Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MARCH 24,1995 PSA#1310

Anniston Army Depot, Directorate of Contracting, Anniston AL 36201-4199

Z -- CHROME LINE VENTILATION REPAIR SOL DAAC01-95-R-0015 DUE 051695 POC Contract Specialist, Norma H. Gunnels, (205)235-4192, Contracting Officer, Kathy C. Harvey, (205)235-7558 Work consists of furnishing all plant, labor, materials, and equipment, and performing all work in strict accordance with specifications, schedules, and Drawing No. FE-372-94 to be furnished with the solicitation. Work is for Chrome Lines #1 and #2 Ventilation Systems, installation/repair/upgrade. Chrome Line #2 shall be complete and running before work commences on Chrome Line #1. Work includes removal of all fire damaged components of an existing Chrome Line #2 ventilation system to include FRP ductwork, demister, FRP fan, piping, electrical components; excavating area around both Chrome Lines #1 and #2 exhaust ductwork that is presently underground; constructing two concrete pits; installing new PVC exhaust ductwork, demister, fan, plumbing, and all associated components on both Chrome Lines #1 and #2; removing one chrome plating vat and installing two chrome plating vats to include installing 2 rectifiers, ventilation, steam heated coils, etc. on Chrome Line #2; performing all necessary electrical work to support system; installing all plumbing associated with demisters; installing recycling system to include holding tanks, pumps, meters, reverse osmosis unit, and all associated plumbing as required to recycle demisters washdown water. Contractor shall run PVC pipe to each chrome plating vat on both Chrome Lines #1 and #2 to allow addition of make-up solution to vats as needed. Emissions from equipment shall meet both Clean Air Act 40 CFR 63 Subpart N, and California Air Pollution Control Regulations, Title 17. A list of other required publications follows: ASTM D1556-82, D1557-78, D2167-84, D2216-80, D2487-85, D2922-81, D2937-83, D3017-78, D4318-84; Fed. Spec. SS-S-1401B, and CCC-C-467C; NBS PS 1-74 and PS 58-73; ACI 211.1-81, 211.2-81, 301-84, 315-74, and 318-83; AISI Cold-Formed Steel Design Manual, Sep. 1980; ASTM A 185-79, A525-80a, A 615-79, A 616-79, A 617-79, C 31-87A, C 33-86, C 39-86, C 42-84a, C 78-84, C 94-86b, C 143-78, C 150-86, C 171-69, C 172-82, C 192-81, C 231-82, C 260-86, C 309-81, C 494-86, C 595-85, C 618-85, D 98-87, D 1751-73, D 1752-67, and E96-80; AWS D1.4-79; NRMCA Certification of Ready-Mixed Concrete Production Fac (Jan 76); TMMB Truck Mixer and Agitator Standards (Jan. 1, 1981); AMCA 99-72 and 210-74; American Conference of Gov Industrial Hygienists 13th Ed.; ASTM A120, A167, E84-76a, C582, D883, C581, D638, D790, D2583; Fed. Spec. WW-V-51E, and WW-V-54D; AABC National Standard for Field Measurements and Instrumentation; NEB Standards for Testing, Balancing, Adjusting of Environmental Systems; NFPA 91-1973; Fed. Std. 141-A; SSPR SP-6-63; SMACNA Publications; Fed. Spec. J-C-30A, L-C-530B, L-P-1035A, L-T-0075, L-5-1512A, W-C-582, W-C-586B, W-F-406B, W-F-408C, W-F-1814, W-J-800C, W-S-610c and Amn-1; W-S-865c and Int. am-2; CC-M-1807, HH-I-510d, HH-I-553c, HH-I-595c, WW-C-00540C, WW-C-563A, WW-C-566C, and WW-C-581D; Mil. Spec MIL-P-15147C; ANSI C97.1-1972; NEMA FU 1-1966, ICS-1970, and RN-1974; NFPA 70-1993; UL 50 and UL 508; Fed Spec TT-E-489G, TT-E-1593B and TT-P-38D. One Job to be performed at the Anniston Army Depot, Anniston, Alabama 36201, Building 114. Completion time to be within 240 calendar days after date of notice to proceed. All responsible sources may submit an offer which shall be considered. Requests for solicitation must be in writing and are acceptable by FAX at 205/235-6353. Telephone requests will not be acknowledged.(0081)

Loren Data Corp. http://www.ld.com (SYN# 0110 19950323\Z-0001.SOL)


Z - Maintenance, Repair or Alteration of Real Property Index Page