COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 10,1995 PSA#1281COMMANDER, ATTN CTQ, MARCORSYSCOM 2033 BARNETT AVENUE SUITE 315
QUANTICO, VA 22134-5010 46 -- TEAM WATER PURIFICATION FILTER SOL M67854-95-R-2160 POC Jeff
Campbell, Code CTQ-3JC, (703) 640-5822, ext.234. The Marine Corps
Systems Command intends to award a sole source contract to Mountain
Safety Research, for the procurement of Non-Developmental Item (NDI)
Team Water Purification Filter (TWPF). Mountain Safety Research, is a
small business concern and the Standard Industrial Classification (SIC)
code is 3589 and size is 500 employees. The (TWPF) shall be a raw fresh
water treatment unit for field use by military servicemen. The TWPF
shall purify contaminated fresh water from any available source
normally found in geographical locations in which the United States can
expect to employ military forces. The TWPF shall protect personnel from
cyst- forming protozoa and bacteria, making the water safe for human
consumption, while reducing the quantity of turbidity that is common in
raw water sources. It is intended that the TWPF shall, at a minimum,
have the capability to be used as a pretreatment to the use of the
standard military water purification tablet, NSN 6850-00-985-7166, in
order to protect the intended user from viruses as well as the
previously mentioned microbiological hazards. Together, TWPF and the
water purification tablet shall provide complete disinfection of all
water-borne pathogenic microorganisms so that personnel can consume the
water without becoming ill. Technology capable of combining the
filtration process and complete disinfection process into one
mechanical procedure is acceptable. Principal (Required)
Characteristics: (a) The TWPF shall remove or destroy a minimum of
99.9% (3 log reduction) of cyst-forming protozans (Cryptosporidium
parvum). ( b) The TWPF shall remove or destroy a minimum of 99.9999% (6
log reduction) of bacteria (Klebsiella terrigena). (c) The TWPF shall
reduce turbidity to 0.5 Nephelometric Turbidity Units (NTU) or less in
the effluent produced by the purification device for 95% of the
measurements taken for a total production of 84 gallons of ''purified''
water when the source water has a turbidity of 60 NTUs. (d) The TWPF
shall be capable of supplying a minimum of 84 gallons of purified water
(0.5 NTUs or less) before replacement of filter element(s) is required
when filtering source water with turbidity level of 60 NTUs. (e) The
TWPF shall be compatible with the standard military issue canteen (NSN
8465-01-115-0026) and shall be capable of easily transferring product
water to a canteen without spillage. (f) The water purifier shall
provide the capability of veryifing to the operator (ie. a visual or
physical signal) that the purification process is meeting established
water quality and that the filter media has not reached the end of its
operating life. The device shall have a secondary filtering system
capable of having two filtration media in series so that the second
filter shall provide backup in the event that the primary filter fails.
The second filter media in the series shall have an absolute micron
rating of 0.2 microns to be considered a ''fail safe'' filter. The
device shall also have a positive physical measuring device (ie. a
''caliper'' to measure the remaining width/diameter of the filter
media). Any such device shall be easily used in remote field locations
by the operator without creating noise or requiring additional
equipment not included with the water purification unit. (g) Over-
pressurization of the water purifier/filter media shall not cause the
unit to fail (ie. permit micro-biological hazards or turbidity above
0.5 NTUs to be present in the product water) without a positive
indication to the operator. Therefore, the use of a pressure relief
valve to reduce flow through the filter media is highly recommended.
(h) The TWPF shall not exceed 2 pounds, with 1.5 pounds desired. These
weights include the operational filter, case and all peripherals
required for operation/cleaning. (i) The size of the TWPF shall not
exceed the following limitations: for a Non-cylindrical Unit (ie. a
rectangular or any shape other than cylindrical) device length of 12
inches, device width of 4 inches, and device height of 4 inches. For a
cylindrical unit, the following dimensions shall not be exceeded:
device length 12 inches and device diameter 4 inches. (j) It is desired
that the TWPF remove or destroy a minimum of 99.99% (4 log reduction)
of virus (Poliovirus type 1/Rotavirus SA11 as a mixed viral culture).
The TWPF shall accomplish this by processing the source water only one
time to remove or destroy a minimum of 99.99% (4 log reduction) of
virus (Poliovirus type 1/Rotavirus SA11 as a mixed viral culture)
without the addition of standard military issue iodine tablet. Multiple
''passes'' through the device shall not be acceptable. Vendors who have
the capability to provide the requirements for this contract should
submit in writing technical qualifications along with independent
excerpts from test reports to verify that their candidate system meets
all of the above stated requirements not later than 28 Feb 95. Only
fully qualified vendors with a ready production capability should
respond. This information should be mailed to: Commander, ATTN CTQ 3JC,
MARCORSYSCOM, 2033 Barnett Avenue, Suite 315, Quantico VA 22134-5010.
Proprietary information shall be protected and should be clearly
identified. See Numbered Note 22. (0039) Loren Data Corp. http://www.ld.com (SYN# 0296 19950209\46-0001.SOL)
46 - Water Purification and Sewage Treatment Equipment Index Page
|
|