Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 06, 2025 SAM #8776
SOLICITATION NOTICE

20 -- USCGC BERTHOLF EXHAUST COMMERCIAL CLEANING

Notice Date
12/4/2025 9:16:38 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
SFLC PROCUREMENT BRANCH 2(00085) ALAMEDA CA 94501 USA
 
ZIP Code
94501
 
Solicitation Number
70Z08526Q0000771
 
Response Due
12/10/2025 8:00:00 AM
 
Archive Date
12/25/2025
 
Point of Contact
DONNA O'NEAL, Phone: 5103931145, ULISES BALMACEDA, Phone: 2068200307
 
E-Mail Address
Donna.J.O'Neal@uscg.mil, Ulises.O.Balmaceda@uscg.mil
(Donna.J.O'Neal@uscg.mil, Ulises.O.Balmaceda@uscg.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
Greetings all, This modification is to clarify a question to this post. Please see below: In response to the inquiries: 1_ Yes, a site visit is permitted, and it can be scheduled with me. 2- To get access to the base, visitors are required to fill the attached form for a background investigation ( 24 hours ) and send it back to me. They should be cleared at the gate as long as they have a real ID and it matches the information in the form. BASE ACCESS LIST.xlsx 2.1 Once cleared (usually 24 hours), you could pick date & time for the visit. We�ll provide instructions on where to go and who will provide the escort onboard. 3- No, we can only provide the Coast Guard drawings. POC: MKCM Armando Perez Asset Manager SFLC � LRE � Product Line 1 Eagle Rd ALAMEDA, CA Work Cell: (510) 418-2223 This is a combined synopsis/solicitation This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z08526Q0000771 and is issued as a request for quotations (RFQ). This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before 0800 Pacific Time, December 10th, 2025, and will be reviewed by the Government. The United States Coast Guard Surface Force Logistics Center has a requirement for the following: Contractor shall provide parts requested for USCGC BERTHOLF Exhaust Piping Commercial clean: 25902_0316_FLT REC_25902_FLT_�REC� ITEM 1: Ship Service Diesel Generator, Exhaust Piping, Commercial Clean 1. SCOPE 1.1 Intent. This work item describes the requirements for the Contractor to clean exhaust piping of Ship Service Diesel Generator (SSDG) sets listed in Table 1, including the associated stack uptakes. TABLE 1� Ship Service Diesel GeneratoRs CATERPILLAR mODEL NO. DESCRIPTION location 3512B No.1 Ship Service Diesel Generator,1360 KW, 450 Volt AC, 3 Phase, 60 Hz Auxiliary Main Machinery Room (5-36-01-E) 3512B No.2 Ship Service Diesel Generator,1360 KW, 450 Volt AC, 3 Phase, 60 Hz Forward Main Machinery Room (5-44-01-E) 1.2 Government-furnished property. None. 2. REFERENCES Coast Guard Drawings Coast Guard Drawing 750-WMSL-259-003, Rev G, Main Prop Dsl / Ss Dsl Gen Air Intake / Exhaust Diagram (ASC259002) Coast Guard Drawing 750-WMSL-259-004, Rev -, Main Prop Dsl / Ss Dsl Gen Air Intake / Exhaust System Description (ASC259002-02) Coast Guard Drawing 750-WMSL-259-011, Rev D, Main Engine Combustion Air Intake & Exhaust Arr, Dets & L/M Below 2nd Deck (ASC259009) Coast Guard Drawing 750-WMSL-259-013, Rev B, Main Engine Combustion Air Intake & Exhaust Arr, Dets & L/M 2nd Deck Up - 02 Lvl (ASC259011) Coast Guard Drawing 750-WMSL-259-014, Rev C, Main Engine Combustion Air Intake & Exhaust Supports, Dets & L/M 2nd Deck Up - 02 Lvl (ASC259012) Coast Guard Drawing 750-WMSL-259-019, Rev G, Incin & Dg Intake & Combustion Exhaust Arr, Dets & L/M, 2nd Dk - 02 Lvl (ASC259017) Coast Guard Drawing 750-WMSL-259-020, Rev D, Incin & Dg Intake & Combustion Exhaust Sup, Dets & L/M 2nd Deck - 02 Lvl (ASC259018) Coast Guard Publications Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures Surface Forces Logistics Center Standard Specification 8636 (SFLC Std Spec 8636), 2022, Temporary Hull Accesses Other References Code of Federal Regulations (CFR) Title 29, Part 1915, 2014, Occupational Safety and Health Standards for Shipyard Employment 3. REQUIREMENTS 3.1 General. 3.1.1 CIR. None. 3.1.2 Tech Rep. Not applicable. 3.1.3 Protective measures. The Contractor shall furnish and install all protective coverings to seal off and protect all non-affected vessel's components, equipment, and spaces near the work area against contamination during the performance of work. Upon completion of work, the Contractor shall remove all installed protective measures, inspect for the presence of contamination, and return all contaminated equipment, components, and spaces to original condition of cleanliness. 3.1.4 Interferences. The Contractor shall handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences). Known interferences include, but are not limited to the following: Access covers Exhaust stack SSDG Vent ducting Wiring Exhaust pipe expansion joints Exhaust insulation blankets 3.2 Staging or scaffolding. The Contractor shall erect suitable staging or scaffolding in accordance with 29 CFR 1915, Subpart E (Scaffolds, Ladders and Other Working Surfaces) to facilitate work, as required. 3.3 Safety precaution. The Contractor shall rig suitable safety netting, to protect workers during possible falls, and to protect the Engine Room and machinery from falling tools. 3.3.1 Temporary safety railing. To promote safety, the Contractor shall limit existing safety railing removals to an area where new safety railing can be installed during the same workday. During periods when not actively working on new safety railing, secure any gaps between existing safety railing with a substantial temporary lifeline arrangement similar to that currently installed on the vessel. Remove and dispose of all temporary lifelines upon completion of work. 3.4 Work plan. The Contractor shall develop and submit a plan for collecting and disposing of waste extracted during cleaning process. Ensure that the proposed plan shall detail how and where exhaust piping will be disconnected, how entire length of exhaust piping will be divided/sectioned for cleaning, and precautions to protect the SSDGs. One SSDG must remain operational at all times. The Contractor shall perform this work upon receiving Coast Guard approval of the plan. The work plan should be submitted with the proposal / bid. 3.4.1 Due to limited access to work areas, the Contractor may, with express permission of the KO (via submission of a CFR), cut access holes to facilitate accomplishment of the work specified herein. Perform all work required to open and close the access openings in accordance with SFLC Std Spec 8636. note Coast Guard personnel will operate all shipboard machinery and equipment. 3.5 Operational test, initial. Prior to commencement of work, the Contractor shall witness Coast Guard personnel perform an initial operational test of the exhaust piping system, to demonstrate existing operational condition. Submit a CFR. 3.6 Cleaning. The Contractor shall clean the interior surfaces of the exhaust piping and stack uptakes to the SSDGs, shown on Coast Guard Drawing(s) 750-WMSL-259-003,750-WMSL-259-004, 750-WMSL-259-011, 750-WMSL-259-013, 750-WMSL-259-014, 750-WMSL-259-019, and 750-WMSL-259-020 to a condition free from soot, tar, and any other foreign matter as follows: 3.6.1 Disconnect the exhaust piping as necessary to facilitate cleaning. 3.6.2 Thoroughly sweep, mechanically clean, and vacuum the interior of each exhaust pipe system, including the mufflers, from the exhaust outlet to the topmost location outside the vessel. Clean all adjacent stack uptake surfaces. Ensure that all tar deposits, soot deposits, and all other surface contaminants are completely removed. 3.6.3 Remove all debris from the pipe surfaces, stack deck, and Engine Room areas by vacuuming. Dispose of all cleaning materials and generated debris in accordance with all applicable Federal, state, and local regulations. 3.6.4 Reassemble exhaust piping; renew all disturbed flange connection gaskets with suitable high temperature, non-asbestos-containing gasket materials. Gasket material for flanges shall be Flexitallic thermiculite , CRES 316 Core, Max Service Temp 1450 deg F, Flexitallic or equal, 1/8� thick gasket (Item # 58, 750-WMSL-259-019). Renew all flange nuts and bolts. Renew all disturbed fasteners. 3.7 Inspection and report. The Contractor shall perform a visual inspection of the following components; submit a CFR with photographic/video evidence of cleanliness: Exhaust stack access hatches, including all associated studs and nuts. All cleaned exhaust stack surfaces. All exhaust expansion joints, including associated bolts. 3.7.1 Following cleaning of the interior of each exhaust pipe system, the Contractor shall demonstrate completeness of the cleaning process to the Coast Guard Inspector, showing that the entire length of exhaust piping has been satisfactorily cleaned according to the work plan. 3.8 Touch-up preservation. The Contractor shall prepare and coat all new and disturbed surfaces to match existing adjacent surfaces in accordance with SFLC Std Spec 6310, paragraph 3.1.13 (Touch-ups and minor coating repairs). NOTE Coast Guard personnel will operate all shipboard machinery and equipment. 3.9 Operational test, post repairs. After completion of work, the Contractor shall thoroughly test, in the presence of the Coast Guard Inspector and demonstrate the SSDG exhaust piping system to be in satisfactory operating condition. Submit a CFR. 4.0 Location / POC. USCGC BERTHOLF 1 Eagle Rd. Alameda, CA 94501 POC: MKCM Armando Perez (510) 418-2223 4. NOTES This section is not applicable to this work item.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/ebd08da4cd4740228e4f42554e2cbc10/view)
 
Place of Performance
Address: Alameda, CA 94501, USA
Zip Code: 94501
Country: USA
 
Record
SN07657678-F 20251206/251204230036 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.