COMMERCE BUSINESS DAILY ISSUE OF APRIL 5,1995 PSA#1318US Army CECOM, Product Integrity & Production Engineering Directorate,
Fort Monmouth, NJ 07703-5000 59 -- MARKET SURVEY FOR MILITARY POWER SUPPLY FROM CURRENTLY QUALIFIED
SOURCES DUE 041795 POC Jeffery Potter, Electronics Engineer, (908)
532-5733. This is a market survey to determine the availability of
Military power supplies from sources that are currently CECOM qualified
for this item. The following are criteria which prospective suppliers
must have PREVIOUSLY successfully demonstrated to CECOM. a) Must match
form, fit and function with power supply PP-7462A/U at unit level. b)
The power supply has met the +55 degree F to + 95 degree F operating
temperatures and -62 degree C to +70 degree C non-operating
temperatures; c) The power supply has met the vehicular transportation
and railroad transportation test specified in paragraphs 3.5 and 3.6
of MIL-S-55562(CR); d) The power supply has met the humidity test of
MIL-STD-810C, Method 507.1, Procedure II, under non-operating
conditions. Please note: this test is performed with the power supply
in the semi-trailer or an equivalent enclosure (same number of cubic
feet) with the air vents in the open position; e) INPUTS: 187-229
volts, 200-245 volts, 400-490 volts, 60 Hertz, or 380 volts, 50 Hertz;
104 Amperes at 230 volts input (max), 52 Amperes at 460 volts input
(max), 3 phase; f) OUTPUT: 28 Volts DC (nominal), 26-36 volts
Adjustment Range for 60 Hertz operation, 28-31 volts Adjustment Range
for 50 Hertz operation; 500 Amperes continuous; g) OUTPUT CURRENT
REGULATION: Static plus or minus 0.25%, Dynamic 5 volts at 1/2 load, 8
volts at full load; h) WEIGHT: 720 lbs (max); i) DIMENSIONS: 23 1/2''
wide (max) by 25'' deep (max) by 38 3/4'' high (max). Deliveries will
be required to be completed by the end of September 1995. Inquiries
pertaining to this correspondence should be directed to Mr. Jeffery
Potter, (908) 532-5733 or DSN 992-5733, FAX No. (908) 532-3901. Written
communications should be addressed to Commander, U.S. Army
Communications-Electronics Command and Fort Monmouth, ATTN:
AMSEL-LC-ED-MX-3, Fort Monmouth, NJ 07703-5023. E-Mail Address:
AMSEL-LC-ED-M@cecom3.monmouth.army.mil. The deadline for response to
this notice is April 17, 1995. (0093) Loren Data Corp. http://www.ld.com (SYN# 0388 19950404\59-0021.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|