Department of Veterans Affairs San Diego Spinal Cord Injury& Community Living CT 3350 La Jolla Village Drive, San Diego 92161, USA
Zip Code: 92161
Country: USA
 
Record
SN07138229-F 20240724/240722230120 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.