SOLICITATION NOTICE
J -- USCGC Alder Fire Main Repair
- Notice Date
- 12/3/2025 8:48:54 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 336611
— Ship Building and Repairing
- Contracting Office
- SFLC PROCUREMENT BRANCH 2(00085) ALAMEDA CA 94501 USA
- ZIP Code
- 94501
- Solicitation Number
- 70Z08526Q0001432
- Response Due
- 12/10/2025 8:00:00 AM
- Archive Date
- 12/25/2025
- Point of Contact
- Justin Wooldridge, Phone: 2068205327, Lindsay Mongiovi, Phone: 5716086752
- E-Mail Address
-
justin.r.wooldridge2@uscg.mil, lindsay.n.mongiovi@uscg.mil
(justin.r.wooldridge2@uscg.mil, lindsay.n.mongiovi@uscg.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- Statement of Work USCGC ALDER (WLB 216) Fire Main Piping Crop & Renew 1. Purpose and Scope � KTR shall renew firemain piping located in compartment 1-12-1-L, Passage. 2. Deliverables and Performance Requirements � Protective measures: The KTR must furnish and install all protective measures IAW SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection). � Interferences: The KTR must handle all interferences IAW SFLC Std Spec0000, (Interferences). � Contamination prevention: The KTR must take all precautions to prevent contamination of personnel and spaces IAW all applicable Federal, state, and local regulations. � Fluid handling: The KTR must remove and dispose of removed fluids from the affected piping system, IAW all applicable Federal, state, and local regulations. Do not drain any fluids into any spaced, bilge, or exterior location. � Piping renewal particulars: The KTR must accomplish the following tasks, using Coast Guard Drawing 225�WLB�521�001, REV F as guidance: o Crop out necessary length of piping (6� diameter), to include all necessary FPL supply (3� diameter) and pressure gauge/sensor supply (1/4� diameter) piping. o Fabricate necessary piping arrangement previously cropped IAW CG Drawing. o Install all fabricated piping to include all required gaskets/seals IAW CG Drawing. o KTR must provide a means of sealing any open piping while any portion of the system is open (i.e.: upstream valve blind flange). � Pipe hangers: Furnish, fit, and install new pipe hangers, as necessary. � Pipe labeling: The KTR must label affected piping as follows: o Name of the piping system service. o Destination, where feasible. o Direction of flow, indicated by an arrow three inches long pointing away from the lettering. � Leak Test: After completing all authorized mechanical (i.e. threaded, bolted, etc.) joint repairs, the Contractor must test the affected piping system's operation using the system fluid at normal operating pressure. Ensure zero visible leakage from or deformation of mechanical parts by repairing all leaks and discrepancies. � Touch-up preservation: The KTR must prepare and coat all new and disturbed surfaces to match existing adjacent surfaces in accordance with SFLC Std Spec 6310, (Touch-ups and minor coating repairs.) � Piping insulation installation: The KTR must install new insulation materials over the exposed pipe surfaces at thicknesses appropriate to the application and temperature ranges specified in ASTM F683 Tables. o Associated pipe hangers o Valves o Fittings o Flanges 3. Period of Performance � ALDER is available during the following dates: o 17 December 2025 � 10 January 2026 o 08 February � 07 March 2026. 4. Location and Method of Performance � Guard Sector San Francisco 1 Yerba Buena Island San Francisco, CA 94130 5. Roles and Responsibilities � KTR shall provide Marine Chemist to include certification and all associated documentation for initial certification for hot work. � KTR shall provide competent person to include certification and all associated documentation for recertification for hot work. � KTR shall notify USCGC ALDER POC of any planned hot work prior to COB the day prior to planned hot work. � USCGC ALDER shall provide all necessary fire watches during working hours (0700-1500). � KTR shall provide all necessary fire watches after working hours. 6. Acceptance Criteria � N/A 7. Security and Confidentiality � KTR shall provide: o State Issued Identification numbers to include issuing state for all personnel o Vehicle license plate number to include issuing state for all KTR vehicles o Each vehicle year, make, and model 8. Reporting Requirements � N/A 9. Legal Compliance � KTR shall comply with all applicable Federal, State, and Local laws and regulations. 10. Performance Monitoring � N/A
- Web Link
-
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/a3609bf9a8174224b921b68c4a6baa92/view)
- Place of Performance
- Address: San Francisco, CA 94130, USA
- Zip Code: 94130
- Country: USA
- Zip Code: 94130
- Record
- SN07656189-F 20251205/251203230033 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |