|
COMMERCE BUSINESS DAILY ISSUE OF may 25,1995 PSA#1354Commanding Officer (B340), Marine Corps Logistics Base, Contracting and
Purchasing, Box 110340, Barstow, CA 92311-5039 66 -- LABORATORY EQUIPMENT SOL M6220495BA008. DUE 071395. Contact
Annie Branch, (619) 577-6246, FAX: (619) 577-6174. PH and Temperature
Measurement Meter with Kit, 115V, 50/60Hz, and 0.1 Amp electrical
connection. ATC probe is included. Minimum Ranges are 10 to the -9
power to 9.99x10 to the 9 power ion, -2 to +20 PH, and plus/minus
1800mV. The relative accuracy is minimum of plus/minus 0.17n% for ion,
plus/minus 0.002 for PH and plus/minus 0.1 for mV. Temperature
measurement and control is from -5.0 degrees to +105 degrees Centigrade
minimum. Salinity range are from 0 to 70ppt NaCL equivalent
(autoranging), or 0 to 40ppt practical. Fisher Scientific cat no.
13-635-50, 3 ea. Visible Range Spectrophotometer, (200-1100mm), split
beam type with a 5mm spectral slit width. Wavelength range of 100 to
900nm, minimum accuracy of plus/minus 1nm, with minimum precision of
plus/minus 0.5nm; the minimum photometric range is -0.1 to 3.0A with a
to 125% T. minimum accuracy is plus/minus 0.003A from 0 to 0.3A;
plus/minus 1% of reading from 0.3A to 2A; and plus/minus 2% of reading
from 2A to 3A. Deuterium and tungsten-halogen source lamp. Milton Roy
P/N 33-60-01, 1 ea. Analytical Balance, accuracy plus/minus .0001gm
minimum, 115 or 230V. Weighing Range of at least 0 to 405 gm, size of
17'' x 9.5'' x 11'' with a tolerance of plus/minus 2 inches in each
dimension. Mettler Toledo model # AT400, 1 ea. Total Organic Halide
(TOX) Analyzer consisting of a microprocessor controlled analyzer for
sample preparation. The analyzer must meet criteria for EPA 450.1 &
Standard Method 5320 (AWWA 18th Edition), dual zone combustion furnace
with a max temp of 1200 degrees centigrade; integrated microprocessor,
floppy disk drive and VGA monitor, built-in printer with optional
automatic printing of results, external printer port & separate
external COM port, 1 ea. Atomic absorption spectrophotometer for
analysis of cadmium, chromium, copper, lead, nickel, silver & zinc. The
unit must have 2 power supplies, AA software must be DOS based and
nickel alloy burner heed, 1 ea. Volatile Organics Gas Chromatograph
System, a pre-configured package, which must include a gas
chromatograph, purge-and-trap assembly, PID/E1CD detectors, data
acquisition/reduction system, field installation, quality assurance
checkout and familiarization training, must be able to perform at a
minimum, EPA methods 601, 602, 8010, and 8020, 1 ea. Total Organic
Carbon (TOC) Analyzer, range of 4ppb carbon for TOC to 10,000ppm carbon
for POC, equipped with printer which reports time of analysis, sample
number, & concentration of the sample in parts per million, 1 ea. All
items to be delivered to Marine Corps Logistics Base, Barstow, CA. All
responsible sources may submit a bid which shall be considered. All
solicitation requests must be in writing. (142) Loren Data Corp. http://www.ld.com (SYN# 0377 19950524\66-0001.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|