COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 23,1995 PSA#1289U. S. Army Corps of Engineers, Omaha District, 215 North 17th Street,
Omaha, NE 68102-4978 C -- IDT CONTRACT FOR MISCELLANEOUS ENGINEERING SERVICES FOR FORT
CARSON, COLORADO SOL DACA45-95-R-0039 POC For further information,
Contact Marie Carlin at: (402) 221-4915. CONTRACT INFORMATION: An
Indefinite Delivery Type contract will be awarded for a period of one
year and may include an option for one additional one year extension.
Each Delivery Order issued under this contract will not exceed $150,000
with cumulative amount of contract not to exceed $1,500,000 ($750,000
per year). Delivery Orders will be issued from time to time as the need
arises during the contract period. Types of services required will
include Site investigations, studies, reports, concept design, final
design and construction phase services. Completion date is one year
after date of award with an anticipated start date of September 1995.
If a large business is selected for this project, it must comply with
FAR 52.219-9 regarding the requirement for a subcontracting plan on
that part of the work it intends to contract. This plan is not required
with this submittal. The subcontracting goals for this contract are
that a minimum of 28% of the contractor's intended subcontract amount
be placed with small businesses (SB), including small disadvantaged
businesses (SDB), and 8% be placed with SDB. PROJECT INFORMATION:
Delivery orders under this contract may include a wide variety of
projects including design for new construction, renovation of existing
facilities, maintenance and repair. Types of facilities include
medical, administrative, housing and community, maintenance and
production, operations and training, and utilities and grounds
improvements. SELECTION CRITERIA: See Note 24 for general selection
process. Criteria for selection, in order of importance, are: (a)
Recent specialized experience and technical competence of the firm
(including consultants) in: (1) Providing services similar to those
described above on a wide variety of facility types with an emphasis on
renovation design of administrative type facilities. (2) Compliance
with EAP, OSHA, and applicable state regulations relating to asbestos
and lead paint sampling, testing and removal. (3) Producing quality
designs as evidenced by the firm's quality control procedures. (4)
Effective coordination and management of the project team, including
consultants. (5) Producing Computer Aided Drafting and Design (CADD)
drawings fully compatible with Auto CADD Version 12 or Intergraph CADD
Version 4.0.3. (b) Professional qualifications and specialized
experience in providing services similar to those listed above of the
proposed team members (including consultants) in the following
disciplines: civil, mechanical, electrical, structural,
environmental/sanitary, fire protection, cathodic protection, and
geotechnical engineering, architecture, estimating, industrial hygiene,
and landscape architecture. (c) Capacity to accomplish the work in the
required time, including the ability to complete more than one work
order at a time. (d) Past performance as described in Note 24. (e)
Location in the general geographic area of Fort Carson, Colorado. (f)
Extent of participation of SB, SDB, historically black colleges and
universities, and minority institutions in the proposed contract team,
measured as a percentage of the estimated effort. (g) Volume of DOD
contract awards in the last 12 months as described in Note 24.
SUBMITTAL REQUIREMENTS: Solicitation packages are not provided for A-E
contracts. This is not a request for proposal. Firms desiring
consideration shall submit two copies of a combined SF 255 and separate
SFs 254 for prime and each consultant. To be considered, submittals
must be sent to the U.S. Army Corps of Engineers and addressed as
follows: Omaha District, A-E Contracts Support Section, ATTN: John M.
Miller, CEMRO-ED-MG, 215 N. 17th Street, Omaha, NE 68102-4978.
Submittals must be received no later than close of business on the 30th
day after the date of publication of this announcement. If the 30th day
is a Saturday or Sunday or a federal holiday, the deadline will be the
close of business on the next business day. In block 10 of the SF 255,
provide the following: (a) Design Management Plan (DMP). The DMP should
be brief and include an explanation of the firm's management approach,
management of subcontractors (if applicable), specific quality control
procedures used and an organizational chart showing the inter-
relationship of management and various team components (including
subcontractors). (b) The firm's present workload and the availability
of the project team (including consultants) for the specified contract
performance period. In block 3 of SF 255 provide the submitting firm's
number (six or seven digits) assigned by the North Pacific Division,
U.S. Army Corps of Engineers, for the Architect-Engineer Contract
Administration Support System (ACASS) and the firm number for any
consultants in block 6 of the SF 255. If unknown, so state. To receive
information to obtain an ACASS number, call (503) 326-3459. Personal
visits for this solicitation to the Omaha District office or the Ft.
Carson offices will not be scheduled. Administrative and procedural
questions shall be directed to John M. Miller at (402) 221-4176. See
Numbered Note(s): 24. (0052) Loren Data Corp. http://www.ld.com (SYN# 0023 19950222\C-0002.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|