Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 01, 2026 SAM #8833
MODIFICATION

65 -- VPRO Max2 Low Temp Sterilizers

Notice Date
1/30/2026 6:22:12 AM
 
Notice Type
Solicitation
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25526Q0168
 
Response Due
2/10/2026 9:00:00 AM
 
Archive Date
02/25/2026
 
Point of Contact
Jon Lutmer, Phone: 4104463862
 
E-Mail Address
Jonathan.lutmer@va.gov
(Jonathan.lutmer@va.gov)
 
Small Business Set-Aside
NONE No Set aside used
 
Description
1. STATEMENT OF WORK The contractor shall furnish all requisite services, labor, travel, transportation, materials, shipping, parts, connections, and equipment for the provision and on-site installation of a minimum of three vaporized hydrogen peroxide Low Temperature Sterilizers. These units are to be located at 4801 Linwood Blvd, Kansas City MO 64128. These low temperature sterilizers are essential for the Sterile Processing Service (SPS) in reprocessing reusable medical devices (RMDs) employed in invasive procedures. needed to support Sterile Processing Service (SPS) for reprocessing reuseable medical devices (RMD) used in invasive procedures. Furthermore, these units are critical for supporting medical procedures and surgeries and surgeries conducted within the Operating Room, as well as in various ancillary clinics throughout the KCVA. The contractor shall additionally furnish training to clinical personnel prior to the utilization of the equipment. This training is to encompass all tours of duty for the sterile processing department and necessitate annual retraining on all associated on all associated equipment. Moreover, the contractor bears the responsibility for the removal and disposal of all debris and packaging material resulting from the installation of the VPRO MaX2 Low Temp Sterilizers. 2. SPECIFICATIONS � Three low temperature sterilizers shall have a minimum individual dimensions of Cabinet (DD): 33 x 40-15/16 x 72� (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x 38-5/16 x 72� (838 x 973 x 1829 mm). o Mounting single door, cabinet o System installation requires no plumbing, ventilation or air o supply � only a dedicated electrical connection is needed. A power cord is supplied for this connection o The facility space in which the vehicle can occupy is approx. 35� x 110�. � Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing heat- sensitive materials because temperatures within the load currently do not exceed 55�C (131�F) and sterilization occurs in a low-moisture environment. Heat tolerant devices and materials can also be indicated for vaporized hydrogen peroxide sterilization processes. FDA-cleared vaporized hydrogen peroxide sterilizers, either with or without plasma, are currently available in the United States. ? Per ANSI/AAMI ST58:2013 or subsequent, the sterilizer shall be installed and operated in an area with a ventilation system capable of at least 10 air exchanges per hour. ? VPRO MaX2 must support utility requirements: o Current 16 AMP o Minimum Circuit Breaker 20 AMPS o Use NEMA L15-20R Plug o Provide grouped or ganged circuit protection and disconnect for phase 3 power as required by NEC and local codes. o Individual power shutoffs near each machine for servicing. ? Shall integrate with the CensiTrac Instrument Tracking System.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/47f4b906478c432186acf7067ca18496/view)
 
Place of Performance
Address: Kansas City, MO 64128, USA
Zip Code: 64128
Country: USA
 
Record
SN07701787-F 20260201/260130230036 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.