Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 25,1995 PSA#1332

AFDTC/PKO, 205 West D Ave, Ste 541, Eglin AFB FL 32542-6862

66 -- 66-EMI (ELECTROMAGNETIC INTERFERENCE)/EMC (ELECTROMAGNETIC CAPABILITY) RECEIVER SOL F08651-95-B-0102 DUE 051295 POC Contact C. Delgado, 904-882-8583, Contract Specialist; Contracting Officer, Bonnie J. Fitch. The Air Force Development Test Center (AFDTC) intends to acquire competitively one each EMI/EMC Receiver. The test apparatus will be required to produce reliable test results that meet the requirements of the Jan 1993, and previous versions of, MIL-STD-461D, Electromagnetic Emission and Susceptibilty Requirements for the Control of Electromagnetic Interference. The test apparatus must also meet the regulations for International Special Committee on Radio Interference (CISPR), Verband Deutscher Elektrotechniker (VDE) and Federal Communications Commission (FCC). The items shall not require non-recurring engineering and will be off-the-shelf products to conduct EMI and Electromagnetic Compatibity (EMC) system level test integration. The specific areas of system level testing that are required by the MIL-STDs-461 include conducted emissions (CE), radiated emissions (RE), conducted susceptibility (CS), and radiated susceptibility (RS) test prodedures and methods. The following items listed will be required to meet the government requirement to upgrade the Pre-Flight Integration of Munitions and Electronics Systems (PRIMES) facility to certify and become an accredited EMI/EMC national laboratory by completing the National Laboratory Accreditation Program (NVLAP). The items listed will be compatible and connected with the existing PRIMES EMI/EMC software and hardware. Minimum electrical specifications include the frequency range (30 Hz to 18 GHz), resolution bandwidths, rf attenuation, passband frequencies, tracking generation, compression points, and parallel detection capability specified in MIL-STDs-461. Minimum software requirements include automated testing with Macro capability and MIL library functions with built-in transducer tables and limit lines. Display of near real-time spectrum is required. Items required: EMI test receiver, windows based software for EMI test receiver, software driver for EMI test receiver, and script development kit. Required delivery is 120 days after award of contract. Technical questions may be directed to Kathy Render at 904-882-9354 and will be accepted only until issuance of the solicitation. After the solicitation is issued, all technical questions must be in writing and directed to the Contracting Office/AFDTC/PKOS. A solicitation has not yet been prepared for this acquisition. Replies to this synopsis should be provided to AFDTC/PKOS, 205 W D Ave Suite 541, Eglin AFB FL 32542-6862. All responsible sources may submit a bid which will be considered. (No contract award will be made on the basis of bids/proposals received in response to this synopsis.) Firms responding to this solicitation should reference F08651-95-B-0102 and indicate whether they are or are not a small or small disadvantaged business concern as defined in FAR 52.219-1 and 52.219-2 and whether they are a manufacturer or dealer/distributor. The Air Force reserves the right to consider a small business set-aside based on responses hereto. Requests for copies of this solicitation must be in writing and can be faxed to 904-882-9442 or 904-882-4129. Telephone requests will not be accepted. See Note 12. (0111)

Loren Data Corp. http://www.ld.com (SYN# 0315 19950424\66-0001.SOL)


66 - Instruments and Laboratory Equipment Index Page