COMMERCE BUSINESS DAILY ISSUE OF MAY 10,1995 PSA#1343Naval Research Laboratory, Attn: Code 3220.CR 4555 Overlook Avenue, SW
Washington, DC 20375-5326 66 -- SHORT PULSED LASER PLASMA SYSTEM SOL N00014-95-R-CR11 POC Alan
W. Crupi, Contract Specialist, Code 3220.CR, (202) 767-2550 and Wayne
Carrington, Contracting Officer, Code 3220.WC. The Naval Research
Laboratory (NRL) has a requirement for one (1) each short pulsed laser
system. The laser system consists of a CW diode pumped actively mode
locked Nd-YLF oscillator, a Nd-YLF regenerative amplifier and a fourth
harmonic conversion system. The laser system must meet the following
minimum specifications: Fundamental wavelength 1053 nm, minimum energy
output for CW oscillator: 2 nJ/pulse, repetition rate of CW
oscillator: 100 Mhz (+/- 10%), spatial mode from oscillator: TEMOO,
minimum energy output from amplified output at 1053 nm: 2 mJ, pulse to
pulse energy stability of amplified output at 1053 nm: better than 5%
rms, minimum contract between selected pulse from regenerative
amplifier and adjacent pulses: 100 : 1, the amplified 1053 nm pulse
must have a FWHM angular divergence that is no larger than 2x that
limited by diffraction, maximum pulse width FWHM from oscillator: 10
psec, maximum pulse width FWHM after amplification to 2 mJ at 1053 nm:
15 psec, minimum energy output at fourth harmonic: 0.5mJ, Trigger
operation: A 5v trigger will be available for rough synchronization of
the regenerative amplifier system to a second trigger. The optical
output must have less than 20 nsec jitter with respect to this external
trigger. The system must provide a synchronized trigger output ()5v,
(10 nsec risetime) that occurs a minimum of 2 microseconds prior to the
optical pulse output of the regenerative amplifier that has less than
0.5 nsec rms jitter with respect to the optical pulse output. The
regenerative amplifier must meet single shot and at a minimum of 2Hz.
The system must have a minimum of a one year warranty. FOB destination,
required delivery is 90 days after receiving order. The solicitation
will close 30 days after issuance of the RFP. All responsible sources
may submit an offer which shall be considered. Telephone requests for
this solicitation will not be honored. Send requests for solicitation
to: Contracting Officer, Attn: Code: 3220.CR, Naval Research
Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375- 5326.
Facsimile requests may be sent to (202) 767-5896/6197. Reference
Synopsis CR11. See numbered Note 1. (0128) Loren Data Corp. http://www.ld.com (SYN# 0252 19950509\66-0005.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|