Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 20, 2026 SAM #8852
SOLICITATION NOTICE

Y -- Replace Fire Hydrant at USCG Air Station Clearwater

Notice Date
2/18/2026 10:17:19 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238290 — Other Building Equipment Contractors
 
Contracting Office
BASE MIAMI(00028) MIAMI FL 33132 USA
 
ZIP Code
33132
 
Solicitation Number
20150PR260000047
 
Response Due
3/13/2026 11:00:00 AM
 
Archive Date
03/28/2026
 
Point of Contact
CWO Jose Calderon, Phone: 727-423-7586 CELL PHONE, DC1 Richard Rendon, Phone: 727-535-1437 ext 1550
 
E-Mail Address
jose.a.calderon@uscg.mil, Richard.L.Rendon@uscg.mil
(jose.a.calderon@uscg.mil, Richard.L.Rendon@uscg.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
COMBINED SYNOPSIS/SOLICITATION CONSTRUCTION Replace Fire Hydrant at USCG Air Station Clearwater 1. General Information Solicitation Number: 20150PR260000047 Date Posted: 02/18/2026 Response Due Date: Friday March 13, 2026, at 2:00PM EST NAICS Code: 238290 Other Building Equipment Contractors Set-Aside: Total Small Business Set a Side Contracting Office: USCG PROCUREMENT & CONTRACTINNG 12100 SW 152ND ST MIAMI, FL 33177 Point of Contact: Mehdi Bouayad Email: Mehdi.Bouayad@uscg.mil 571-607-8108 2. Description of Work This is a combined synopsis/solicitation for construction services prepared in accordance with FAR Part 36 and FAR Part 13. The U.S. Government intends to award a firm-fixed-price contract based on the lowest price technically acceptable (LPTA) or best value tradeoff method. Scope of Work: General: United States Coast Guard Air Station Clearwater is accepting proposals for qualified individuals or firms to replace one fire hydrant at Air Station Clearwater. Prior to submitting a quote, it is mandatory to examine the scope of work and it�s highly recommended to visit the facility to take field measurements, evaluations, etc. and become familiar with existing conditions under which The work will be performed. After the award of contract, a pre-conference will be held prior to starting work at Coast Guard Air Station Clearwater. Location: U.S. Coast Guard Air Station Clearwater 15100 Rescue Way Clearwater, Florida 33762 Examination of Site: It is HIGHLY ENCOURAGED that bidders carefully inspect the workplace and verify all work necessary to complete job. Prospective bidders arrange for a tour of the job site by calling the point of contact, CWO Joe Calderon at 727-423-7586 or via email at Jose.A.Calderon@uscg.mil or DC1 Richard Rendon at (727) 535-1437 x1550 or by email at Richard.L.Rendon@uscg.mil, at least 3 working days in advance. 1. Continuity of Facilities Operation: Schedule work to minimize interference with the facility operations and during the normal operating hours of 7:00 am to 3:00 pm Monday thru Friday, excluding federal holidays. Work may be conducted during other hours if approved in advance by coordinating with the facility Point of Contacts (POC) listed below. 2. Notification of Start and Completion of Work: The Contractor shall provide a simple and general schedule of work. For example, �Begin work at ____ on _______. Work is expected to last __ days and be complete on _______.� 3. Coast Guard Points of Contact: The Contractor shall coordinate with the following personnel to arrange access the facility. POC�s are listed in order of preference. Name Email / notes Phone Number CWO Joe Calderon Jose.A.Calderon@uscg.mil 727-423-7586 (cell phone) MKC Mike Hemmingway Jonathan.M.Hemmingway@uscg.mil 727-535-1437 x1573 DC1 Rich Rendon Richard.L.Rendon@uscg.mil 727-535-1437 x1550 Page 3 of 13 4. Recycling and Disposal of Refuse: Minor refuse and waste materials resulting from operations may be disposed of in Air Station Clearwater dumpsters. All disposals shall be done in accordance with federal, state, and local laws and regulations. No Hazardous Waste or bulk waste may be disposed of in Air Station Clearwater dumpsters. 5. Safety: During the execution of this contract, the Contractor shall conform to the rules and regulations as set forth by OSHA State and Federal regulations. Immediate notification to the Contracting Officer�s Representative of lost time due to accidents is required. Provide two copies of Workman�s compensation accident reports by noon of the day following the accident. The Coast Guard reserves the right to bar any workers or supervisors from the premises should they be documented as violating set safety standards and regulations. 6. Inspection: The Contracting Officer�s Representative has the right to reject defective workmanship or materials or work not performed as per the contract specifications. 7. Operations and Storage: The Coast Guard has no responsibility for receipt, storage, or protection of contractor�s materials. The Coast Guard will not accept shipments, and no materials may be stored on site by the contractor. The contractor is responsible for the protection of existing structures and utilities and vegetation. Any damage shall be repaired at the contractor�s expense. 8. Utilities: Contractor is authorized to use Air Station Clearwater power and water while conducting the work efforts outlined in this document. Any other use of power is not authorized. The unit POC�s listed above will designate available utility connection points if necessary. 