COMMERCE BUSINESS DAILY ISSUE OF MARCH 13,1995 PSA#130155 Contracting Squadron/LGCS 106 Peacekeeper Dr STE 2N3 Offutt AFB NE
68113-4009 65 -- 2 EACH, STERIS SYSTEM I STERLIZER SOL F25600-95-R0014 DUE 033095
POC SSgt Mark W. Hagood (402) 294-9606. Notice of intent to negotiate
on a sole source basis with the Steris Corp for the purchase of the
following items: Steris System I Sterilizer. The Steris system employs
a single-use concentrate of 35% peracetic acid and a unique
anti-corrosive chemical formulation that is safe to dispose of,
following use, in a regular sanitary drain. The unit shall be
environmentally safe. The system shall be safe for heat-sensitive
immersible instruments. The rapid low temperature, liquid chemical
Steris process shall be accomplished within 20-30 minutes. The system
shall contain an electronic system to monitor and maintain the
parameters necessary to assure sterile processing. A hard copy printout
at the end of each cycle shall be provided for Quality Assurance
records. Sterilization can also be monitored by commercially prepared
microbial biological indicators. ELECTRICAL REQUIREMENTS: The Steris
System I processor includes a power cord and connector. To prevent
overload and loss of any electrical power to critical equipment, a 20
amp, 120 dedicated circuit, terminated in a 20 amp hospital grade GFCI
double receptacle is required. WATER REQUIREMENTS: The Steris System
I processor requires a potable water source with the following
specifications; Pressure = 40-50 PSI / Flow rate = 4 GPM at 40 PSI /
Temperature =43 - 48 degrees C. / Connection = 3/4'' male hose
connection / Quality = Potable/tap water / Supply line = 1/2'' inch
I.D. minimum / Water usage = approzimately 13.3 Gal per sterilization
cycle. DRAIN REQUIREMENTS: The outlet of the drain hose shall be above
the drain water level or drain trap water leve by six inches. The
drain shall be non-backpressuring, and if a connection is used, it
shall be non-restrictive. The preferred drain type is a 1 1/4'' I.D.
(minimum) stand pipe. It is the government's belief that Steris Corp is
the only manufacturer capable of meeting the minimum needs of the
government. Interested parties may identify their interest and
capabilities to respond to this requirement by submitting technical and
pricing data within 15 calendar days from the publication date of this
sysnopsis. Information received as a result of this notice on intent
will be considered solely for the purpose of determining whether to
conduct a competitive procurement. A determination by the government
not to open the requirement for competition based upon responses to the
notice is solely within the discretion of the government. The
government will not pay for information received. All responses must be
in writing. FAX number (402) 294-1503, telephone request will not be
honored. All responses must include the 4-digit extension to the zip
code. If no acceptable responses are received from interested parties,
the government will begin negotiations with Steris Corp for the
pruchase of the item listed above. The solicitation will be issued on
or about 03 Apr 1995. (0068) Loren Data Corp. http://www.ld.com (SYN# 0371 19950310\65-0001.SOL)
65 - Medical, Dental and Veterinary Equipment and Supplies Index Page
|
|