Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 18,1995 PSA#1327

Southwest Division, Code 0212, Naval Facilities Engineering Command, 1220 Pacific Highway, Room 135, San Diego, CA 92132-5187

Y -- AIRFIELD COMMUNICATIONS AND ELECTRICAL INFRASTRUCTURE UPGRADES (P-004) AT MARINE CORPS AIR STATION, CAMP PENDLETON, CALIFORNIA SOL N68711-93-B-1444 DUE 061695 POC For Plans and Specs info call 619-532-2082/Contract Specialist, Rowena Galendez/Contracting Officer, Janet Buyson/Bid Results, 619- 532-2355. --The work includes construction of concrete ductbanks with all manholes, handholes and conduits to support the communication and electrical system at the air station. Airfield lighting cables and 15kV power cables will be provided for reconnection to all existing air field lighting equipment and three incoming primary services. The communication/electrical ductbank will be routed south of the air station parallel to Vandergrift Boulevard, and interconnected from the east to west via a manhole system. The airfield lighting ductbank will begin at the airfield lighting vault and routed around the runway. The weather and radar ductbank will be routed from the control tower and terminated at its respective equipment in the airfield for future reconnection. The proposed electrical system will be a looped primary distribution system with nine interconnecting sectionalizing switches for quick isolation fault and restoration of primary service complete and ready for use.--The estimated cost is between $5,000,000 and $10,000,000.--Firm Fixed Price Contract.--Contract duration is 270 calendar days.--Bids will be considered from all responsible sources.--This project is unrestricted.--The Standard Industrial Code is 1731 and the annual size standard is $7 million.--It is recommended the subcontracting plan goals reflect a minimum goal of 5% for Small Disadvantaged Business subcontracting effort.--NOTE: Plans and specs will not be mailed to firms within a 20 mile radius of the issuing office.--Solicitation packages may be acquired in person from Plan Issue or by mail.--Telephone requests will not be accepted.--Requests for the solicitation package must be in writing stating solicitation number N68711-93-B-1444, complete name, address, area code and phone number and whether bidding as a prime/subcontractor/supplier.--Plan holders lists will not be faxed.--Mail requests to Southwest Division, Naval Facilities Engineering Command (Plan Issue), Building 132, 1220 Pacific Highway, San Diego, CA 92132-5187 or fax requests to Plan Issue at (619) 532-2083.--Plans and specifications will be available on or about 16 May 1995 until supply is exhausted.--No deposit required. (0104)

Loren Data Corp. http://www.ld.com (SYN# 0092 19950417\Y-0006.SOL)


Y - Construction of Structures and Facilities Index Page