9. General Regulations while onboard Coast Guard Air Station Clearwater: 1. Daily colors and the raising/lowering of the American flag will take place every morning at 0800 and every evening at sunset. All personnel on Base will face the main flagpole & maintain silence and all vehicles & equipment will halt during these brief events. 2. Contractors are welcome to eat breakfast & lunch at Base in the base galley at published meal rates. Breakfast is served from 0600-0730 daily & lunch will be served from 1100- 1230 daily in the galley. All personnel desiring meal service shall be in clean, non-soiled clothing. The Coast guard reserves the right to refuse service to anyone it deems dirty. 3. Contractors are welcome to utilize the Base�s Exchange store; however, contracted personnel are prohibited from purchasing any uniform, alcohol or tobacco products in it. 4. Traffic Regulations: a. 10 mph speed limit b. No use of cell phones is permitted while driving vehicles or operating heavy machinery. Page 4 of 13 c. All personnel shall obey all marked traffic signals including stop signs & stoplights. 5. Notice shall be given to the Coast Guard�s representative 1 week in advance of any planned outages, including any pool closure and expected duration. 6. Contractors are welcome to utilize the restrooms in the area they are currently working in providing they are clean and do not track mud, dirt or any other debris into the restrooms. 7. No personnel other than the Contracting Officer has the authority to alter the terms of any contract or to issue any change orders. Accordingly, the contractor shall not complete any work that would incur additional costs to the government without written approval from the Contracting Officer. 10. SECURITY REQUIREMENTS: 1. The contractor shall provide a consolidated list of all contractor personnel who will be working on Air Station Clearwater Facilities at least 1 week prior to work. This is for routine/ standard background checks of all personnel entering the base. Information required is full name, date of birth, and last 4 digits only of Social Security Number. 2. Only American citizens and permanent resident aliens are allowed onboard Air Station Clearwater Facilities. Absolutely no foreign nationals are permitted on the premises. Appropriate identification shall be provided at the front gate to attain base entry. 3. All contractor vehicles, equipment and gear onboard Coast Guard properties are subject to search, at all times. Additionally, at all times due to security and operational needs, the contractor is subject to orders to evacuate the property at any time. 4. Absolutely no firearms or weapons of any kind are allowed onboard Air Station Clearwater. 5. The contractor and subcontractor personnel shall wear company identification and always carry photo identification on their person. Personnel shall not stray from the immediate area of work nor direct avenues of ingress and egress unless authorized in advance. 11. SCOPE OF WORK: Contractor shall provide all labor, trades, equipment, components, materials, tools, and supervision necessary to replace non-functioning fire hydrant and installation of a new American Darling 5-1/4� Fire Hydrant. All work shall be completed in accordance with industry and manufacturing standards. Objectives: ? Replace the existing non-functional fire hydrant with new American Darling Model 5-1/4� Fire Hydrant. ? Ensure compatibility with the base�s water supply and fire protection requirements. ? Restore the site to original condition. Page 5 of 13 Contractor Responsibilities: ? Contractors shall provide all labor, materials, equipment, permits, supervision and quality control. ? *Note* USCG is furnishing Fire Hydrant, Traffic flange, Gate valve, and associated gaskets. (See pictures below) ? The contractor shall be responsible for repairing, at no cost to the government, any damage caused during the installation of the fire hydrant. Work Requirements: Pre-Construction ? Conduct site visit and utility verification. ? Coordinate with USCG Facility Engineering for access and safety requirements. ? Perform utility locates. ? Submit product data for approval. ? Identify potential interferences and job hazards Demolition and Removal ? Identify Main Water Supply control and isolation valves (see pictures below) ? Isolate and depressurize the water main. ? Excavate around the hydrant assembly. ? Remove hydrant and associated parts. ? Dispose of materials as per regulations. Hydrant Installation ? Install a new American Darling fire hydrant, including Traffic flange, 5-1/4� and any associated parted needs. ? Gravel bed if required. ? Proper burial depth. ? Hydrant orientation per local and city codes. Testing and Operation ? Flush service line ? Pressure test per AWWA C600. ? Flow test of hydrant to verify leak free operation, proper drainage, adequate flow and residual pressure. ? Demonstrate operation to USCG Facilities. Site Restoration ? Backfill excavation ? Restore pavement, concrete, and landscaping disturbed during work to original condition or better. ? Apply corrosion protection to exposed metal hardware as required. ? Paint hydrant red. Deliverables ? Pressure and flow test results ? Drawings (If applicable) Page 6 of 13 Contractor shall be responsible for the removal of all trash and debris from project area off site upon completion. All work must be approved by the Contracting Officer�s Representative. Warranty: The Contractor warrants that all workmanship shall be free from defects for a period of one years from the date of substantial completion. 