COMMERCE BUSINESS DAILY ISSUE OF APRIL 21,1995 PSA#1330National Institute of Standards and Technology, Acquisition and
Assistance Division, Bldg. 301, Room B117, Gaithersburg, MD 20899 66 -- ISCO SFX 3560 SUPERCRITICAL FLUID EXTRACTION APPARATUS SOL
52SBNB5C8668 DUE 051795 POC Stacy Bostjanick The National Institute of
Standards and Technology (NIST) intends to negotiate on a sole source
basis under the authority of 41 USC 253(C)(1). The supplies and
services required by the Agency are available from only one responsible
source and no other supplier will satisfy the needs of the Agency. It
is anticipated to negotiate with the sole manufacturer, ISCO, Inc.
Lincoln, NE for a Pump Module with cooling jacket. The Pump module
shall be compatible with the NIST owned ISCO 100D Syringe Pump and Pump
Controller. The Pump Module shall also meet the following requirements:
Fully automated SFE system for sequential unattended extraction of 1 to
24 samples under user-programmed control via built-in microprocessor
controller, System must be equipped for programmable cryogenic liquid
trapping of analytes from ambient temperature to at least -20 degrees
C and collection pressure of 30 psi, System must include temperature
programmable shielded coaxial restrictor with temperature range of
ambient to 240 degrees C, System must allow static and dynamic
extraction, temperature, pressure, and time programming for each
sample, Syringe pump with at least 260 mL volume, pressure of 7,500 psi
(500 atm) and flow rate of 1 muL to 90 mL/min, or at least 100 mL
volume, pressure of 10,000 psi (700 atm) and flow rate of 0.1 muL to 25
mL/min, Programmable extraction temperature from ambient to at least
150 degrees C, Pressure-rated for 10,000 psi (700 atm), Programmable
fluid line wash with CO Sub 2 or CO Sub 2 /modifier, Extraction vessels
from 0.5 to 10 mL with fingertight caps, System must perform
extractions using downward flow of supercritical solvent, Dynamic
modifier addition programmable up to 10,000 psi and 0-50% v/v, System
must provide full programmable control from front panel keypad for;
extraction pressure, temperature, flow, time, and modifier addition,
and Collection module must include removable analyte collection reel
(24 samples and blank) with provision for collecting in vial sizes of
125 X 20 mm OD. The aforementioned manufacturer is the only known
source of this product.-- Interested offerors may identify their
interest and capability to respond to the requirements by submitting a
capability statement. The capability statement must provide adequate
information to allow evaluation to provide the Pump Module. All of the
above must be provided for the Government to consider whether to open
this requirement for competition. This notice of intent is not a
request for competitive proposals. However, all ''compatibility
statements'' received within 45 days after the date of this publication
in the Commerce Business Daily will be considered by the Government. A
solicitation is not available. See Numbered Note 22. (0109) Loren Data Corp. http://www.ld.com (SYN# 0271 19950420\66-0005.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|