SOURCES SOUGHT

J -- UPS PM 623-25-1-5064-0042

Notice Date
2/5/2025 7:06:28 AM
 
Notice Type
Sources Sought
 
NAICS
811210 —
 
Contracting Office
NETWORK CONTRACT OFFICE 19 (36C259) Greenwood Village CO 80111 USA
 
ZIP Code
80111
 
Solicitation Number
36C25925Q0178
 
Response Due
2/11/2025 1:00:00 PM
 
Archive Date
05/12/2025
 
Point of Contact
Tiffani Perkins, Contract Specialist, Phone: 918-577-3261
 
E-Mail Address
Tiffani.Perkins@va.gov
(Tiffani.Perkins@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
Performance Work Statement (PWS) Uninterruptible Power Supply Preventative Maintenance Department of Veterans Affairs (VA) Veterans Health Administration (VHA) (Brief Scope of Work) PURPOSE Veterans Affairs has a requirement for Uninterruptible Power Supply Preventative Maintenance services at the Eastern Oklahoma VA Health Care System (EOVAHCS). Services are to be performed in accordance with this PWS and to OEM standards, with the intent of ensuring the equipment operates as the original manufacturer intended, uninterrupted (95% uptime), in a cost-effective, efficient manner, contributing to the VA Mission. This is a non-personal services contract. The Contractor, its employees, agents and subcontractors shall not be considered VA employees for any purpose of fulfilling the SOW and shall be considered employees of the Contractor. C&A requirements do not apply, and a Security Accreditation Package is not required. LOCATION: Eastern Oklahoma VA Health Care System (EOVAHCS) 921 NE 13th St. Oklahoma City, OK 73104 TASKS AND REQUIREMENTS: Title of Project: Eaton Three Phase Uninterruptable Power Supply (UPS) Service Plan. Scope of Work: The contractor shall provide inspection and preventative maintenance on the Power Module and batteries annually. Battery replacement is not included. The UPS is located in building 22 at the Jack C. Montgomery VAMC. The C&A requirements do not apply, and a Security Accreditation Package is not required. Services include: 7x24 Emergency Service Coverage including parts, labor and travel Annual 5x8 Preventive Maintenance Inspection Annual 5x8 Comprehensive Battery Inspection Eight (8) Hour (maximum) Response Time Web Access to Service History Background: UPS is utilized at the Jack C. Montgomery VA Medical Center to prevent any power fluctuations that may affect any computer equipment in the server room. Equipment to be covered is: Eaton 9355-30 Serial Number EA024KXX10 Description of Tasks and Associated Deliverables: The contractor shall provide inspection of all UPS components and batteries in accordance with manufacturer s recommendations. If for any reason, any deliverable cannot be delivered on time according to the below schedule, the contractor shall provide a written explanation three days prior to the due date to the Contracting Officers Representative (COR). This written transmittal shall include a firm commitment of when the work shall be completed. This transmittal shall include a firm commitment of when the work shall be completed. This transmittal to the COR shall cite reasons for the delay and the impact on the overall project. The COR will review and issue a response in accordance with the contract terms and conditions. Specifically, the contractor shall: Task One: The contractor shall inspect all UPS components in accordance with manufacturer s recommendations. Corrective Maintenance Coverage: Inspection and repair of the electronic portion of the UPS (or other equipment type), or Power Module Deliverable One: Visual Inspection Inspect all printed circuit board connections for cleanliness, swab contacts if necessary. Inspect all power connections for signs of overheating. Inspect all subassemblies, bridges and legs for signs of component defects or stress. Inspect all DC capacitors for signs of leakage. Inspect all AC capacitors for sings of leakage. Inspect and inventory all customer-owned spare parts. Inspect for, and perform as required, any open engineering changes. Internal Operating Parameters DC Ground Detection Offset (if applicable) Inverter leg current average balance (if applicable) Output filter current average phase balance Rectifier bridge current average leg balance AC Protection settings are checked DC Protection settings are checked Input and Output Frequency and Voltage Bandwidth settings are checked Verify DC filter capacitance Verify AC tank and trap filter capacitance Power Supply voltages and waveforms External Operating Parameters System Input Voltages (all phases) System Input Currents (all phases) DC Charging Voltages (float and equalize), record settings, adjust to nominal Rectifier phase on and walk up Inverter phase on and walk up Adjust all panel meters to measured values System Bypass Voltages (all phases) Manual and UV Transfer testing, verify uninterrupted transfer waveform (if applicable) Outage simulation and battery capability testing and verify charger current limit Generator operation and interface verification (if applicable) Environmental Parameters UPS area ambient temperature and condition of ventilating equipment General Cleanliness of UPS Power Module General Cleanliness of UPS area Replace all air filters Clean control panel/CRT screen Flywheel only: Drain oil and change oil and filters Battery Cabinet Checks General appearance of Battery System General cleanliness of Battery system area Inspect cells for physical abnormalities Inspect all DC connections for abnormalities Battery system area ambient temperature and condition of ventilating equipment For internal batteries only, measure and record: Overall battery float voltage Charger input current and voltage Negative terminal temperature of one cell/battery per battery cabinet shelf or rack tier Monitoring System Parameters Alarm archive review and printing Alarm lamp test-local and remote (if applicable) Replace all open monitor bulbs Review battery test in history (if applicable) General Customer Consultation Verbal Recommendations General Observations Task Two: The contractor shall inspect all UPS batteries in accordance with manufacturer s recommendations Deliverable Two: Measure and Record Battery performance Individual cell/battery float voltages and overall float voltage Charger output current and voltage AC ripple current and voltage imposed on battery Internal ohmic values of each cell/battery or perform a continuity test of each cell/battery Connection Resistance of 10% of the inter cell/battery connection Ambient temperature Negative terminal temperature of one cell/battery per battery cabinet shelf or rack tier Visually inspect conditions and appearance of the following Connection terminal inter cell/battery connectors, cables and associated hardware Cell/battery covers, containers and post seals Battery racks or cabinets and associated components and hardware Cell/battery jar or cover, noting any excessive distortion Perform cleaning of all accessible surfaces as required Measure and record the connection resistance of 100% of the inter cell/battery connections yearly Re-torque any connection where the resistance is above 20% of the average yearly The technician(s) will issue the customer a verbal report summarizing the condition of the battery and identifying any critical issues before leaving the customer s site. A detailed report containing all reading and observations will be sent to the customer within 5 business days Technical support 7x24: technical support via telephone or email. Contractor shall be available to answer product or support questions. Attachment A Schedule of Deliverables Deliverable No. Task 1 Item Visual Inspection Delivery Date Within 30 days after contract award Task 1 Internal Operating Parameters Within 30 days after contract award Task 1 External Operating Parameters Within 30 days after contract award Task 1 Battery Cabinet Checks Within 30 days after contract award Task 1 Monitoring System Parameters Within 30 days after contract award Task 1 General Within 30 days after contract award Task 2 Measure and Record Battery Performance Within 30 days after contract award Task 2 Visually inspect conditions and appearance Within 30 days after contract award Task 2 Technical Support 7 x 24 At contract award IMPORTANT NOTE: This Sources Sought is for information only (to determine the socioeconomic status of interested companies). No award will be made off of this posting. LIMITATIONS OF SUBCONTRACTING: The Limitations of Subcontracting may or may not apply to a resulting solicitation from this Market Research. Vendors are advised to familiarize themselves with Federal Acquisition Regulation parts 19.505(a)(2) and 19.505(b)(1) as it pertains to subcontracting limitations. Vendors are also advised to familiarize themselves with 13 CFR 125.6 and the penalties described in this regulation. Please communicate via e-mail to tiffani.perkins@va.gov by COB 2/11/2025 as to your company s interest and ability to perform service per this brief Scope of Work. If interested, please provide the following: Please state your company s business size as related to NAICS code 811210 As per the Limitations of Subcontracting: (see FAR 19.505) As Primary Contractor: what % of Total Contract Value will you retain? If using a Subcontractor: what % of Total Contract Value will go to them? Please provide SAMs Unique Entity Identifier number If you have an FSS/GSA contract that includes this service Provide FSS/GSA contract number if applicable � In order for you company s information to be counted in relation to this Market Research all above questions must be answered.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/df6a425bccec42c3a478b327d4c95ce5/view)
 
Place of Performance
Address: Department of Veterans Affairs Eastern Oklahoma VA Health Care System 1011 Honor Heights Drive, Muskogee, OK 74401, USA
Zip Code: 74401
Country: USA
 
Record
SN07334119-F 20250207/250205230038 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.