12. ACCEPTANCE OF WORK: When the contractor has completed all work, they shall notify the Coast Guard (COR) for a final inspection with least a 24-hour notice. If there are any project discrepancies noted, they shall be corrected within 5 business days of discovery. The work will be accepted as complete upon verified correction of any/ all noted discrepancies. After work acceptance, the contractor shall submit final invoice to the Coast Guard as directed by the COR. Place of Performance: USCG Air Station Clearwater 15100 Rescue Way Clearwater, FL 33762 Magnitude of Construction: Not to exceed $13K 3. Submission Details Proposals Due By: Friday Mar 13, 2026/2pm EST Submission Method: [Email Mehdi.Bouayad@uscg.mil or Mailed Bids] Technical Proposal (demonstrating capability and experience). Price Proposal (detailed cost breakdown). Past Performance References will be reviewed 4. Site Visit Highly Recommended but not mandatory **************** Wednesday Feb 25, 2026 at 10:00AM EST***************** Site Visit Coordinator is CWO Joe Calderon Email: Jose.A.Calderon@uscg.mil Phone: 727-423-7586 5. Evaluation Criteria Award will be made based on [Lowest Price Technically Acceptable (LPTA) / Best Value] criteria. Proposals will be evaluated on: 1. Technical Acceptability � Demonstrated experience in similar projects. 2. Past Performance � Positive references from previous construction work. 3. Price Reasonableness � Competitive pricing aligned with market rates. 6. Contract Terms and Conditions This procurement is subject to the following: Davis-Bacon Act Compliance: Wage Rates FL20260222 Revised on 01/02/2026 FAR Clauses 52.236-2 (Differing Site Conditions), 52.236-3 (Site Investigation), 52.236-5 (Material and Workmanship), 52.236-7 (Permits and Responsibilities). Other federal, state, and local regulations governing construction contracts. 7. Inquiries All questions regarding this solicitation must be submitted in writing to CWO Joe Calderon no later than Tuesday Mar 10, 2026. Issued By: Contracting Officer Mr. Mehdi Bouayad United States Coast Guard 8. Additional Clauses and Provisions 8.1 Safety and Health Requirements The contractor shall comply with: Occupational Safety and Health Administration (OSHA) Standards (29 CFR 1926) for construction safety. U.S. Army Corps of Engineers Safety Manual EM 385-1-1, if applicable. Submission of a Site-Specific Safety Plan (SSSP) within [X] days after award. Implementation of Personal Protective Equipment (PPE) and safety measures for workers on-site. 8.2 Environmental and Sustainability Requirements The contractor shall comply with National Environmental Policy Act (NEPA) and all EPA regulations. Use of environmentally preferable products and materials in accordance with FAR 23.1 (Sustainable Acquisition Policy). Proper disposal and handling of hazardous materials per Resource Conservation and Recovery Act (RCRA). Stormwater Pollution Prevention Plan (SWPPP) implementation (if applicable). 8.3 Compliance with the Davis-Bacon Act For contracts over $2,000, the contractor shall comply with the Davis-Bacon Act (40 U.S.C. 3141�3148): Submit certified payroll reports weekly. Pay laborers and mechanics at least the prevailing wage rates specified in the wage determination. 8.4 Delays and Liquidated Damages If the contractor fails to complete work by the agreed deadline, the Government may impose liquidated damages of $[X] per calendar day of delay. Delays due to unforeseen conditions (e.g., weather, force majeure) must be reported within 24 hours and documented. 8.5 Subcontracting Limitations In accordance with FAR 52.219-14, at least 15% of the contract value must be performed by the prime contractor (for general construction). Subcontractors must be pre-approved, and the prime contractor remains liable for their compliance. 8.6 Material and Workmanship Standards All materials shall conform to industry standards (ASTM, ANSI, etc.) and be subject to Government inspection. The Government reserves the right to reject defective work and require rework at contractor�s expense. 8.7 Bonding and Insurance Requirements For contracts over $150,000, performance and payment bonds are required per FAR 28.102-1. Contractors shall maintain liability insurance in the following amounts: General Liability: $1,000,000 per occurrence. Workers� Compensation: As required by state law. Automobile Liability: $500,000 per accident. 8.8 Inspection and Acceptance Work will be inspected by the Contracting Officer�s Representative (COR). The Government reserves the right to reject non-conforming work and withhold payment until deficiencies are corrected. 8.9 Buy American Act Compliance Materials must comply with the Buy American Act (FAR 52.225-9) unless an exemption is approved. 8.10 Dispute Resolution and Claims Disputes shall be handled per FAR 52.233-1 (Disputes Clause). The contractor must attempt to resolve disputes through negotiation before escalating to formal claims.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/c298278d31a046369476c88d59d132f4/view)
 
Place of Performance
Address: FL 33762, USA
Zip Code: 33762
Country: USA
 
Record
SN07719168-F 20260220/260218230038 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.