COMMERCE BUSINESS DAILY ISSUE OF APRIL 17, 1995 PSA#1326OPTEC Contracting Activity, Attn: CSTE-ZOC, Bldg 91025 P.O. Box Y, West
Fort Hood, TX 76544-5056 59 -- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS SOL
DATM01-95-R-0021 due 042895. Contact Shirley Hayes, Contract
Specialist, (817) 288-9578 or Theodore H. Panknin, (817) 288-9565. This
synopsis amends the previous synopsis published 16 Dec 94, for 12 each
broadband, linear, solid state amplifiers. The solicitation number has
been changed from DATM01-95-R-0007 to DATM01-95-R-0021. The
specifications have been changed in the following areas: The frequency
range is changed from of 20 - 500 MHz to 20 - 1000 MHZ, with minimum
output power of 100 watts. The small signal gainflatness is changed
from +-1dB to +-2dB. The weight is changed from 70 pounds maximum to
100 pounds maximum. The maximum height is changed from 8 inches to 12
inches. All other previous published specifications will remain the
same as outlined below. The Automated Intelligence/Electronic Warfare
Test System (AI/EWTS) provides target threat communications signals for
the testing of U.S. Intelligence and Electronic Warfare systems. The
amplifiers will be the final amplification stage for transmitting
digital and analog signal modulations. The contractor shall not provide
racks, any of the signal sources mentioned below, nor do any
installation. Each amplifer will be installed in an equipment rack in
an air conditioned step van typically powered by an onboard generator.
The step van will be driven over graded roads, at altitudes of up to
10,000 feet, incold and hot climates, and relative humidity of up to
95%. The types of signals to be transmitted would include narrow (less
than 10 microsecond (us)) pulses, swept (greater than 0.1 MHz/us)
signals, and 100% duty cycle broad bandwidth (greater than 10 MHz)
noise (by frequency modulation) at full power. The driving signal
source will typcially be leveled (0 dBm), cannot exceed +13 dBm, and
might jump in frequency rapidly (i.e., jump from 20 MHz where the
amplifier was at full power, change to 100 MHz and turn on to full
power in about 5 us). The typical load it can be expected to operate
into is a VHF log periodic antenna whose Voltage Standing Wave Ratio
(VSWR) is 1.2:1 at midband but whose VSWR might exceed 8.0:1 at band
edges. It is required that if a high VSWR (greater than 9.0:1) is
encountered, the amplifier not trip and need resetting but remain
operated (at reduced forward power). In the event the RF output is
accidently open or shorted, and primary power and drive applied, no
damage shall result to the amplifier; The Government's requirements
are: Amplifier Power supply(s) All interconnecting cables required for
operation. Operation/maintenance manual(s). Schematics and parts list
for electronic maintenance. Any special tools (such as extender boards
or special cables) for maintenance. Rack mount hardware. Plan for
factory test. Factory test results. All solid state construction in
accordance with best commercial practice. The unit shall incorporate
connectorized modules for field maintenance and repair of the
amplifier; Mode of Operation: Class A or AB linear; Temperature Range:
0 degree to 50 degree C ambient operating, -20 degree to 60 degree C
storage. Frequency Range: 20 to 1000 MHz, 480 MHz instantaneous
bandwidth. Output Power: 100 watts minimum into a 1.2:1 VSWR load at
any frequency within the operating frequency range. Gain: 50 dB
minimum, it is desirable to reach full power with 0 dBm drive; Small
Signal Gain Flatness: +-2 dB; Input Protection: +13 dBm with no damage;
Input/Output Impedance: 50 OHMS nominal; Input VSWR: 2.0:1 maximum;
Non-Damage Loading; Shall operate into any load (including open and
short) without damage; Operating Load: At least 9.0:1 VSWR without trip
(only the output power is reduced) Harmonics at rated Output: -20 dBc
(2nd), -12 dBc (3rd); Dynamic Range: 50 dB minimum; Spurious Signals at
Rated Output: -60 dBc; Primary Power: 110 to 120 VAC, 50/60 Hz, single
phase; Indicators: Power on, Thermal Overload, VSWR, Fault; Output
Protection: Thermal overload, load VSWR, input overdrive, overvoltage,
undervoltage, overcurrent; Cooling, Air, Connectors: Type N female RF
out, Type N female RF in. All connectors mounted at chassis rear; Rack
Slides: Provide for each amplifier Handles: Provided for each
amplifier; AC Power Cable: Separate cord, 4 foot minimum with standard
IEC 320 power line connector into the amplifier; Weight: 100 pounds
maximum; Size Overall: Fits standard 19 inch equipment rack, 27 inch
depth, 12-inch height maximum; Output Pulse Rise Time to Rated Peak
Power: 2 uS max; Output Pulse Fall Time From Rated Output Power to
Cutoff; 1 uS ma; Swept Output at Rated Power: Carrier input shall be
swept from 20.0 to 500.0 MHz in no more than 4800 uS and at a constant
9 dBm level. The output shall not be less than rated power over the
specified frequency range except at band edges. When swept at a much
slower rate (48 seconds over 480 MHz) no oscillations shall be observed
under any load. Delivery to Fort Huachuca, Arizona. A request for a
copy of the solicitation and amendments shall be done by facsimile,
(817) 288-9522 or by mail. The Standard Industrial Code is 3663. See
Note 1. (101) Loren Data Corp. http://www.ld.com (SYN# 0329 19950414\59-0001.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|