Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 28, 2024 SAM #8279
SOURCES SOUGHT

J -- BOILER PLANT SERVICES FAYETTEVILLE VAMC

Notice Date
7/26/2024 4:28:05 AM
 
Notice Type
Sources Sought
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
 
ZIP Code
23667
 
Solicitation Number
36C24624Q1161
 
Response Due
7/31/2024 7:00:00 AM
 
Archive Date
09/29/2024
 
Point of Contact
Crystal Perry, Contract Specialist, Phone: TBD
 
E-Mail Address
Crystal.Perry4@va.gov
(Crystal.Perry4@va.gov)
 
Awardee
null
 
Description
The purpose of this notice is to conduct market research and obtain information from qualified potential offerors. No formal solicitation document exists at this time. The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. The Department of Veterans Affairs Administration, Fayetteville VA Medical Center, located at 2300 Ramsey Street, Fayetteville, N.C 28301 has need of a contractor who can provide all necessary labor, equipment, tools, materials, parts, etc. for complete annual internal inspection, semi-annual tuning, testing, calibrating, adjustments of boiler equipment and boiler plant controls. Below is a summarized description of the required boiler services. A qualified testing contractor is an individual/company that has performed testing in compliance with the attachment (A)-VHA Boiler and Associated Plant Safety Device Testing Manual in at least three other VA medical facilities. Any conflict with the SOW or other reference codes, the latest edition of BEI will govern. A qualified Professional Inspectors as defined below shall perform internal and external inspections on high pressure (over 15 psig) steam boilers and internal inspections on feedwater deaerators and other pressure vessels. Non-destructive testing of feedwater deaerator pressure vessels shall be performed by certified non-destructive testing technicians as defined below under the guidance of the Qualified Professional Inspector. The qualified contractor shall furnish all necessary labor, equipment, tools materials, parts, etc., for complete annual internal inspection, semi-annual tuning, testing, calibrating, adjustments of boiler burners, boiler equipment and boiler plant as specified below in accordance with the terms and conditions and schedule of this SOW. The contractor must complete inspection, tuning, testing, calibrating, and adjustments or burners and boiler and boiler plant controls as specified below: Inspection and calibration cannot be scheduled during hours of heavy steam load periods. Only one boiler at a time can be out of service for the inspection, testing and calibration procedures. Semiannually instrumentation, monitoring and data management systems shall be coordinated and completed when the COR or his/her designee is available on-site to monitor work progress. The contractor shall provide inspection, testing and calibration services for boiler plant safety devices in accordance with requirements contained herein for the following list of equipment. All 3 boilers are certified by Johnston Boiler Company Descriptions Boiler #1 Boiler #2 Boiler #3 National Board 10448 10449 10450 Serial 10510-01 10510-02 10510-03 Year 2005 2005 2005 Design Pressure (PSI) 200 200 200 Steam Output (PPH) 13800 13800 13800 Natural Gas (SCFH) 13361 13361 13361 #2 Fuel Oil Input (GPH) 112 112 112 Technician Qualifications: Technicians shall have completed at least a one-year trade school and have five years successful experience in this field. The experience shall be largely with institutional and industrial boiler plants similar in design to the FVAMC plant. The FVAMC facility manager/engineer may define and accept equivalent qualifications. The anticipated NAICS CODE FOR THIS PROCUREMENT IS 238220, Plumbing, Heating, and Air-Conditioning. Responses to this sources sought notice should include the following: name and address of company, business size (large or small): identify whether or not firm falls into any of the following socioeconomic categories-8(a), HUBZone, Services Disabled Veteran Owned/Veteran-Owned Small Business; provide a brief description of qualifications and any other pertinent information which demonstrates the ability to meet the above requirement. Subject line must reflect: Boiler Services Fayetteville NC. All responses shall be submitted in writing no later than 10:00 AM, Wednesday, July 31, 2024, to the attention of: Crystal Perry at Crystal.Perry4@va.gov.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/09bd79f049df431bbc39c3b408af8072/view)
 
Place of Performance
Address: Fayetteville VA Medical Center 2300 Ramsey Street, Fayetteville 28301
Zip Code: 28301
 
Record
SN07145850-F 20240728/240726230121 (samdaily.us)
 