COMMERCE BUSINESS DAILY ISSUE OF march 27,1995 PSA#1311U. S. Army Engineer District, Savannah, ATTN: CESAS-EN-EA, P.O. Box 889
(31402-0889) or 100 W. Oglethorpe (31401-3640), Savannah, Georgia C -- UPGRADE DORMITORIES, FY-98, L.I. 3005000, ROBINS AFB, GA POC
Larry Davis at 912/652-5407. 1. CONTRACT INFORMATION: The Savannah
District, U.S. Army Corps of Engineers, requires the services of an
Architect-Engineer firm for site investigation, planning, engineering
studies, concept, preliminary design (option), final design (option),
and construction phase services (option) and Shop Drawing Review
(option). This will be a firm fixed price contract. The contract is
anticipated to be awarded in June 1995 and completed in June 1996. The
estimated construction cost range is $5,000,000.00 to $10,000,000.00.
This announcement is open to all firms regardless of size. Large
business offerors must identify subcontracting opportunities with small
business, women owned small business and small disadvantaged businesses
on SF 255. If selected the large business offeror will be required to
submit a small/small disadvantaged & women owned subcontracting plan in
accordance with FAR 52-219.9 and DFARS 219.704/705 as a part of the
Request for Proposal Package. The following subcontracting goals are
the minimum acceptable goals to be included in the subcontracting plan.
OF THE SUBCONTRACTED WORK, 60% to SMALL BUSINESS, 10% TO SMALL
DISADVANTAGED BUSINESS (A COMPOSITE of SMALL BUSINESS), 4% TO
WOMEN-OWNED BUSINESS (A COMPOSITE of SMALL BUSINESS). Large business
firms that intend to do any subcontracting must convey their intent to
meet the minimum subcontracting goals on the SF 255, Block 6. Written
justification must be provided if the minimum goals cannot be
provided. For additional information concerning SUBCONTRACTING PLAN
requirements, please contact Ms. Leila Hollis at 912/652-5105. ** 2.
PROJECT INFORMATION: Renovate four dormitories (bldgs 755, 756, 780,
and 781)and construct a Central Chilled Water Plant to serve all
dormitories, and parking to service the dormitory area. Renovation is
to include HVAC, fire protection, interior electrical, asbestos
removal, interior and exterior architectural, and standing-seam metal
roofs. ** 3. SELECTION CRITERIA: See Note 24 for general process. The
selection criteria in descending order of importance are: ** a.
Specialized experience in the type of work described in Project
Information. The estimates for this project shall be prepared using the
latest Version of MCACES Gold Software. The software and User's Manual
will be provided by the Savannah District free of charge to the
successful A-E. The drawings will be prepared using graphics created
via Intergraph Microstation 32 or Micro/Station PC (4.0) and/or
AutoCADD Version 11. All drawings delivered to the District that have
been created using AutoCADD Version 11 must be translated to .dgn
files. The Contractor shall possess the software to enable the full
translation of drawing files from .dwg to .dgn and vice versa. Before
final selection the preselection A-E's may be required to demonstrate
the above compatibility by reproducing a Government supplied standard
drawing and translating it to the Intergraph format above. The method
of translation must be thoroughly described and documented in Block 10
if the A-E does not have a Intergraph CADD System. The A-E selected
will be required to submit a Design Quality Assurance Plan concurrently
with their fee proposal. The information to be contained in this plan
will be furnished upon notification of selection. Firms responding to
this announcement are requested not to transmit this plan with their SF
255. This project must be designed using SI Metric design requirement.
Design drawings and design analysis will be in hard metric. Automated
Review Management System (ARMS) software will be used in review
process. The A-E will be required to have a modem or ftp internet
access to communicate with ARMS Central for file transfer. The software
and necessary training will be provided by the Corps at no charge. This
project will require the use of National Institute of Building Sciences
Construction Criteria Base (CCB) CD-ROM disks for the latest guide
specifications and specification editing software, SPECSINTACT.
Architect-Engineer firms will be required to have a current
subscription to CCB and a CD-ROM reader. ** b. Past performance on DoD
and other contracts with respect to cost control, quality of work, and
compliance with performance schedules. ** c. Capacity to provide staff
in the following disciplines: architect, civil engineer, structural
engineer, electrical engineer, mechanical engineer, an industrial
hygienist (asbestos) and topographic survey crew. The design team must
include a Registered Engineer or Registered Architect who is a full
''member'' in good standing of the Society of Fire Protection Engineers
(SFPE) or an individual who is a registered Fire Protection Engineer
and whose principal duties are Fire Protection Engineering. ** d.
Professional qualifications of key management and professional staff
members. ** e. Extent of participation of SB, SDB, WOB, historically
black colleges and university and minority institutions in the proposed
contract team, measured as a percentage of the estimated effort. ** f.
Geographic location will not be a consideration in this selection. **
g. Volume of DoD contract awards in the last 12 months as described in
Note 24. ** 4. SUBMITTAL REQUIREMENTS: Firms desiring consideration
must submit ONE (1) copy of SF 255 (revised 11/92) for prime and ONE
(1) copy of SF 254 (revised 11/92) for prime and each consultant to the
above address by 24 April 1995 to be considered for selection. DEPTH of
Prime and SUBCONTRACTOR personnel in EACH discipline must be shown in
Block 4 of SF 255 and SF 254 to clearly identify the number of
personnel in each firm and discipline. COVER letters and extraneous
materials are NOT desired and WILL NOT be considered. ** PHONE calls
are DISCOURAGED unless absolutely necessary. Personal visits for the
PURPOSE of DISCUSSING this ANNOUNCEMENT will not be SCHEDULED. THIS is
NOT a REQUEST for a PROPOSAL. (0082) Loren Data Corp. http://www.ld.com (SYN# 0021 19950324\C-0011.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|