SOURCES SOUGHT
46 -- WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS
- Notice Date
- 2/9/2026 7:00:41 AM
- Notice Type
- Sources Sought
- NAICS
- 333310
—
- Contracting Office
- 246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
- ZIP Code
- 23667
- Solicitation Number
- 36C24626Q0335
- Response Due
- 2/17/2026 7:00:00 AM
- Archive Date
- 03/19/2026
- Point of Contact
- John P Harmsen, Contract Specialist, Phone: 757-722-7961
- E-Mail Address
-
john.harmsen@va.gov
(john.harmsen@va.gov)
- Awardee
- null
- Description
- VAMC Hampton is looking for a Water Purification system with the following: - Salient Characteristics - Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities - MODEL MEDICA-R 200 - Make-up rate 15C 200 l/hr - Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1) - Organics (TOC) - typical 250 Softener or use very low RO recovery3 - Free chlorine: Cl2ppm 0.5 Cylinder of carbon sized correctly to obtain 0.5 Cylinder of carbon sized correctly to obtain 30 20 inch cartridge depth filter or use very low RO recovery (4) - Fouling index: FI 20 Back washable media filter with a minimum flow rate of 20 l/min - Iron/manganese: Fe/Mn ppm 0.05 20 inch cartridge depth filter (5) - >0.1 Back-washable Fe filter (6) - Organics: TOC ppm C 3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C) -- Flowrate: (requirement at 15°C) 20 l/min - Drain requirements: (gravity fall with air gap) 45 l/min - Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum - Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning, - 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required) - Must include Installation, Commissioning, Training - Electrical Requirements Mains Input: 115V, 60Hz - System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA - Electrical protection rating 20 amps Noise level during recirculation <70dBA - ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters. - -The floor drain must be a minimum of 3"" and meet all applicable building codes and system requirements - -Actual Unit measurement 32"" Wide x35""Deep x72""High
- Web Link
-
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/fd16752ac47f4f01b09800caf95aec3c/view)
- Record
- SN07710318-F 20260211/260209230043 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |