SOURCES SOUGHT
66 -- BioPlex 2200 supplies
- Notice Date
- 12/4/2025 5:21:24 AM
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- 246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
- ZIP Code
- 23667
- Solicitation Number
- 36C24626Q0160
- Response Due
- 12/8/2025 9:00:00 AM
- Archive Date
- 12/23/2025
- Point of Contact
- Byron Brown, Contracting Officer, Phone: None
- E-Mail Address
-
Byron.Brown4@va.gov
(Byron.Brown4@va.gov)
- Awardee
- null
- Description
- The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of Durham VA Medical Center is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses, capable of providing BioRad BioPlex 2200 analyzer and supplies, but not limited to, the following: The Durham VA Health Care system requires an automated immunoassay analyzer to perform a broad range of testing including Total Syphilis with RPR and Titer, 5th Generation HIV Ag/Ab, ANA Screen to include 13 analytes (dsDNA, Chromatin, Ribosomal P, SS-A 60, SS-A 52, SS-B, Sm, SmRNP, RNP A, RMP 68, Scl-70, Jo-1 and Centromere B), ToRC IgG, ToRC IgM, MMRV and anti-CCP. The contractor shall provide the analyzer and all supplies to the Durham VA Medical Center per the Statement of Work. Additional test/reagents/instrumentation may be added as new technology becomes available on the market. 1. GENERAL REQUIREMENTS: 1.1. The vendor(s) shall furnish all clinical laboratory supplies, materials, equipment, and services necessary for the performance of the work as described herein to the Durham VA Health Care System. 1.2. A list of the estimated yearly estimated quantities will be provided under this agreement. The quantity as listed is an estimate based upon prior history of the actual volume and is intended to provide the potential contractor a basis for calculating their pricing. It is not a guaranteed minimum. We estimate the yearly volume of patient tests at 20,000. 1.3. The pricing shall be based on new equipment. Currently installed equipment will be considered. Must be less than 2 years old at the beginning of the agreement. 1.4. The analyzer shall streamline all aspects of testing, thereby enhancing operational efficiency, improving turnaround time, supporting improved patient outcomes, and improving the productivity of the using facility. 1.5. Vendors shall provide the participating facility with Food and Drug Administration (FDA) approved analyzer/equipment, reagents, controls, calibrators, and any consumable part necessary for analyzing/testing. Vendor shall list the consumable parts provided. 1.6 5th Generation HIV assay must simultaneously detect, differentiate, and report HIV Ag-Ab, HIV-1 p24 Antigen, HIV-1 Antibody (Groups M & O), and HIV-2 Antibody. 1.7. Total Syphilis and RPR assay required. Assay must perform treponemal/non-treponemal immunoassay testing supporting traditional and reverse syphilis screening algorithm. The Assay must support simultaneous testing of Syphilis total and RPR along with RPR titers. All respondents shall indicate/provide the following: A copy of its capabilities statement. Documentation showing you re a authorized distributors of BioRad Failure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs. Responses to this sources sought notice should include the following: name and address of company, business size (large or small): Please identify your companies socioeconomic categories-8(a), HUBZone, Services Disabled Veteran-Owned/Veteran-Owned Small Business, other small, small or large; provide a brief description of qualifications and any other pertinent information which demonstrates the ability to meet the above requirement. Subject line must reflect: BioPlex. All capability statements shall be submitted in writing no later than December 8th by 12PM to the attention of: Byron Brown, emailed to the address of Byron.Brown4@va.gov Please title the subject line for all responses as: BioPlex
- Web Link
-
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/a8e468fb07374a99b0eeedc3d798d1e0/view)
- Place of Performance
- Address: Durham VA Medical Center 508 Fulton St., Durham, NC, USA
- Country: USA
- Country: USA
- Record
- SN07658221-F 20251206/251204230040 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |