U.S. Army Engineer District, Savannah, Corps of Engineers, ATTN: CESAS-EN-EA, P.O. Box 889, Savannah, Georgia 31402-0889 or 100 W. Oglethorpe, Savannah, GA 31401-3640

C -- REPLACE FAMILY HOUSING, PHASE III, ROBINS AFB, GA POC CHARLES BOWDEN AT 912/652-5689. 1. CONTRACT INFORMATION: Nature of Work: A-E services are required for preparation of Area Development Plan (ADP) for proposed Air Force Military Family Housing at Robins AFB, GA. ADP to include layouts for utilities and roads. Design options may be exercised to complete final design for construction documents for 60 units with a possible increase to 125 units. This will be a firm fixed price contract. The contract is anticipated to be awarded in April 1995 and completed in May 1997. A-E services may include site investigations, planning engineering studies, concept design, final design (option). This announcement is open to all businesses regardless of size. ** 2. PROJECT INFORMATION: Replacement of these units is required to provide adequate quarters for junior enlisted military members and their families assigned to this installation. All units will meet ''whole house'' standards and are programmed in accordance with Phase A of the Housing Community Plan. Replacement housing will be provide a safe, comfortable, appealing living environment comparable to the off-base civilian community. This is the third of multiple phases to provide adequate housing for base personnel. Of the 460 housing units to be replaced, 173 are completed or included in prior programs, and 227 will follow in subsequent phases. Carports are needed to protect occupant's vehicles from exposure to the elements. Driveways and off-street access will eliminate unsafe on-street parking. Playgrounds are required to provide safe recreational areas for base dependents. Signs are needed to foster neighborhood pride and identification. The estimated construction cost of each project is $1,000,000.00 to $10,000,000.00. The estimates for this project shall be prepared using the latest Version of MCACES Gold Software. The software and User's Manual will be provided to the successful A-E. The drawings will be prepared using graphics created via Intergraph Microstation 32 or Micro/Station PC (4.0) and/or AutoCADD Version 11. All drawing files delivered to the District that have been created using AutoCADD Version 11 must be translated to .dgn files. The Contractor shall possess the software to enable the full translation of drawing files from .dwg and vice versa. Before final selection the preselection A-E's may be required to demonstrate the above compatiblity by reproducing a Government supplied standard drawing and translating it to the Intergraph format above. The method of translation must be thoroughly described and documented in Block 10 if the A-E does not have an Intergraph CADD System. The A-E selected will be required to submit a Design Quality Assurance Plan concurrently with their fee proposal. Information on what is to be contained in this plan will be furnished upon notification of selection. Firms responding to this announcement are requested not to transmit this plan with their SF 255. ** 3. SELECTION CRITERIA: See Note 24 for the general process. The selection criteria in descending order of importance are: ** a. Specialized experience in the type of work described in Project Information. ** b. Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. ** c. Capacity to accomplish the design in the required time and dedicate at least 2 personnel in the following disciplines: architectural, and civil engineering and dedicate at least 1 person in electrical engineering, structural engineering, mechanical engineering, environmental engineering, industrial hygienist (asbestos) and topographic surveying. The design team must include a Registered Engineer or Registered Architect who is a full ''member'' in good standing of the Society of Fire Protection Engineers (SFPE) or an individual who is a registered Fire Protection Engineer and whose principle duties are Fire Protection Engineering. ** d. Professional qualifications of key management and professional staff members. ** e. Extent of participation of SB, SDB, WOB, historically black colleges and university and minority institutions in the proposed contract team, measured as a percentage of the estimated effort. ** f. Location of the firm in the general geographic area of the project. ** g. Volume of DoD contract awards in the last 12 months as described in Note 24. ** 4. SUBMITTAL REQUIREMENTS: Firms desiring consideration must submit ONE (1) copy of SF 255 (revised 11/92) for prime and ONE (1) copy of SF 254 (revised 11/92) for prime and each consultant to the above address by 31 March 1995 to be considered for selection. DEPTH of PRIME and SUBCONTRACTOR personnel in EACH discipline must be shown in Block 4 of SF 255 and SF 254 to clearly identify the number of personnel in each firm and discipline. COVER letters and extraneous materials are NOT desired and WILL NOT be considered. ** PHONE calls are DISCOURAGED unless absolutely necessary. Personal visits for the PURPOSE of DISCUSSING this announcement will not be scheduled. THIS IS NOT A REQUEST FOR A PROPOSAL. (0058)

Loren Data Corp. http://www.ld.com (SYN# 0041 19950228\C-0015.SOL)


C - Architect and Engineering Services - Construction Index Page