COMMERCE BUSINESS DAILY ISSUE OF MARCH 15,1995 PSA#1303US ARMY CORPS OF ENGINEERS, NEW YORK DISTRICT 26 Federal Plaza, New
York, New York, 10278-0090, Attn: CENAN-EN-MR C -- FY96 PN#961014 ECIP REPAIR HOT WATER MAINS AT MCGUIRE AFB
WRIGHTSTOWN, NJ SOL CBAEEN-5346-0010 POC W. Cunningham, 212-264-9123.
This amends the previous announcement for this action previously
advertised inadvertantly in Section ''Y'' instead of Section ''C'' in
the CBD of 27 January 95. The text of this announcement remains the
same as the orignial 27 Jan 95 advertisememt. Location: McGuire AFB,
NJ. Scope of Services Required: The completion and development of field
investigations, surveys, detailed construction cost estimates, design
analyses, plans and specifications, and construction services. The
scope of work for the proposed project involves the preparation of
plans, specifications and cost estimates for the replacement of
existing High Temperature Hot Water (HTHW) lines with a shallow trench
arrangement. Principal features of the work include, but are not
limited to the production of project documents to replace HTHW lines
that range from 1 1/2'' to 8'' in diameter. Both supply and return
lines as well as air controlled lines shall include all the
requirements of and be manufactured by a supplier that is pre-approved
for furnishing certified Class A systems as approved by the
Tri-Service Committee Reconstruction/repair of 26 manholes along with
cathodic protection is required. Performance of environmnetal
investigation/testing of insulated pipe casing material will be
performed by the selected A/E if required. Estimated Construction Cost
Range: $1,000,000 to 5,000,000. Technical capability required but not
limited to: Mechanical, Electrical, Environmental, Structural, Civil,
Cost Estimating, Certified Asbestos Inspector. Responding firms should
indicate their ability to produce all required work in digitized
drawings on Autocad, their capability to access an electrionic bulletin
board and Automated Review Management System (ARMS) via modem, and the
capability of preparing construction estimates in M-CACES (Corps of
Engineers Cost Estimating Software) Special qualifications: The
selected firm should have specialized experience in the design and
rehabilitation of Underground High Temperature Hot Water Distribution
Systems (UDHS) for a Class A applications. Demonstrated experience in
Cathodic protection systems and Asbestos investigation testing and
abatement plans/procedures will also be considered. Familiarity with
DOD requirements, State of New Jersey and local requlations is
preferred. Familiarity with NJDEPE and Pineland Commission requirements
along with experience in the production of soil erosion control plans
are desirable. Maximim in house capability is preferred since this will
be a fast track project. Firms not having full in house capability must
demonstrate how they will manage consultants through a management plan
to insure quality control and ability to coordinate all design
disciplines. The selected firm should be familiar with U.S. Army Corps
of Engineers and U.S. Air Force design guidance and current
environmentsal law and regulations. Evaluation factors (in descending
order of importance): 1) Professional qualifications necessary for
satisfactory performance of required services; 2) Specialized
experience of the firm in the type of work required; 3) Capacity of the
firm to accomplish the work in the required time, reflecting
qualifications of key personnel; 4) Past industry in terms of cost
control, quality of work and compliance with performance schedules; 5)
Geographic location and k owledge of the locality of the project,
provided that application of this criterion leaves an appropriate
number of qualified firms, given the nature and the size of the
project; and 6) The volume of work previously awarded to the firm by
the Department of Defense, with the object of effecting an equitable
distribution among qualified A/E firms, including small and small
disadvantaged business firms, and firms that have not had prior
Department of Defense contracts. Estimated Design Start Date: April
1995. Estimated Design Completion date: August 1995. Small and
disadvantaged firms are encouraged to participate as prime contractors
or as members of joint ventures with other small business, and all
interested contractors are reminded that the sucessful contractor will
be expected to place subcontractors to the maximum practicable extent
with small and disadvantaged firms in accordance with Public Law
95-507. A/E firms which meet requirements described in this
announcement and desiring to be considered for selection are invited to
submit a SF 255. A/E and related services questionaire for specific
projects to US Army Corps of Engineers, 26 Federal Plaza, New York
10278-0090. ATTN: W. Cunninnngham (Rm 2143). Ms Cunningham can also
reached at (212) 264-9123. Interested A/E firms having the capabilities
to perform this work must submit their SF 255 (and SF 254 for the prime
and all consultants) to the above address no later than the close of
business on the 30th day after the date of this announcement. If the
30th day is a Saturday, Sunday, or Federal Holiday, the deadline is the
close of business of the next business day. Solicitation packages are
not provided for A/E contracts. This is not a request for proposal.
Firms not having a current SF 254 already on the file with this office,
and responding to this announcement should submit a copy of the SF 254
along with the SF 255. Personal visits for the purpose of discussing
the project are discouraged. Firms will indicate on block 10, page 11
of their SF 255's the total number of Department of Defense A/E Awards
(basics and delivery orders) and the total value of those awards
within the last 12 months prior to the date of this announcement. Firms
that do not comply with this requirement will be considered
non-responnsive. Firms should indicate whether their firm is listed in
the ACASS System in Oregon; if yes, please indicate your ACASS Number
in item 1 of SF 255. If not, submit two (2) copies of SF 254 on
initial response to our CBD. (0072) Loren Data Corp. http://www.ld.com (SYN# 0007 19950314\C-0001.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|