|
COMMERCE BUSINESS DAILY ISSUE OF march 27,1995 PSA#131112th CONTRACTING SQUADRON/LGCC, 395 B STREET WEST, RANDOLPH AFB TX
78150-4525 Attn:HWD/Mr Philip Kirby C -- A/E SERVICES IDQ FOR MECH AND ELECT PROJECTS, RANDOLPH AFB, TX
POC Mr Philip Kirby tel: 210/652-5183 CNT F41691-95-R-0028 TITLE I AND
TITLE II SERVICES FOR MECHANICAL/ELECTRICAL PROJECTS at Randolph AFB
to be issued under this contract are required. Computer Aided Design
and Drafting (CADD) capability and compatibility with AutoCADD Release
11 and capability to digitize existing drawings for CADD use are also
required. Delivery Orders will consist of but not limited to: (1)
Making Technical Studies, Analyses, Surveys, Investigations, and
Reports; (2) Planning of Site Developments and Installations: (3)
Supervising and Inspecting Maintenance, Repair, and Construction
Projects; and (4) Performing the necessary supervision and coordination
of all phases of A-E work. One indefinite quantity contract will be
awarded. The contractor is guaranteed a minimum of $5,000 in fees for
one year. No individual delivery order will be more than $299,000 in
fees and the total of all delivery order fees will not exceed $750,000
per contract year. Also, an option to extend the awarded contract for
1 year, is a part of this announcement. Services may require single or
all disciplines with primarily Electrical/Mechanical Engineering
Requirements. This procurement will be from Appropriated Funds and will
be a Negotiated Firm Fixed-Price Contract. Estimated Start Date is Jul
95 with services required through Jul 96. All responses received
within 30 days after this publication will be considered for selection
Small business concerns and small disadvantage business concerns are
encouraged to respond to this announcement. Evaluation Criteria in
relative order of importance to be used for selection of the A-E Firm
(ATC Form 319, Modified): (1) Specialized experience demonstating
ability in past professional work of similar nature, CADD Capability
and Compatibility with AutoCADD and capability to digitize existing
drawings for CADD Use. (2) Professional Qualifications of the staff to
be assigned to the project. (3) Professional capacity to accomplish
the work within anticipated schedule. (4) Past Performance with respect
to execution of both DOD and Non-DOD Contracts. (5) Location within 250
Mile Radius of San Antonio or within 1 hour by Air Travel with priority
for local firms provided an appropriate number of qualified firms are
available. (6) Dollar Value of DOD work awarded for the 3 years
preceding date of this synopsis. In addition to the above, each firm
will indicate as selected consultants to include but not limited to the
following design disciplines: (A) Architectural (including Landscape
Architects). (B) Civil Engineer (General plus Airfield design), (C)
Structrual, (D) Mechanical (primarily HVAC and Plumbing), (E)
Environmantal (Hazardous Waste Identification and Design) and (F)
Electrical (Building Design, Exterior Lighting and Underground
Distribution). Either through Consultants, Joint Ventures or complete
In-House Capability of the listed design disciplines is acceptable. In
addition each firm musT4s@6S- (f)Mohave CADD Capability either
In-House or through the use of consultants.E?mm3{ Firms desiring
consideration shall submit appropriate data as described in Numbered
Note 24, including Standard Forms 254 (Architect Engineer Related
Services Questionnaire and 255 (Architect-Engineer and Related Services
Questionnaire for specific Projects) to 12 CES/CECC-1, Attention:
Jessica Villarreal, 1651 5th Street West, Randolph AFB TX 78150-4513.
(0082) Loren Data Corp. http://www.ld.com (SYN# 0023 19950324\C-0013.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|