SOLICITATION NOTICE
Z -- John Day Generator Cooling Water System Rehab
- Notice Date
- 8/22/2024 2:05:07 PM
- Notice Type
- Presolicitation
- NAICS
- 237990
— Other Heavy and Civil Engineering Construction
- Contracting Office
- W071 ENDIST PORTLAND PORTLAND OR 97204-3495 USA
- ZIP Code
- 97204-3495
- Solicitation Number
- W9127N24R0006
- Response Due
- 9/5/2024 10:00:00 AM
- Archive Date
- 09/20/2024
- Point of Contact
- Andrew Sprys, Andrea Smothers
- E-Mail Address
-
andrew.j.sprys@usace.army.mil, andrea.k.smothers@usace.army.mil
(andrew.j.sprys@usace.army.mil, andrea.k.smothers@usace.army.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- SYNOPSIS The U.S. Army Corps of Engineers (USACE) Portland District is soliciting a Contract for the John Day Generator Cooling Water System Rehab at John Day Dam, Rufus, Oregon. The proposed project will be a competitive, firm-fixed price (FFP) contract. Project Scope: The U.S. Army Corps of Engineers, Portland District, has a requirement to replace generator air cooler, header and drain piping. The work also includes the installation of modulating valves and associated controls to generator air cooler and thrust bearing discharge heard lines as well as replacing existing flow gauges for the generator air coolers and thrust bearing coolers with ultrasonic or electromagnetic technology. The described work is to be conducted on 16 units. Background: The John Day Powerhouse is located on the Columbia River, 112 miles east of Portland, Oregon, and is the third largest hydro-electric facility in the United States, with its 16 generators having a total capacity of 2408MW. The powerhouse lies on the border between Oregon and Washington. Units 1 to 14 are in Oregon while Units 15 and 16 are in Washington. This project is being performed to prevent or reduce water infiltration into the main unit generator windings to eliminate future failures. Since 2014, three main unit generators at John Day Powerhouse have experienced winding failures on startup that have been linked back to water infiltration into the generator windings. The purpose of this project is to minimize water leaks in the generator barrel, reduce condensation and improve water drainage. Water leaks from the generator air cooler vent pipes will be eliminated by replacing the problematic � inch overhead copper piping. This piping will be replaced with stainless tubing using compression or flared type connections. Soldered connections directly over the air coolers will be replace with flexible hose. This will reduce possible leak points and eliminate vent port alignment issues when swapping out coolers. The main units were designed without modulating or automatic shut off valves, despite modulating valves being standard on other government dams at time of John Day construction. Condensation will be reduced by adding modulation valves to the generator air cooler and thrust bearing oil cooler water discharge. Also, discharge flow meters will be replaced with new to eliminate the costly calibration issues with the existing devices. These modulating valves and flow meters will require associated controls and PLCs to integrate into the existing DDC system. Contract Period of Performance: The estimated Period of Performance for this contract is 742 days after Notice to Proceed Magnitude of Construction: The estimated cost of the project is $5,000,000 to $10,000,000. Set Asides and Codes: Full and Open Competition - Unrestricted. The North American Industrial Classification Code (NAICS) for this potential requirement would be 237990, �Other Heavy and Civil Engineering Construction�. The related size standard is $45M. The Product Service Code (PSC) is Z1KA - Maintenance of Dams. Selection Process: This is an total small business competitive acquisition using Best Value Tradeoff (BVTO) source selection procedures.� The Government intends to award a single, firm-fixed-price construction contract to the responsible offeror whose proposal represents the best value after evaluation in accordance with the evaluation factors in the solicitation.� Offerors shall submit a non-price proposal and a price proposal. The evaluation results of the non-price and price proposals will determine an awardee. All non-price factors are approximately equal in importance.� All non-price evaluation factors, when combined, are approximately equal to price. The Government reserves the right to accept other than the lowest-priced offeror or to reject all offers. Discussions: The government intends to award without discussions but reserves the right to conduct discussions if deemed to be in the government�s best interest. Anticipated Solicitation Release Date: The government anticipates releasing the solicitation in September 2024. The closing date for proposals will be approximately 30 days later. Actual dates and times will be identified in the solicitation. Responses to this synopsis are not required. Additional details may be found in the solicitation when it is posted. System for Award Management (SAM): Offerors must register in the SAM at https://www.sam.gov/portal/public/SAM/ prior to submission of bids and prior to receiving an award. Point of Contact: The USACE-NWP points of contact for this action are Andrew Sprys at andrew.j.sprys@usace.army.mil and Andrea Smothers at andrea.k.smothers@usace.army.mil. Email is the only method for receiving responses to this pre-solicitation notice. Point of Contact for small business questions or assistance is the Portland District Deputy for Small Business, Carol McIntyre at 503-808-4602 or Carol.A.Mcintyre@usace.army.mil. THIS PRE-SOLICITATION NOTICE IS FOR THE PURPOSE OF INFORMING INDUSTRY THAT THIS SOLICITATION WILL BE POSTED ON SAM ON OR ABOUT 12 JUNE 2023. THIS NOTICE IS NOT A REQUEST FOR PROPOSALS AND PROPOSALS RECEIVED AS A RESULT OF THIS PRE-SOLICITATION NOTICE WILL NOT BE ACCEPTED OR EVALUATED. THE GOVERNMENT RESERVES THE RIGHT TO CANCEL THIS SOLICITATION EITHER BEFORE OR AFTER THE CLOSING DATE. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS PRESOLICITATION NOTICE OR ANY FOLLOW-UP INFORMATION REQUEST.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/dc50eb38cb7440c8ab90956489aa334d/view)
- Place of Performance
- Address: Rufus, OR 97050, USA
- Zip Code: 97050
- Country: USA
- Zip Code: 97050
- Record